Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Provided with enclosure fully made of stainless steel, with excellent corrosion resistant performance
☆Wide range of pressure measurement
☆Wide range of temperature measurement, with very small tolerance of temperature
☆ Working stability and strong disturbance immunity
☆ High reliability and with dual – membrane structure
☆ Small dimensions, light weight, and full variants
☆ Reverse - phase pole over – voltage and over – current protection
☆ Wide range of measuring medium
☆ Industrial process control
☆ Chemical
☆ Power generation engineering
☆ Thermal energy engineering
☆ Petroleum survey and investigation
☆ Airspace and aerospace
☆ Scientific research of national defense
Technical Data | HM80 High - temperature Pressure Transducer | ||||
Measuring range | 0 ~ 10KPa … 1MPa … 100MPa | ||||
Overloading capacity | Two times of FS pressure ((where over pressure for 100MPa is designed with 1.1 times of FS pressure) | ||||
Pressure type | Gauge pressure or absolute pressure or sealed reference pressure | ||||
Medium to be measured | The liquid, gas or vapor compatible with 316 stainless steel | ||||
Overall accuracy | ± 0.25% FS | ± 0.5% FS | ± 1% FS | ||
Operating temperature zone | -40℃ ~ +150℃ | -40℃ ~ +200℃ | -55℃ ~ +250℃ | -25℃ ~ +350℃ | |
Compensating temperature zone | -20℃ ~ +130℃ | -20℃ ~ +180℃ | -20℃ ~ +200℃ | 0℃ ~ +250℃ | |
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.02% FS / year | |||
Zero point temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |||
Sensitivity temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||||
Signal output | 4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC | ||||
Load resistance | ≤ (U-12) / 0.02Ω | ||||
Response time | ≤3 ms | ||||
Thermal lagging | ± 0.1% (typical) | ||||
Tolerance of vibration | ≤ ± 0.01% FS ( Axles X, Y , Z, 200Hz / g ) | ||||
Insulation resistance | 100MΩ 500V DC | ||||
Safe explosion – proof | Ex ia II CT5 | ||||
Enclosure protective degree | Plug type (IP 65); Cable type (IP 67) | ||||
HM80 | High - temperature Pressure Transducer |
| Guideline of Selection | ||||||||||
| Type of pressure | Gauge pressure ( G, may not be indicated), Absolute pressure (A) | |||||||||||
|
| Range | Measuring Range | ||||||||||
|
| (0 ~ X KPa or 0 ~ X MPa | |||||||||||
|
|
| Code | Range of operating temperature | |||||||||
|
|
| C1 | — 40℃ ~ + 150℃ | |||||||||
|
|
| C2 | — 40℃ ~ + 200℃ | |||||||||
|
|
| C3 | — 55℃ ~ + 250℃ | |||||||||
|
|
| C4 | — 25℃ ~ + 350℃ | |||||||||
|
|
| C5 | 0℃ ~ + 800℃0( High - temperature, water - cooled) | |||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||
|
|
|
|
| 0 | ± 1.0% FS | |||||||
|
|
|
|
| 1 | ± 0.5% FS | |||||||
|
|
|
|
| 2 | ± 0.25% FS | |||||||
|
|
|
|
|
|
| Code | Signal Output (Standard power supply of energization) | |||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA ( 12 ~ 36V DC) | |||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC ( 12 ~ 36V DC) | |||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC ( 12 ~ 36V DC) | |||||
|
|
|
|
|
|
|
|
| Code | Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | |||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | |||
|
|
|
|
|
|
|
|
| F0 | Special | |||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | |||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | |||
|
|
|
|
|
|
|
|
| P | Flushed membrane | |||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
HM80 ( 0 ~ 10MPa) | — C1 | — 1 | — A1 | — F1 | — W1 High - temperature Pressure Transducer | ||||||||
Tips of Selection