Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Measuring range: -0.1MPa ~ 0 ~ 10KPa … 70MPa
☆ Fully made of stainless steel
☆ Standard thread pressure-leading measuring method
☆ Constant - current and - voltage source power supplying
☆ Laser resistance adjusting compensation and full scale temperature performance
☆ Using solid-state piezoresistive pressure sensor, with high reliability and high accuracy.
☆ Designed with small dimensions, and many optional structural forms
☆ Measurement of pressure for all kinds of dynamic and static gas and liquid medium
☆ Auto electronic device
☆ Airspace and aerospace
☆ Pneumatic pressure control
☆ Ventilation system
☆ Industrial measurement
Technical Data | |||||
Measuring Range | -0.1MPa ~ 0 ~ 10KPa … 70MPa | ||||
Over pressure | Two times of measuring scale for over pressure | ||||
Power supplying | 1.5mA DC constant current | 10 ~ 24V DC constant voltage | |||
Zero point output | 0 ± 2 mV DC | 0 ± 2 mV DC | |||
Full-range output | 70 ~ 110mV DC | 70 ~ 110mV DC | |||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS | ||
Long-term stability | ± 0.1% FS / year | ||||
Range of operating temperature | -40 ~ +85 ℃ | ||||
Range of compensating temperature | -40 ~ +50 ℃ | ||||
Temperature performance | Zero point temperature coefficient: ± 0.02% FS (Typical) | ||||
Sensitivity temperature coefficient: ± 0.02% FS (Typical) | |||||
Thermal lagging | ± 0.1% FS |
|
|
|
|
Material | Enclosure: S / S 1Cr18Ni9Ti | Membrane: S / S 316L | |||
Cable: PVC | Sealing: Fluorubber Sealing Ring | ||||
Electrical connection | PG7 Cable Wiring | Tie-in DIN 43650 | |||
Response time (10% ~ 90%) | ≤ 1 ms | ||||
Insulating resistance | 100MΩ / 500V DC | ||||
Enclosure protection degree | IP 67 (Cable Type) | IP 65 (Socket Type) | |||
Weight | Approximately 250g | ||||
Vibration | No change under 10gRMS, 20 ~ 2000Hz | ||||
Impact | 100g, 11ms | ||||
Service life | 1 x 108 Pressurized Cycle | ||||
Medium compatibility | The gas or liquid compatible with 316 stainless steel | ||||
High - accuracy Pressure Sensor |
| Guideline of Selection | High - accuracy Pressure Sensor | ||||||||||||
Pressure type | Gauge pressure (G, may not be indicated); Absolute pressure (A) | ||||||||||||||
| Range | (0 ~ X kPa or 0 ~ X MPa) | |||||||||||||
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||||||
|
|
| 1 |
| ± 0.4% FS | ||||||||||
|
|
| 2 |
| ± 0.25% FS | ||||||||||
|
|
| 3 |
| ± 0.1% FS | ||||||||||
|
|
|
|
|
| Code | Power Supply of energization | ||||||||
|
|
|
|
|
| D1 | 10 ~ 24V DC constant voltage | ||||||||
|
|
|
|
|
| D2 | 1.5mA DC constant current | ||||||||
|
|
|
|
|
|
|
| Code | Signal Output | ||||||
|
|
|
|
|
|
|
| V1 | 0 ± 2mV ~ 90 ± 20mV | ||||||
|
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
|
| F3 | 1 / 4 NPT external thread | ||||
|
|
|
|
|
|
|
|
|
| F4 | 1 / 2 - 20 UNF - 2A | ||||
|
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67 , 2M) | ||||
|
|
|
|
|
|
|
|
|
| W3 | Airspace and aerospace Socket type (IP65) | ||||
|
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HM10 ( 0 ~ 200 kPa) — 1 — D1 —V1 — F2 — W1 —E High - accuracy Pressure Sensor |
|
|
| ||||||||||||
Tips of Selection
Correctly adopt sealing means to prevent the product stability from influencing by the installing stress when installation of the flushed membrane on the site.We may provide the produCT5 withstanding a pressure of 70MPa or higher or produCT5 with wide temperature compensation range at the user’s requests.The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.Please contact us in case of the other special requirements and clearly indicate them when placing an order.