Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Designed with Germany made high–accuracy force–sensitive chip as a central sensing and measuring element, with a accuracy up to 0.1% FS
☆ Designed with sensor temperature automatic compensation and normalized circuit commissioning to enhance temperature stability indicator up to 0.1% FS / ℃.
☆ May measure corrosive and easily crystalline medium under special requirements
☆ Designed with fully enclosed structure, all structural members made of stainless steel, which may be used in the open air for a long time.
☆ May be used for the site with online temperature measuring for a long time and without calibration.
☆ May be used for hazardous site, with intrinsically safe type Ex ia II CT5
☆ Structural diversification, design may be customized at the customer’s special requirements.
Measuring range | -100KPa ~ 0 ~ 5KPa … 100MPa | |
Permissible over pressure | Two times of full–scale pressure (where 1.1 times of full–scale pressure for the 100MPa product. | |
Type of pressure | Gauge pressure or absolute pressure | |
Medium to be measured | The gas or liquid compatible with 316 stainless steel , | |
Overall accuracy | ± 0.1% FS | ± 0.25% FS |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year |
Zero point temperature drifting | Typical: ± 0.01% FS / ℃ | Maximum: ± 0.15% FS / ℃ |
Sensitivity temperature drifting | Typical: ± 0.01% FS / ℃ | Maximum: ± 0.15% FS / ℃ |
Working temperature | -20~85℃ | |
Compensating temperature | -20~60℃ | |
Ambient temperature | -40~85℃ | |
Range of power supplying | 12 ~ 36V DC( generally 24V DC) | |
Signal output | 4~20mA / 1-5V DC / 0~5V DC / 0.5~4.5V DC | |
Load resistance | ≤(U - 12) / 0.02Ω | |
Enclosure Protection degree | Plug type (IP65); cable type (IP67) | |
Safe explosion–proof | Ex ia II CT5 | |
Tolerance of vibration | ≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g) | |
Response time | ≤2ms | |
Thermal lagging | ± 0.1% FS (typical) | |
Insulation resistance | 100MΩ, 500V DC | |
Weight | Approx. 250g | |
HM22 | High - accuracy Pressure Transducer |
| Guideline of Selection | High - accuracy Pressure Transducer | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X KPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN3650) | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM22 ( 0 ~ 10KPa) |
|
| — 3 | — A1 | — F1 | — W2 High - accuracy Pressure Transducer | ||||||||
Tips of Selection