Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆High ratio of performance to cost
☆ Fully made of stainless steel with small dimensions, light weight, and easy installation
☆ Reliable and stable performance
☆ Range of differential pressure: 0 ~ 10KPa … 2MPa
☆ Static high pressure resistant to 20MPa
☆ Industrial process control
☆ Flow measurement
☆ Medical instrument
☆ Air power measurement
☆ Hydraulic and pneumatic equipment
| ||||||||||
Measuring range | 0 ~ 10KPa…2MPa | |||||||||
Full scale range | 10 ~ 50KPa | 50 ~ 100KPa | 0.1 ~ 0.2MPa | 0.2 ~ 0.5MPa | 0.5 ~ 1MPa | 1 ~ 2MPa | ||||
Positive permissible over pressure | 250KPa | 300KPa | 0.4MPa | 1.0MPa | 2MPa | 4MPa | ||||
Negative permissible over pressure | 100KPa | 200KPa | 0.3MPa | 0.5MPa | 0.7MPa | 1MPa | ||||
Maximun static pressure | ≤20Mpa | |||||||||
Overall accuracy | ± 0.1%FS | ± 0.25%FS | ± 0.4%FS | |||||||
Zero point temperature drifting | ± 0.02%FS / ℃ (typical) | ± 0.05%FS / ℃ (maximum) | ||||||||
Sensitivity temperature drifting | ± 0.02%FS / ℃ (typical) | ± 0.05%FS / ℃ (maximum) | ||||||||
Influence of static pressure | ± 0.05%FS / 100KPa | |||||||||
Range of operating temperature | -10℃ ~ 80℃ | |||||||||
Range of compensating temperature | -10℃ ~ 50℃ | |||||||||
Long-term stability | ± 0.3%FS / year (≤200KPa) | ± 0.1%FS / year (≥200KPa) | ||||||||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | |||||||||
Signal output | 2-wire 4~20mA; s-wire 0 / 1-5V DC | |||||||||
Response time | ≤2ms | |||||||||
Insulation resistance | 100MΩ, 500V DC | |||||||||
Influence of vibration | Change ≤1% after vibration of 3gRMS30 ~ 2000Hz | |||||||||
Impact | Change ≤1% after impact of 100g for 10ms | |||||||||
Service life | 1×108 pressurized cycle | |||||||||
Medium | The gas or liquid compatible with material of structure | |||||||||
Explosion – proof marking | Ex ia II CT5 (intrinsically safe explosion – proof | |||||||||
Weight | Approx 0.35KG | |||||||||
Thermal lagging | ± 0.1%FS (typical) | |||||||||
Enclosure protective degree | Plug Type (IP 65) | Cable Type (IP 67) | ||||||||
HM31 | Differential Pressure Transducer |
| Guideline of Selection | Differential Pressure Transducer | ||||||||||
|
| Range | Measuring Range | |||||||||||
|
| 0 ~ X KPa or 0 ~ X MPa | ||||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | ||||||||
|
|
|
|
| 1 | ± 0.4% FS | ||||||||
|
|
|
|
| 2 | ± 0.25% FS | ||||||||
|
|
|
|
| 3 | ± 0.1% FS | ||||||||
|
|
|
|
|
|
| Code | Signal Output (standard power supply of energization) | ||||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC (12 ~ 36V DC) | ||||||
|
|
|
|
|
|
|
|
| Code | Additional functions | ||||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | ||||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | ||||
|
|
|
|
|
|
|
|
| F0 | Special | ||||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | ||||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | ||||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | ||||
|
|
|
|
|
|
|
|
|
|
|
| |||
HM31 (0 ~ 50kPa) |
| — 1 | — A1 | — F2 | — W1 Differential Pressure Transducer | |||||||||
Tips of Selection
It is recommended that three – valve set should be installed between the point to be measured and the transducer to make sure the medium to be measured is slowly and evenly applied on the positive and negative chambers in order to ensure running safety and reliability of the transducer.It is recommended that the pressure ports on both ends should be located above the horizontal line so as to minimize the influence of the installing position to the product when installing.Please pay attention to the static pressure to be measured shall be less than 20MPa and the over pressure applied on the positive and negative chamber shall not exceed the specified value of the product when selecting.The code E, an additional functional code for selection, and intrinsically safe explosion-proof Ex ia II CT5 must be power supplied via safety barrier.Please contact us in case of the other special requirements and clearly indicate them when placing an order.