Order Data
Model No. | Series | Specification | Order No. |
H56-10 | CTH-300 | H56-10 motion controller:256KBKB PM,1MB DM,32KB DM when power down,24VDC power supply,10DI,6*500KHz high-speed counter,1*EtherNET port.1*USB port,1*CAN port,1*EtherCAT port,1*RS485 port.Support single-axis motion control functions, support interpolation, support electronic CAM and electronic gear and other functions, support C language programming. | CTH3 H56-100S2 |
Performance Parameters
| Physical Features | ||||||||
| Dimension(W×H×D) | 34×115×100 mm | |||||||
| Power dissipation | 19.2W | |||||||
| Power Supply Features | ||||||||
| Rated input voltage | 24V DC | |||||||
| Input voltage rang | 20.4V~28.8V DC | |||||||
| Input current | 0.8A | |||||||
| Polarity reverse connection protection | Yes | |||||||
| Bus power supply voltage | +5V DC | |||||||
| Bus power supply current | 1.6A | |||||||
| LED Indicator Features | ||||||||
| 24V power indicator (green) | On: 24VDC power supply is normal; Off: No 24VDC power supply | |||||||
| SF indicator(red) | On: system failure; Off: no fault | |||||||
| BF indicator(red) | On: bus failure; Off: no fault | |||||||
| FRCE indicator(yellow) | On: there is a mandatory item; Off: No item is forced (also can be controlled via the scrapers command) | |||||||
| RMC indicator(green) | On: the remote server has been successfully communicated (Ethernet communication port parameters have been configured correctly); Off: failure to communicate with the remote server or disable communication with the remote server (allow and disable communication with the server via the dial switch control) | |||||||
| RUN indicator(green) | On:the system is running; Off: the system stops | |||||||
| STOP indicator(yellow) | On: the system stops; OFF = System running | |||||||
| Link1 indicator(green) | On: connection; Off: no connection | |||||||
| SPEED1 indicator(yellow) | On:100Mbps;Off:10Mbps | |||||||
| Link2 indicator(green) | On: connection; Off: no connection | |||||||
| SPEED2 indicator(yellow) | On:100Mbps;Off:10Mbps | |||||||
| I0.0~I1.1(green) | On: there is a signal input; Off: no signal input | |||||||
| Instruction performance | ||||||||
| Bit instruction execution speed | 0.086µs/step | |||||||
| Floating-point instruction execution speed | 1.4µs/step | |||||||
| Memory | ||||||||
| User program memory | 256KB+64KB(Secret memory) | |||||||
| User data memory | 1MB | |||||||
| Power down retention memory | 32KB | |||||||
| Integrated communication function | ||||||||
| Bus interface | provides extension module interface | |||||||
| USB port | provides 1*USB main device interface | |||||||
| EtherNET port | 1*EtherNET port | |||||||
| RS485 port | 1*RS485 port | |||||||
| EtherCAT port | 1*EtherCAT port | |||||||
| CAN port | 1*CAN port | |||||||
| RS485 port | ||||||||
| Number of communication interfaces and protocols | 1*RS485 port,PPI/MPI,free port protocol (built-in MODBUS_RTU protocol) | |||||||
| Free port baud rate | Baud rate 1.2Kbps~115.2Kbps,built-in Modbus master/slave function | |||||||
| PPI/MPI baud rate | 9.6Kbps,19.2Kbps,187.5Kbps | |||||||
| Maximum cable length per segment | Using isolation repeater: 1000m(187.2Kbps) | |||||||
| 1200m(38.4Kbps) | ||||||||
| No isolation repeater used: 50M | ||||||||
| Maximum number of stations | 32 for each segment and 126 for each network | |||||||
| Point-to-point (PPI master mode) | Yes(NETR/NETW), with a maximum of 8 connections, each connection communicating a maximum of 200 bytes | |||||||
| MPI connection | 1 MPI slave station and up to 8 MPI master stations | |||||||
| Isolation | Communication port isolation | |||||||
| CANopen port | ||||||||
| Communication port | 1*CAN port | |||||||
| Maximum number of slave stations | 1 master station can be followed by a maximum of 32 slave stations | |||||||
| Protocol type | CANopen DS301 standard protocol | |||||||
| Support function | Supports automatic starting of CANopen Manager | |||||||
| Supports optional slave polling | ||||||||
| Support to start slave stations | ||||||||
| Support the NMT | ||||||||
| Support synchronous production | ||||||||
| Support synchronous consumption | ||||||||
| Support heartbeat generation | ||||||||
| Support activation time creation | ||||||||
| Transmission rate(kbit/s) | 1000 | 1000 | 800 | 500 | 250 | 125 | 50 | 20 |
| Maximum length (m) | 25 | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 |
