Order Data
Model No. | Specification | Order No. |
H35-00 | CTH300-H standard CPU, 192KB PM, 512KB DM,16KB data stored when power down, 2 PPI/Free port, 1 EtherNET port, 1 USB port. | CTH3 H35-000S1 |
H36-00 | CTH300-H standard CPU, 256KB PM, 1MB DM,32KB data stored when power down, 1 PPI/Free port, 1 EtherNET port,1 EtherCAT port, 1 USB port. | CTH3 H36-000S1 |
H36-01 | CTH300-H standard CPU, 256KB PM, 1MB DM,32KB data stored when power down, 1 PPI/Free port, 1 EtherNET port,1 EtherCAT port, 1 USB port.(Recommend) | CTH3 H36-001S2 |
Performance Parameters
Physical features | ||||
Dimension(W×H×D) | 34×115×101.6 mm | |||
Power dissipation | 19.5W | |||
Power supply features | ||||
Rated input voltage | 24V DC | |||
Input voltage range | 20.4~28.8V DC | |||
Input current | 0.8A | |||
Reverse polarity protection | Yes | |||
Bus power supply voltage | +5V DC | |||
Bus supply current | 1.6A | |||
LED indicator characteristics | ||||
24V power indicator (green) | On: 24VDC power supply is normal, off: no 24VDC power supply | |||
SF indicator (red) | On: system failure, off: no error | |||
BF indicator (red) | On: bus failure, off: no error | |||
FRCE indicator (yellow) | On: items are forced, Off: no items are forced.< note > can also be controlled via the scrapers command. | |||
RMC indicator (green) | On: CPU has successfully communicated with the remote server (dial switch 3 is ON and Ethernet port parameters have been configured correctly) Off: CPU fails to communicate with the remote server or disallows communication with the remote server (allows and disallows communication with the server via dialing switch) | |||
Run indicator (green) | On:system runs, off: the system stops | |||
STOP indicator(orange) | On: system stops; Off: system runs | |||
Ethernet indicator | Green | Flicker: connected, out: unconnected | ||
Yellow | On:100Mbps,Off:10Mbps | |||
Expand I/O capabilities | ||||
Maximum number of racks of 1CPU | 4 | |||
Maximum number of modules supported per rack | Support up to 8 modules except power, CPU, relay module | |||
Function category | Feature | Describe | ||
Communication function | Bus interface | Provides an extension module interface | ||
USB port | Provide a USB main device interface | |||
Standard Ethernet interface | 1 Ethernet interface is provided ® supports Ethernet programming; ® supports UDP_PPI protocol: network read and write operation between CPUs (instruction mode UDPNETW/UDPNETR or instruction wizard mode); ® supports Modbus_TCP protocol; | |||
RS485 port | H35-00:2*RS485 port H36-00/H36-01:1*RS485 port | |||
EtherCAT port | H35-00:None H36-00/H36-01:1*EtherCAT port | |||
CANopen port | H35-00/H36-00:None H36-01:1*CANopen port | |||
Storage capabilities | Program memory | H35-00:192KB;H36-00/H36-01:256KB | ||
Data storage | H35-00:512KB;H36-00/H36-01:1MB | |||
Power down to maintain data | H35-00:16KB;H36-00/H36-01:32KB | |||
Expand I/O capabilities | Expand function | Maximum expansion of 32 I/O modules (4 racks, 8 modules per rack) | ||
Isolation function | Power supply isolation | Isolation between external power and system power | ||
Communication isolation | EtherNET、EtherCAT、RS485、CANopen isolation | |||
Protection function | Power protection | Power supply end provides reverse connection protection function and surge absorption function | ||
Interface protection | Communication port lightning protection | |||
Programming function | Programming function | MagicWorks PLC provides LAD ladder diagram, instruction list STL two programming languages, programming software support Chinese/English. | ||
Run switch | RUN/STOP | Reset IP configuration by flipping the switch five times within 3 seconds (RUN from run-> STOP, RUN from stop-bbb> | ||
PORT0:RS485 port | |||
Number of communication ports and protocols | RS485 port(switchable PPI and free port protocol) | ||
Communication baud rate | PPI/MPI:9.6Kbps、19.2Kbps、187.5Kbps | ||
Free port :1.2Kbps~115.2Kbps,built-in Modbus master/slave function | |||
Maximum cable length per segment | Use isolation repeater: 1000m (187.5kbps) 1200m(38.4Kbps) No isolation repeater: 50M | ||
Maximum number of stations | Each segment with 32 stations and each network with 126 stations | ||
Point to point (PPI main station mode) | Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time | ||
MPI connection | A MPI slave station can connect up to 8 MPI masters | ||
Isolation | Communication port isolation | ||
RJ45 port | |||
Communication protocol | H35-00 | H36-00/H36-01 | H36-01 |
PPI/MPI、 free port (Modbus RTU) | EtherCAT | CANopen | |
