Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Laser adjusting - resistance temperature compensation
☆ Zero position, full scale adjustable
☆ High accuracy, high reliability, and high stability
☆ RF disturbance immunity
☆ Power supply reversing pole and over – voltage protection
☆ Isolating corrosion – proof, intrinsic explosion – proof
☆ Direct process installation, pointer or digital display on site
☆ Designed with standard intellectual 4 ~ 20 mA, HART protocol (optional)
It is widely be used for many industrial fields such as petroleum, chemical, electric power, metallurgical, pharmaceutical, and food etc, which is ideal for updating the conventional pressure gauge and pressure transducer and ideal for pressure measuring and control instrument and meter in industrial automation field.
Measuring range | 0 ~ 100KPa ~ 0 ~ 5KPa…100MPa | |||
Overloading capacity | Two times of full–scale over pressure (where over pressure for 100MPa is designed with 1.1 times of FS pressure) | |||
Type of pressure | Gauge pressure or absolute pressure | |||
Medium to be measured | The gas or liquid compatible with 316 stainless steel , | |||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS | |
Long-term stability | Typical: ± 0.25% FS / year | Maximum: ± 0.2% FS / year | ||
Zero point temperature drifting | Typical: ± 0.25% FS / ℃ | Maximum:12 ~ 36V ± 0.05% FS / ℃ | ||
Sensitivity temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum:12 ~ 36V ± 0.05% FS / ℃ | ||
Operating temperature | -40~+125℃ | |||
Compensating temperature | -20~+80℃ | |||
Range of power supplying | 12 ~ 36V DC ( generally 24V DC) | |||
Signal output | 4~20mA / 1-5V DC / 0~5V DC / 0.5~4.5V | |||
Load resistance | ≤(U - 12) / 0.02Ω | |||
Signal wire jack | φ8 for cable port | |||
Weight | Approx. 500g | |||
Thermal lagging | ± 0.01% FS (typical) | |||
Response time (10% ~ 90%) | ≤2ms | |||
Enclosure protection degree | IP65 | |||
Safe explosion – proof | Ex ia II CT5 | |||
Tolerance of vibration | ≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g) | |||
Insulation resistance | 100MΩ, 500V DC | |||
Resolution | Infinite small (theoretical), 1 / 100000 (general) | |||
HM25 | Industrial - type Pressure Transducer |
| Guideline of Selection | Industrial - type Pressure Transducer | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | ||||||
|
|
|
|
|
|
| S | 4 ~ 20mA, HART protocol (standard intellectual type) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| L1 | Pointer (0 ~ 99%) display | ||||
|
|
|
|
|
|
|
|
| L2 | 3 1 / 2 LCD display | ||||
|
|
|
|
|
|
|
|
| L3 | 3 1 / 2 LED display | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM25 ( 0 ~ 100KPa) |
|
| — 1 | — A1 | — F1 | — L2 Industrial - type Pressure Transducer | ||||||||
Tips of Selection