| Isolation | Communication port isolation | |||||||
| EtherNET port | ||||||||
| Communication port | 1*EtherNET port | |||||||
| Baud rate | 10/100Mbps adaptive | |||||||
| Protocol type | Support UDP_PPI protocol, Modbus_TCP /IP master and slave protocol, support Socket free programming, support S7 protocol, support Ethernet programming and Ethernet communication between CPU | |||||||
| Maximum length of each cable | 100m connection directly | |||||||
| Maximum number of connections per site | UDP_PPI supports a maximum of 8 connections | |||||||
| ModBus_TCP supports up to 32 connections, | ||||||||
| Socket supports up to 4 connections | ||||||||
| 2 UDP, and 2 TCP | ||||||||
| User data number | Up to 200 bytes for UDP_PPI transmission | |||||||
| Up to 240 bytes are used for ModBus_TCP transport | ||||||||
| Maximum of 512 bytes are used for Socket transmission | ||||||||
| DHCP function | Support | |||||||
| Remote monitoring/programming support | Support | |||||||
| Isolation | Communication port isolation | |||||||
| EtherCAT port | ||||||||
| Communication port | 1*EtherCAT port | |||||||
| Baud rate | 100Mbps adaptive | |||||||
| Protocol type | EtherCAT communication protocol | |||||||
| Maximum length of each cable | 100m connection directly | |||||||
| Maximum number of connections per site | Each master supports up to 64 EtherCAT slave stations | |||||||
| Support function | Support for distributed clock configuration, redundancy settings | |||||||
| Support startup parameter configuration | ||||||||
| Support for configuring PDO parameters and mappings | ||||||||
| Support for configuring bus cycle cycle, configuring startup check vendor ID and product ID | ||||||||
| Programming software | ||||||||
| Programming software package | Magicworks PLC V2.19 and above version | |||||||
| Programming language | LAD,STL,C language | |||||||
| Program organization unit | ||||||||
| Block types | Maximum number | maximum capacity per block | Maximum memory | |||||
| Organization block OB | total number of OB tissue blocks is up to 1024 | 64KB | 256KB+64KB | |||||
| Function FC | 64KB | |||||||
| Function block FB | 64KB | |||||||
| Data blocks DB | 256 | 64KB | 1M | |||||
| Protection function | ||||||||
| Power supply protection | Power supply provides reverse connection protection function and surge absorption function | |||||||
| Interface protection | Communication port lightning protection | |||||||
| Local I/O expand capabilities | ||||||||
| Maximum number of racks | 4 | |||||||
| Maximum number of modules | Main rack extensions: 11 (power module, CPU, relay module, 8 signal modules) Slave rack:10(power module, relay module, 8 signal modules) | |||||||
| Remote I/O expansion capabilities | ||||||||
| CAN extends the maximum number of master stations | 8 | |||||||
| Maximum number of CAN slave stations | Each master station CAN connect up to 32 CAN slave stations (277C) | |||||||
| Maximum number of EtherCAT extended slave station | Connect up to 64 EtherCAT slave modules, each EtherCAT slave module has a maximum of 8 signal modules | |||||||
| Support motion control function | ||||||||
| Motion control function | Conforms to the single axis motion control function of PLCopen standard (positioning, speed and return to the original, etc.), linear/arc interpolation function, continuous interpolation function, electronic CAM, electronic gear function. | |||||||
| Support high-level language functions | ||||||||
| High-level language | Supports C language programming capabilities | |||||||
| Data area and retention features | ||||||||
| Data area type | Size | Addressing range | Addressing property | Access property | Hold property | |||
| Digital Volume Map(I) | 256bytes | IB0-IB255 | Read/write | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
| Digital volume(Q) | 256bytes | QB0-QB255 | Read/write | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
| Analog volume (AI) | 1024bytes | AIW0-AIW1022 | Read only | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
| Analog volume(AQ) | 1024bytes | AIW0-AIW1022 | Write only | Immediate access/direct access/indirect access | Power down hold data are not supported | |||
| Variable memory(V) | 65536bytes | VB0-VB65535 | Read/write | Direct access/indirect access | Support power down hold data | |||
