☆ Viscous medium pressure measurement
Technical Data |
| HM70 Hygienic Flat - membrane Pressure Transducer | ||
Medium to be measured | The liquid, gas or vapor compatible with 316 stainless steel | |||
Measuring range | -100kPa ~ 0 ~ 20KPa … 35MPa | |||
Overloading capacity | 1.5 times of FS pressure | |||
Pressure type | Gauge pressure or absolute pressure | |||
|
| |||
Overall accuracy | Typical: ± 0.25% FS | Maximum: ± 0.4% FS | ||
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.2% FS / year | ||
Zero point temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.03% FS / ℃ | ||
Sensitivity temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.03% FS / ℃ | ||
Medium temperature | -20 ~ +85 ℃ | |||
Compensating temperature | -10 ~ +50 ℃ | |||
Ambient temperature | -20 ~ +80 ℃ | |||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | |||
Signal output | 4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC / 0.5 ~ 4.5V DC | |||
Load resistance | ≤ (U-12) / 0.02Ω | |||
Enclosure protective degree | Plug type (IP 67); Cable type (IP 65) | |||
Thermal lagging | ± 0.02% (typical) | |||
Process connection | M30 x 1.5 external thread or clamp | |||
Safe explosion – proof | Ex ia II CT5 | |||
Weight | Approx. 0.5kg | |||
Response time | ≤2 ms | |||
Insulation resistance | 100MΩ 500V DC | |||
HM70 | Hygienic Flat - membrane Pressure Transducer |
| Guideline of Selection | ||||||||||
| Type of pressure | Gauge pressure ( G, may not be indicated), Absolute pressure (A) | |||||||||||
|
| Range | Measuring Range | ||||||||||
|
| (0 ~ X KPa or 0 ~ X MPa | |||||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||
|
|
|
|
| 1 | ± 0.4% FS | |||||||
|
|
|
|
| 2 | ± 0.25% FS | |||||||
|
|
|
|
| 3 | ± 0.1% FS | |||||||
|
|
|
|
|
|
| Code | Signal Output | |||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | |||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | |||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | |||||
|
|
|
|
|
|
| V3 | 0.5 ~ 4.5V DC | |||||
|
|
|
|
|
|
|
|
| Code | Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M30 x 1.5 external thread | |||
|
|
|
|
|
|
|
|
| F2 | Clamp type | |||
|
|
|
|
|
|
|
|
| F0 | Special | |||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | |||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | |||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
HM70 (0 ~ 100KPa |
| — 1 | — A1 | — F1 | — W2 Hygienic Flat - membrane Pressure Transducer | ||||||||
Tips of Selection