☆ Measuring range: -100KPa ~ 0 ~ 4KPa…100KPa…1MPa…260MPa
☆ Wide range of medium temperature: -60~+200℃
☆ High accuracy☆ Good stability: ≤ 0.1% FS / year
☆ Designed with disturbance immunity
☆ Good corrosive resistance: Titanium – sapphire membrane
☆ Intrinsically safe explosion – proof
☆ Industrial site process pressure testing
☆ Power generation plane, nuclear power generation station, water conservancy, hydropower
☆ Airspace and aerospace field
☆ Marine and shipbuilding industry
☆ Petroleum and chemical industry
☆ Scientific research and laboratory calibration
☆ Food industry
Measuring range | -100KPa ~ 0 ~ 4KPa…100KPa…1MPa…260MPa | |||
Overloading capacity | Two times of scale for 10MPa product, 1.5 times of scale for the others | |||
Type of pressure | Gauge pressure, absolute pressure | |||
Medium to be measured | All kinds of high – and low – temperature liquid and gas suitable for titanium alloy and stainless steel | |||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS | |
Medium temperature | -65~+150℃ | |||
Ambient temperature | -40~+85℃ | |||
Compensating temperature | -40~+120℃ | |||
Long – term stability | ± 0.1% FS / year | |||
Zero point temperature drifting | Typical: ± 0.015% FS / ℃ | Maximum: ± 0.03% FS / ℃ | ||
Sensitivity temperature drifting | Typical: ± 0.015% FS / ℃ | Maximum: ± 0.03% FS / ℃ | ||
Thermal lagging | ± 0.1% FS (typical) |
| ||
Range of power supplying | 12 ~ 36V DC ( generally 24V DC) | |||
Signal output | 4~20mA / 1-5V DC / 0~5V DC / 0.5-4.5V DC | |||
Load resistance | ≤(U - 12) / 0.02Ω | |||
Insulation resistance | 100MΩ, 500V DC | |||
Response time (10% ~ 90%) | ≤2ms | |||
Enclosure protection degree | IP65 or IP67 | |||
Explosion – proof Class | Ex ia II CT5 | |||
Material of structure | Membrane: Titanium / silicon – sapphire | Enclosure: 1Cr18Ni9Ti stainless steel | ||
Weight | Approx. 250g | |||
HM28 | Sapphire Pressure Transducer |
| Guideline of Selection | Sapphire Pressure Transducer | ||||||||||
| Type of pressure | Gauge pressure (G, may not be indicated); absolute pressure (A) | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output (Standard power supply of energization | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM28 A( 0 ~ 1.0MPa) |
| — 2 | — A1 | — F1 | — W1 -P Sapphire Pressure Transducer | |||||||||
Tips of Selection