Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Strong anti – overloading and anti – impact capacity, with over pressure up to several dozens to hundred times of scale
☆ Adoption of imported ceramic capacitor sensor, with strong signal output, high comprehensive accuracy, and good stability
☆Small temperature drifting due to without intermediate liquid for measuring element
☆ Wide range of pressure, from micro pressure 0.5kPa to high pressure 100MPa, with optional combined pressure with positive and negative pressure
☆ Pure ceramic substrate will not result process pollution. It applies to food and medical industrial.
☆ Strong disturbance immunity, water – proof, dust – proof, vibration – proof, explosion – proof, and corrosion – proof.
☆ Intrinsically safe explosion – proof, with explosion – proof Class Ex ia II CT5
Measuring range | -100KPa ~ 0 ~ 5KPA…100MPa | |||
Overloading capacity | 3 ~ 100 times of maximum rated pressure (the smaller scale, the bigger over pressure times | |||
Type of pressure | Gauge pressure, absolute pressure | |||
Medium to be measured | Corrosive liquid, gas, and vapor (the medium compatible with AL2O3 and 1Cr18Ni9N) | |||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS | |
Medium temperature | -40~+125℃ |
| ||
Ambient temperature | -40~+85℃ |
| ||
Compensating temperature | -20~+80℃ |
| ||
Long – term stability | ± 0.1% FS / year | |||
Zero point temperature drifting | ± 0.02% FS / ℃ | |||
Sensitivity temperature drifting | ± 0.02% FS / ℃ | |||
Range of power supplying | 12 ~ 36V DC ( generally 24V DC) | |||
Signal output | 4~20mA / 1-5V DC / 0~5V DC | |||
Load resistance | ≤(U - 12) / 0.02Ω | |||
Material of structure | Membrane: AL2O3 ceramic | Enclosure: Cast aluminum with low copper content | ||
Connecting material: 1Cr18Ni9N | Sealing structure: NBR, PTFE or Fluorubber | |||
Safe explosion – proof | Ex ia II CT5 | |||
Enclosure protection degree | Plug type (IP65); cable type (IP67) | |||
Response time (10% ~ 90%) | ≤1ms | |||
Weight | Approx. 500g | |||
Thermal lagging | ± 0.01% FS (typical) | |||
Tolerance of vibration | ≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g) | |||
HM26 | Ceramic Capacitor Pressure Transducer |
| Guideline of Selection | Ceramic Capacitor Pressure Transducer | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A), combined pressure with positive and negative pressure (F) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output (Standard power supply of energization | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| B1 | Stainless steel structure | ||||
|
|
|
|
|
|
|
|
| B2 | PMP 133 aluminum alloy structure ( E + H) | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM26 G( 0 ~ 10KPa) |
| — 1 | — A1 | — F1 | — B1 -E Ceramic Capacitor Pressure Transducer | |||||||||
Tips of Selection