| Special memory Area (SM) | 2048bytes | SMB0-SMB2047 | SMB0-SMB29 Read Only/SMB30-SMB2047 Read/write | Direct access/indirect access | Power down hold data are not supported | |||
| Bit memory(M) | 32bytes | MB0-MB31 | Read/write | Direct access/indirect access | Support power down hold data | |||
| Local variable(L) | 128bytes | LB0-LB127 | Read/write | Direct access | Startup to stop the same call position subroutine can be keep,power down hold data are not supported | |||
| Accumulator register(AC) | 4 | AC0-AC3 | Read/write | Direct Access | Power down hold data are not supported | |||
| Step register(S) | 32bytes | SB0-SB31 | Read/write | Direct access/indirect access | Power down hold data are not supported | |||
| Timer(T) | 1ms*36 | T0-T2047 | — | Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed | The current count value can be power down hold data, the status bit can not be hold | |||
| 10ms*752 | ||||||||
| 100ms*1260 | ||||||||
| Counter(C) | 2048 | C0-C2047 | — | Timing registers can be directly/indirectly accessed, the status bit can only be directly accessed | The current count value can be power down hold data, the status bit can not be hold | |||
| Data block(DB) | 512KB | — | Read/write | Direct access/indirect access | 16KB power down hold data | |||
| Diagnostic function | ||||||||
| Number of diagnostic event buffer bars | 500, and the oldest one is overwritten when the buffer is full | |||||||
| Number of diagnostic event power down hold | 500 | |||||||
| The event recording accuracy | 1ms | |||||||
| Diagnostic interrupt | Support | |||||||
| Diagnostic LED indication | Support | |||||||
| Real time clock | ||||||||
| Power-down retention time | Power-down retention time is about 112 hours (typical value), and the power-down retention time can reach at least 1 year after H56 is connected with external battery | |||||||
| Accuracy | Less than 60 seconds per month | |||||||
| Interrupt | ||||||||
| Timed interrupt | 4 | |||||||
| Input interrupt | 10 | |||||||
| High speed counter interrupt | 6 | |||||||
| Digital input features | ||||||||
| Integrated IO | 10 | |||||||
| Input type | Leak/source | |||||||
| Rated voltage | 24V DC | |||||||
| Input voltage range | 20.4~28.8V DC | |||||||
| Surge voltage | 35V DC,last for 0.5s | |||||||
| Logic 1 signal (min.) | 15 VDC,2.5mA | |||||||
| Logic 0 signal (Max) | 5 VDC,1mA | |||||||
| Connect 2-wire proximity switch sensor (BERO) | 1mA(maximum allowable leakage current) | |||||||
| Input filtering | Support 0.2us,0.4us,0.8us,1.6us,3.2us,6.4us,12.8us、0.2ms,0.4ms,0.8ms,1.6ms,3.2ms,6.4ms,12.8ms,default is 6.4ms | |||||||
| Isolation (field and logic) | 500V AC,1min | |||||||
| Isolation group | See wiring diagram | |||||||
| Simultaneous connection input | 10 | |||||||
| Maximum cable length | 500m(standard input) | |||||||
| Shielded | 50m(high speed counter input) | |||||||
| Unshielded | 300m(standard input) | |||||||
| Pulse capture input | 10 | |||||||
| High speed counter | Total | 6 | ||||||
| Single phase | 6×500KHz | |||||||
| Two phase | 4×250KHz | |||||||

Power interface definition
4pin terminals spaced at 3.81mm apart | Symbol | Signal definition |
| L+ | +24V power positive |
M | +24V power negative | |
| +24V power Ground | |
-- | -- |
USB interface definition
USB port | No. | Signal | Signal definition |
![]() | 1 | V_BUS | +5V power |
2 | Data- | Data- | |
3 | Data+ | Data+ | |
4 | GND | Ground |
EtherNET/EtherCAT interface definition
RJ45 port | No. | Signal | Signal definition |
| 1 | TX+ | Positive end of data transmission |
2 | TX- | Negative end of data transmission | |
3 | RX+ | Positive end of data transmission | |
4 | TERM | -- | |
5 | TERM | -- | |
6 | RX- | Negative end of data transmission | |
7 | TERM | -- | |
8 | TERM | -- | |
Shell | PE | Shell ground |
RS485/CAN interface definition
RJ45 port | No. | Signal | Signal definition |
| 1 | CAN_H | Positive end of data transmission |
2 | CAN_H | Negative end of data transmission | |
3 | - | -- | |
4 | A0 | RS485 signal A | |
5 | B0 | RS485 signal B | |
6 | - | -- | |
7 | CAN_GND | CAN_GND signal Ground | |
8 | - | -- | |
Shell | PE | Shell ground |
Dial switch definition
Dial switch | Symbol | Dial direction | Signal definition |
| RUN | Up | System operation |
STOP | Down | System halt | |
Swivel 8 times in 3 seconds | Reset the IP configuration (once from run-> STOP and once from stop-> RUN) |