High Frequency Compatible Ultrasonic Impedance Analyzer for Ultrasound Transducers

Hangzhou Lanben Trade Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Transducer
Place of Origin
ZheJiang, HangZhou
Ultrasonic Impedance Analyzer are mainly applicable to all types of ultrasound devices for measuring impedance characteristics, including: piezoelectric ceramics, transducers, ultrasonic cleaning machines, ultrasonic plastic welding machine, water sound, magnetostrictive materials, ultrasonic grinder , ultrasonic spray, ultrasonic scaler, reversing radar, ultrasonic ranging, phacoemulsification, ultrasonic cleaning, ultrasonic motors and so on all use of ultrasound equipment.

High Frequency Compatible Ultrasonic Impedance Analyzer for Ultrasound Transducers



How to To evaluate the performance of the ultrasonic transducer?

To evaluate the performance of ultrasonic vibration system, it is necessary to analyze from two aspects: parameters and admittance curves:

1) Parameters:

The impedance analyzer can be used to evaluate the performance of various devices such as piezoelectric ceramic sheets, piezoelectric transducers, and entire vibration systems (transducers plus horns, molds). Analysis of ultrasonic device equipment with an impedance analyzer, the most important parameters are as follows:

Fs: The mechanical resonant frequency, ie the operating frequency of the vibration system, should be as close to the expected value as possible in the design and must match the power supply operating point.

For a cleaning machine, the higher the resonant frequency consistency of the vibrator, the better.

For plastic welders or ultrasonic machining, if the horn or mold design is unreasonable, the resonant frequency of the vibrator will deviate from the operating point.

R1: Dynamic resistance, the resistance of the series series of piezoelectric vibrators, the smaller the better under the same support conditions. For cleaning or welding vibrators, it is generally between 5 Ω and 20 Ω. If it is too large, the vibrator or vibration system will have problems, such as circuit mismatch or low conversion efficiency, and short life of the vibrator.

Qm: mechanical quality factor, determined by the conductance curve method, Qm=Fs/(F2-F1), the higher the Qm, the better, because the higher the Qm, the higher the vibrator efficiency; but the Qm must match the power supply, the Qm value is too high The power supply does not match.

For cleaning the vibrator, the higher the Qm value, the better. Generally speaking, the Qm of the cleaning vibrator should be between 500 and 1000. If it is too low, the vibrator efficiency is low. If it is too high, the power supply cannot be matched.

For ultrasonic welding or machining, the Qm value of the vibrator itself is generally around 500~1000, and the whole system is 1500~3000. If it is too low, the vibration efficiency is low, but it can't be too high, because the higher the Qm, the more the working bandwidth Narrow, the power supply is difficult to match, that is, the power supply is difficult to work at the resonant frequency point, and the device cannot work.

CT: Free capacitance, the capacitance value of the piezoelectric device at 1 kHz. This value is consistent with the value measured by the digital capacitance meter. This value subtracts the dynamic capacitor C1 to get the true static capacitance C0, C0 = CT-C1. When using, balance C0 with inductance.

In the circuit design of a washing machine or ultrasonic processing machine, properly balancing C0 can increase the power factor of the power supply. There are two methods for using the inductor balance, parallel tuning and series tuning.

 

Fp: anti-resonance frequency, the resonant frequency of the parallel branch of the piezoelectric vibrator. At this frequency, the impedance Zmax of the piezoelectric vibrator is the largest. If the anti-resonant impedance Zmax is low, the vibrator has a problem.

 

2) Graphics

 

The impedance analyzer provides five kinds of coordinate characteristic diagrams, and the logarithmic characteristic diagram has important significance for the detection of piezoelectric devices. The vibration performance of a piezoelectric vibrator or a vibrating system can be directly judged by a logarithmic graph, which is relatively intuitive and practical.

Under normal circumstances, the admittance circle and the conductance curve are as shown in the following figure.


 The admittance circle is a single circle, and the logarithmic graph has only a pair of minimum and maximum values:

Ultrasonic Impedance Analyzer



Under abnormal conditions, the admittance circle and the conductance curve are as shown in the figure below. There are multiple parasitic small circles on the admittance chart. The logarithmic graph has many pairs of minimum and maximum values:

pro_5_02



Service and shipment

  • Warranty one year for transducer.

  • You can contact us for technical inquiry any time.

  • We supply OEM service for oversea customer, also will keep Confidentiality for our customers.

  • We supply customized products service for small quantity also.

  • Shipment by FED-EX /DHL



  Rps-sonic, consisted with a couple of young people who love ultrasonic very much.The founding members of RPS-SONIC have an average degree of Bachelor's degree or above. They have been in the ultrasonic industry for more than 5 years and have rich experience in ultrasound. The company's business philosophy is: Do not blindly promote any product, find the most suitable product for customers. So before each order, we will confirm all the details, including application details, capacity,equipment conditions, equipment specific information.Before year 2012, we only sale ultrasonic welding equipment , during these twenty year develop, we find, more and more people have problem with the core part of ultrasonic welding equipment -generator and transducer, so we decided to start our business of transducer and generator of our own transducer and generator. Many of the end user meet the transducer problem, they don’t know why transducer broken, and changing the expensive transducer one by one. Actually, one branson /dukane /rinco transducer can use 10~30 year, even the cheapest transducer can use about 5 years. So there must be some reasons if your transducer broken in one year. That’s why we want build Rps-sonic, we need to help more end user to know more about ultrasonic systems, to use ultrasonic equipment better, to save cost when meet problem.The same to ultrasonic equipments, Unreasonable operation may shorter the use-life. So we have to make technical inquiry before operate ultrasonic machine. The key point of ultrasonic machine is resonance, only keep every part in resonance can make the system in best work environment. Of course we can make the transducer/generator replace for Branson /dukane/ rinco/ herrman telsonic welding machine, we can also make transducer/generator for any application of your ultrasonic equipment. We supply OEM service for oversea customers, we already have two OEM customer in USA and German.The high power ultrasonic system with different horn(probe) can work in different area, that why you can see different ultrasonic application , such like: ultrasonic welding , ultrasonic sewing , ultrasonic cutting , ultrasonic slicing, ultrasonic homogenizing and ultrasonic coating.The core components of ultrasonic system are always the ultrasonic generator and the Probe. The design of the vibrator probe and the stability of the ultrasonic generator have always been the most important factors in the ultrasonic application process. All the RPS-SONIC ultrasoic system will be tested 24 hours before shipment. and all the horn(probe) will design by ANASYS and resonance simulation, to confirm the perfect design.If you have any problem in ultrasonic area, welcome contact Rps-sonic.
Similar Product Recommend