Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ High ratio of performance to ratio
☆ From 0 ~ 0.5KPa to 0 ~ 700KPa
☆ Continuously adjustable zero point and full scale☆ Reverse pole protection and current limit protection
☆ Lightning, radio frequency immunity
☆ Compact structure, beautiful appearance, and easy installation
☆ Normalized design and production to ensure stable quality and performance of the product
☆ May be designed or improved as per the customer’s specific requirements
☆ Measurement of air pressure and flow rate in industrial process
☆ HVAC
☆ Hearth pressure or hearth negative pressure
☆ Monitoring in – the – well ventilation
☆ Purification equipment and cleaning engineering
☆ Flue dust control and protection of environment
☆ Drying chamber pressure boosting and furnace ventilation control
☆ Medial instrument and equipment
☆ Air fan measurement and control
Technical Data | |||
Measuring range | Differential pressure / air pressure : 0 ~ 500Pa…700KPa | ||
Negative pressure: 0 ~ -500Pa…-1KPa…-10KPa…-100KPa | |||
Permissible over pressure | Three times of FS pressure | ||
Medium to be measured | Non – corrosive, dust and powder free, and dry fluid | ||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS |
Medium temperature | -20 ~ +85 ℃ | ||
Compensating temperature | -10 ~ +55 ℃ | ||
Ambient temperature | -10 ~ +80 ℃ | ||
Zero point temperature drifting | Typical: ± 0.2% FS | Maximum: ± 0.05% FS / ℃ | |
Sensitivity temperature drifting | Typical: ± 0.2% FS | Maximum: ± 0.05% FS / ℃ | |
Long – term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | |
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||
Signal output | 4 ~ 20mA / 1 ~ 5V DC | ||
Load resistance | ≤ (U-12) / 0.02Ω | ||
Enclosure material | Hard aluminum alloy surface plastic injection or 304 stainless steel | ||
Protection degree | IP 65 or IP 67 | ||
Process Connection | φ8 tip, with M10×1 installing screws | ||
Explosion – proof marking | Ex ia II CT5 (intrinsically safe explosion – proof) | ||
Weight | Approx. 0.35kg | ||
Response time | ≤1 ms | ||
Thermal lagging | ± 0.01% FS (typical) | ||
Vibrating tolerance | ≤ ± 0.01% FS ( Axles X, Y , Z, 200Hz / g ) | ||
Insulation resistance | 100MΩ, 500V DC | ||
Resolution | Infinite small (theoretical) 1 / 100000 (general) | ||
HM30 | Micro Differential Pressure / Air Pressure Transducer |
| Guideline of Selection | Micro Differential Pressure / Air Pressure Transducer | ||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F3 | φ8 tip, with M10×1 installing screws | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| W3 | Aerospace socket type (IP65) | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM30 (0 ~ 500MPa) |
| — 1 | — A1 | — F2 | — W1 Micro Differential Pressure / Air Pressure Transducer | |||||||||
Tips of Selection
The medium to be measured shall be compatible with the material contacting with the product.The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.Please contact us in case of the other special requirements and clearly indicate them when placing an order.