Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ High accuracy, good stability |
|
• • • Working Principle• • • The process pressure is transferred to the central measuring membrane of δ chamber through the isolating membrane on both sides or one side. The central membrane is a tensioned elastic element, which may generate corresponding deformation displacement for the pressure difference on the both side applied on it, of which displacement is direct proportion to the pressure difference. The maximum displacement is approximately 0.1mm. This displacement is converted into a differential capacitance formed on the capacitor pole board and the differential capacitance is converted into 2 – wire 4 ~ 20mA signal output through electronic circuit. | |
HM1151 Capacitor -type Differential Pressure Transducer
• • • Functional Indicators• • •
Object: | Liquid, gas, or vapor |
Range of measurement: | 0 ~ 0.125KPa ~ 40MPa |
Signal output: | 4 ~ 20mA |
Power supply of energization | 12 ~ 45V DC (24V DC generally) |
Load characteristic: | Related to the power supply of energization. The load impedance RL has a relationship to the voltage of the power supply: RL ≤50 (VS – 12) Ω |
Indicating gauge: | Pointer type with an indication 0 ~ 99% scale, LCD display (0 ~ 99% linear) and square root indication 0 ~ 10 scale. |
Explosion – proof: | a. Explosion – isolating type d II BT4 |
| b. Intrinsically safe type in II CT6 |
Measuring scale and zero point: | Externally and continuously adjustable |
Positive and negative immigration: | The lower and upper limit of the scale shall not exceed the scale limit after positive and negative immigration. |
| Maximum positive immigration: 500% of the minimum measuring scale |
| Maximum negative immigration: 600% of the minimum measuring scale |
Range of temperature: | The range of operating temperature for the amplifier: -29 ~ +93℃ (: -25 ~ +70℃ for LT type) |
| The measuring element filled with silicon oil: : -40 ~ +104℃ |
| Flange –type transducer filled with high – temperature silicon oil: : +15 ~ +315℃; that filled with general silicon oil: : -40 ~ +150℃ |
Static pressure and overloading pressure: | 4, 10, 25, 32MPa |
Humidity: | Relative humidity (RH) 0 ~ 99% |
Volume intake capacity: | < 0.16cm3 |
Damping (step response): | Continuously adjustable, between 0.2s ~ 1.67s generally when filled with silicon oil. |
Starting time: | 2s, preheating is unnecessary. |
Accuracy: | ± 0.25% FS; ± 0.5% FS |
Dead zone: | None (≤ 0.1%) |
Stability: | Not exceeding the absolute value of the basic tolerance for the maximum scale within six months. |
Influence of temperature: | Under the maximum scale: zero position tolerance is ± 0.1% / 55℃, the total tolerance is ± 0.15% / 55℃. |
| Under the minimum scale: zero position tolerance is ± 0.1% / 55℃, the total tolerance is ± 0.2% / 55℃. |
Influence of vibration: | On the any axial direction, the tolerance is ± 0.05% / g of the upper limit of the measuring range when the frequency of vibration is 200Hz. |
Influence of power supply: | Less than 0.005% / V of the scale output |
Influence of load: | The load has no influence to it if the power supply is stable. |
Influence of installing position: | 0.24KPa zero point tolerance may be generated, as a maximum, but it may be corrective, without influence to the measuring scale. |
| Isolating membrane: 316LSST, Hastelloy alloy C, MONEL, or tantalum. |
| Gas exhaust / liquid discharging valve: 316LSST, Hastelloy alloy C, MONEL |
| Flange and joint: Electroplated carbon steel, 316LSST, Hastelloy alloy C, or MONEL |
| O – ring contacting medium: NBR, fluorubber |
| Oil filled: Silicon oil or inertia oil |
| Enclosure of electronic parts: Low – copper aluminum alloy |
Pressure – leading connecting part: | The connecting screw hole on the pressurized vessel or chamber is 1 / 4 ~ 18NPT, the connecting screw hole on the pressure – leading joint is 1 / 2 ~ 14NPT. |
Connecting hole of the signal wire: | G1 / 2 |
Weight: | Approximately 5.4kg (excluding accessories) |
Standard accessories: | The flanged joints, gas exhaust valves and liquid discharging valves and one book of instruction manual have been provided for all the variants in the factory before delivery. |
|
|