☆ Baud rate from 1200 to 230400 bps
☆Overall accuracy up to ± 0.05% FS under special condition
☆ Optional many kinds of pressure unit, may be user – defined
☆ Sampling rate form 10 points / second to 1 point / 50 minutes
☆ RS 485 universal serial bus (USB) loop may connected with 63 sensor, as a maximal
☆ Communication with the computer via control software in Chinese as well as USB, RS - 232 / 485 port, with easy operation☆ Provided with micro – processor for digital compensation, control, and communication
☆ USB, RS - 232 / 485 port directly connecting with the computer
☆ 20 – bit effective resolution
☆ Absolute pressure, gauge pressure, and differential pressure
☆ Zero point and FS output setting
☆ Readable temperature value of the medium to be measured
☆ National defense scientific research | ☆ Scientific research and laboratory calibration |
☆ Nuclear power generation and chemical | ☆ Petroleum survey and investigation |
☆ Military | ☆ High – end equipment accessories |
☆ Airspace and aerospace | ☆ Support for engineering projects |
Technical Data | ||||
Measuring range | -100kPa ~ 0 ~ 5KPa … 100MPa | |||
Overloading capacity | Two times of FS pressure (where over pressure for 100MPa is designed with 1.1 times of FS pressure) | |||
Pressure type | Gauge pressure or absolute pressure | |||
Medium to be measured | The gas or liquid compatible with 316 stainless steel | |||
Overall accuracy | ± 0.05% FS | ± 0.075% FS | ± 0.1% FS | ± 0.25% FS |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | ||
Zero point temperature drifting | Typical: ± 0.005% FS | Maximum: ± 0.01% FS / ℃ | ||
Sensitivity temperature drifting | Typical: ± 0.005% FS | Maximum: ± 0.01% FS / ℃ | ||
Range of operating temperature | -40 ~ +85 ℃ | |||
Range of compensating temperature | -10 ~ +60 ℃ | |||
Range of power supplying | 5 ~ 9V DC | |||
Digital output | RS485 / USB / RS232 | |||
Baud rate | 1200 , 2400 , 9600 , 19200 , 28800 , 57600 , 115200 , 230400 | |||
Data format | 1–bit start bit, 8–bit data bit, 1–bit stop bit | |||
Odd and even calibration | None | |||
Sampling rate | 10 points / second – 1 point / 50 minutes | |||
Resolution | 20 bit 10ppm | |||
HM28 | Digital · Intellectual Pressure / Differential Pressure Transducer |
| Guideline of Selection | Digital · Intellectual Pressure / Differential Pressure Transducer | ||||||||||
| Code | Type of pressure | ||||||||||||
| G | Gauge pressure ( may not be indicated) | ||||||||||||
| A | Absolute pressure | ||||||||||||
| D | Differential | ||||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.25% FS | ||||||||
|
|
|
|
| 2 | ± 0.1% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
| 4 | ± 0.075% FS | ||||||||
|
|
|
|
| 3 | ± 0.05% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output Method | ||||||
|
|
|
|
|
|
| S1 | RS 458 | ||||||
|
|
|
|
|
|
| S2 | RS 232 | ||||||
|
|
|
|
|
|
| S3 | USB | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| P | Flushed membrane type | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM29 9( 0 ~ 100KPa) |
| — 4 | — S1 | — F1 | — W1 Digital · Intellectual Pressure / Differential Pressure Transducer | |||||||||
Tips of Selection