Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Intrinsically safe and explosion – isolating certification: Ex d II CT5, Ex d II CT6
☆ Measuring range:-100kPa ~ 0 ~ 200KPa … 5KPa… 200MPa
☆ Optional gauge pressure, absolute pressure, differential pressure
☆ Adoption of explosion – proof genuine HELM pressure sensing chip multi – crystalline silicon film chip, with stable and reliable performance and long service life
☆ Reverse pole and over – voltage protection of power supply
☆ Explosion – proof design, with safety and reliability
☆ Strong disturbance immunity, strong vibrant resistance, and excellent long – term stability
HM60 series of anti - explosive pressure transducer features good performance, small dimensions, flexible design. It features very high ratio of performance to cost and long service life comparing with traditional explosion – proof transducer. It may widely be used for such fields as oilfield, mining well, chemical, electric power, boiler, and natural gas etc.HM60 – E type of pressure transducer is of intrinsically safe explosion – proof pressure transducer, with an explosion – proof marking of Ex ia II CT5, of which explosion – proof certificate of conformity number is CNEx07.0988. It features stable and reliable performance supporting with repetitive type of safety energy limiter or safety barrier.HM60 – D type of pressure transducer is explosion – isolating type of pressure transducer, with an explosion – proof marking of Ex d II CT6, of which explosion – proof certificate of conformity number is CNEx08.2405.HM60 – ED type of pressure transducer is explosion – isolating type of pressure transducer, with an explosion – proof marking of Ex d II CT5, Ex d II CT6, without safety barrier when installing and operating, with simple operation, safety, and reliability.
Technical Data | |||
Measuring range | -100kPa ~ 0 ~ 200KPa … 5KPa… 200MPa | ||
Overloading capacity | Two times of FS pressure (where over pressure for 100MPa is designed with 1.1 times of FS pressure | ||
Pressure type | Gauge pressure, absolute pressure, differential pressure | ||
Medium to be measured | The gas or liquid compatible with 316 stainless steel | ||
Overall accuracy | ± 0.1% FS | ± 0.25% FS | ± 0.4% FS |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | |
Zero point temperature drifting | Typical: ± 0.2% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |
Sensitivity temperature drifting | Typical: ± 0.2% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |
Operating temperature | -20 ~ +85 ℃ | ||
Compensating temperature | -20 ~ +60 ℃ | ||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||
Signal output | 4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC | ||
Load resistance | ≤ (U-12) / 0.02Ω | ||
Insulation resistance | ≥ 2000MΩ (100VDC for testing condition) | ||
Resolution | Infinite small (theoretical) 1 / 100000 (general) | ||
Response time | ≤1 ms | ||
Influence of vibration | Within mechanical vibration frequency 20Hz ~ 1000Hz, change of output is less than 0.1% FS | ||
Weight | Approx. 0.5kg | ||
HM60 | Anti - explosive Pressure Transducer |
| Guideline of Selection | ||||||||||
| Code | Type of pressure | |||||||||||
| G | Gauge pressure ( may not be indicated) | |||||||||||
| A | Absolute pressure | |||||||||||
| D | Differential pressure | |||||||||||
|
| Range | Measuring Range | ||||||||||
|
| (0 ~ X MPa) measuring range | |||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||
|
|
|
|
| 1 | ± 0.4% FS | |||||||
|
|
|
|
| 2 | ± 0.25% FS | |||||||
|
|
|
|
| 3 | ± 0.1% FS | |||||||
|
|
|
|
|
|
| Code | Signal Output | |||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | |||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | |||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | |||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | |||||
|
|
|
|
|
|
|
|
| Code | Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | |||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | |||
|
|
|
|
|
|
|
|
| F0 | Special | |||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | |||
|
|
|
|
|
|
|
|
| W2 | Hirschman socket type (IP65, DIN 43650) | |||
|
|
|
|
|
|
|
|
| W3 | Outline drawing (I) | |||
|
|
|
|
|
|
|
|
| W4 | Outline drawing (II) | |||
|
|
|
|
|
|
|
|
| W0 | Special | |||
|
|
|
|
|
|
|
|
| L1 | Pointer scale (0 ~ 99%) display | |||
|
|
|
|
|
|
|
|
| L2 | 3 1 / 2 LCD display | |||
|
|
|
|
|
|
|
|
| L3 | 3 1 / 2 LED display | |||
|
|
|
|
|
|
|
|
| P | Flushed membrane | |||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | |||
|
|
|
|
|
|
|
|
| D | Explosion - isolating type Ex ia II CT6 | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
HM60 |
| — 1 | — A1 | — F1 | — W3 -D Anti - explosive Pressure Transducer | ||||||||
Tips of Selection