Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Fully provided with German HELL made high – accuracy sensing elements, with maximum accuracy up to 0.1% FS
☆ Stable and reliable performance, may be continuously operated for a long time, with good long – term stability
☆ May apply to measure corrosive medium under special requirements
☆ Strong overloading immunity☆ Fast response
☆ May be used for hazardous site, with intrinsically safe type Ex ia II CT5
☆ Structural diversification, design may be customized at the customer’s special requirements.
HM27A negative pressure transducer adopts such new high technologies of German HELM as advanced absolute pressure chip, temperature automatic compensation, and normalized circuit commissioning etc. to expand the absolute pressure range to 5KPa, as a minimal, and to greatly enhance the overall accuracy of the product. This variant features advanced technology, superior performance, reliable quality, small dimensions. It features more advantages and high ratio of performance to cost comparing with the same type of domestic absolute pressure product. |
Technical Data
Medium to be measured | The gas or liquid, and compatible with 316 stainless steel | |||
Type of pressure | Negative gauge pressure (G), silicon – type absolute pressure (A), capacitor thin – membrane absolute pressure (CA) | |||
Overloading capacity | Two times for negative gauge pressure, several dozens to several hundred times for micro - scale absolute pressure | |||
Measuring range | Negative gauge pressure: 0 ~ 5KPa…-_50KPa…-100Kpa | |||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.5% FS | |
Long – term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.1% FS / year | ||
Range of operating temperature | -20~+80℃ | |||
Range of Compensating temperature | -10~+80℃ |
| ||
Ambient temperature | -20~+80℃ |
| ||
Zero point temperature drifting | Typical: ± 0.01% FS / ℃ | Typical: ± 0.15% FS / ℃ | ||
Sensitivity temperature drifting | Typical: ± 0.01% FS / ℃ | Typical: ± 0.15% FS / ℃ | ||
Range of power supplying | 12 ~ 36V DC ( generally 24V DC) | |||
Signal output | 4~20mA / 1-5V DC / 0~5V DC | |||
Load resistance | ≤(U - 12) / 0.02Ω | |||
Enclosure protection degree | Plug type (IP65); cable type (IP67) | |||
Safe explosion – proof | Ex ia II CT5 | |||
Tolerance of vibration | ≤ ± 0.01% FS(Axles X, Y, and Z, 200Hz / g) | |||
Resolution | Infinite small (theoretical), 1 / 100000 (general) | |||
Response time (10% ~ 90%) | ≤1ms | |||
HM27 | Vacuum / Absolute Pressure Transducer |
| Guideline of Selection | Vacuum / Absolute Pressure Transducer | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A), capacitor thin – membrane absolute pressure (CA) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.5% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output (Standard power supply of energization | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F3 | Clamped type | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| W3 | Airspace and aerospace plug | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM27 A( 0 ~ 10KPa) |
| — 1 | — A1 | — F1 | — W2 Vacuum / Absolute Pressure Transducer | |||||||||
Tips of Selection