Communication baud rate | PPI/MPI:9.6Kbps、19.2Kbps、187.5Kbps | 100Mbps | 20Kbps~1Mbps |
Free port:1.2Kbps~115.2Kbps | |||
Maximum cable length per segment | Use isolation repeater: 1000m (187.5kbps) 1200m(38.4Kbps) No isolation repeater: 50M | 100m connection | Maximum 2500 m (20Kbps) Minimum 25m (1Mbps) Refer to CANopen communication port |
Maximum number of stations | Each segment with 32 stations and each network with 126 stations | No limit | Each master station support a maximum of 32 slaves |
Point to point (PPI main station mode) | Yes (NETR/NETW), each instruction is up to 200 bytes read/write, 8 read/write instructions are allowed at a time | -- | -- |
MPI connection | A MPI slave station can connect up to 8 MPI masters | -- | -- |
Isolation | Communication port isolation | ||
EtherNET port | |||
Communication port | 1*EtherNET port | ||
Baud rate | 10/100Mbps adaptive | ||
Protocol types | Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support Ethernet programming and Ethernet communication between CPU | ||
Maximum length of each cable | 100m directly connected | ||
Maximum number of connections per site | UDP_PPI supports a maximum of 8 connections, modbus_TCP supports a maximum of 32 connections, Socket supports a maximum of 4 connections, 2 UDP, 2 TCP | ||
| Quantity of user data | Up to 200 bytes for UDP_PPI transfer, Up to 240 bytes for ModBus_TCP transmission, A maximum of 512 bytes are used for Socket transmission | ||
DHCP function | Support | ||
Remote monitoring/programming | Support | ||
Isolation | Communication port isolation | ||
CANopen port | ||||||||
Communication port | -- | 1*CAN port | ||||||
Maximum number of slave stations | 1 master station can be connected maximum of 32 slave stations | |||||||
Protocol types | CANopen DS301standard protocol | |||||||
Support functions | Supports automatic starting of CANopen Manager | |||||||
Supports optional slave polling | ||||||||
Support to start slave stations | ||||||||
Support NMT | ||||||||
Support synchronous production | ||||||||
Support synchronous consumption | ||||||||
Support heartbeat generation | ||||||||
Support activation time creation | ||||||||
Transmission rate(kbit/s) | 1000 | 800 | 500 | 250 | 125 | 50 | 20 | |
Maximum length(m) | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 | |
Isolation | Communication port isolation | |||||||
Power interface definition
4pin terminals spaced at 3.81mm apart | Symbol | Signal definition |
| L+ | +24V power |
M | +24V power ground | |
| Ground | |
-- | -- |
USB interface definition
USB port | No. | Signal | Signal definition |
![]() | 1 | V_BUS | +5V power |
2 | Data- | Data- | |
3 | Data+ | Data+ | |
4 | GND | Ground |
EtherNET interface definition
RJ45 port | No. | Signal | Signal definition |
| 1 | TX+ | Positive end of data transmission |
2 | TX- | Negative end of data transmission | |
3 | RX+ | Positive end of data transmission | |
4 | TERM | -- | |
5 | TERM | -- | |
6 | RX- | Negative end of data transmission | |
7 | TERM | -- | |
8 | TERM | -- | |
Shell | PE | Shell ground | |
Green indicator | As an indication of EtherNET connection status | ||
Yellow indicator | As an indication of EtherNET connection status | ||
CAN interface definition
RJ45 port | No. | Signal | Signal definition |
![]() | 1 | CAN_H | Positive end of data transmission |
2 | CAN_L | Negative end of data transmission | |
3 | -- | -- | |
4 | -- | -- | |
5 | -- | -- | |
6 | -- | -- | |
7 | CAN_GND | CAN Gound | |
8 | -- | -- | |
| Shell | PE | Shell ground | |
| Green indicator | As an indication of CAN connection status | ||
| Yellow indicator | As an indication of CAN connection status | ||
RS485 interface definition
Port0,use 2pcs of 3pin terminals spaced at 3.81mm apart | ||
6pin terminals | Signal | Signal definition |
| A0 | PORT0 RS485 signal A |
B0 | PORT0 RS485 signal B | |
SG | PORT0 RS485 signal ground | |
A0 | PORT0 RS485 signal A | |
B0 | PORT0 RS485 signal B | |
SG | PORT0 RS485 signal ground | |
Dial switch definition
Dial switch | Symbol | Dial direction | Signal definition |
| RUN | Up | System operation |
STOP | Down | System halt | |
Swivel 5 times in 3 seconds | Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |
DIP dial | No. | Symbol | Signal definition | Note |
| 1 | Term-PORT0 | Terminal resistance switch 1(PORT0) | ON:with terminal resistance OFF:without terminal resistance |
2 | Term-PORT1 (H35-00) | Terminal resistance switch 2(PORT1) | ON:with terminal resistance OFF:without terminal resistance | |
NC (H36-00/H36-01) | -- | -- | ||
3 | RMC-SW | Remote control switch | ON:Remote control allow OFF:Remote control forbid |