Membership
Help
南京宏沐科技有限公司
南京宏沐科技有限公司
☆ Provided with enclosure fully made of stainless steel, with excellent corrosion resistant performance
☆ Wide pressure measuring range
☆ Intrinsic frequency up to 2MHz
☆ Working stability
☆ Strong disturbance immunity
☆ Genuine imported set with stable performance
☆ Small dimensions, light weight, full variants and high ratio of performance to costs
☆ Wide range of measuring medium
☆military engineering
☆ Chemical explosion test
☆ Petroleum investigation and mining as well as petroleum well test
☆ Mechanics
☆ Civil engineering
☆ Geo – mechanic
☆ Trauma medical
☆ Hydraulic power mechanical test
Technical Data |
| HM90 High - frequency Dynamic Pressure Transducer | |||
Measuring range | -100KPa ~ 0 ~ 1Kpa ...20KPa … 100MPa | ||||
Overloading capacity | Two times of FS pressure ((where over pressure for 100MPa is designed with 1.1 times of FS pressure) | ||||
Pressure type | Gauge pressure or absolute pressure | ||||
Medium to be measured | The gas or liquid compatible with 316 stainless steel | ||||
Overall accuracy | 0.1% FS | 0.25% FS | 0.4% FS | ||
Intrinsic frequency | 150KHz ~ 700KHz | 500KHz ~ 1MHz | 1MHz ~ 2MHz | ||
Band width of transducer | 0 ~ 1KHz ~ 3KHz | 0 ~ 20KHz | 0 ~ 200KHz | ||
Rising time | 0 ~ 0.2mS ~ 75μS | 0 ~ 12μS | 0 ~ 1μS | ||
Long-term stability | Typical: ± 0.1% FS / year | Maximum: ± 0.02% FS / year | |||
Operating temperature | -40℃ ~ 85℃ (generally) | -10℃ ~ 250℃ (Specially) | |||
Zero point temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |||
Sensitivity temperature drifting | Typical: ± 0.02% FS / ℃ | Maximum: ± 0.05% FS / ℃ | |||
Range of power supplying | 12 ~ 36V DC (24V DC generally) | ||||
Signal output | 4 ~ 20mA / 1 ~ 5V DC / 0 ~ 5V DC | ||||
Load resistance | ≤ (U-12) / 0.02Ω | ||||
Enclosure protective degree | Plug type (IP 65); Cable type (IP 67) | ||||
Response time | ≤3 ms | ||||
Tolerance of vibration | ≤ ± 0.01% FS ( Axles X, Y , Z, 200Hz / g ) | ||||
Port and enclosure | Stainless steel 1Cr18Ni9Ti | ||||
O-ring | Fluorubber | ||||
Sensor membrane | Stainless steel 316L or mono – crystalline silicon | ||||
Safe explosion – proof | Ex ia II CT5 | ||||
Insulation resistance | 100MΩ 500V DC | ||||
Resolution | Infinite small (theoretical) 1 / 100000 (general) | ||||
HM90 | High - frequency Dynamic Pres. Transducer |
| Guideline of Selection | ||||||||||
| Type of pressure | Gauge pressure ( G, may not be indicated), Absolute pressure (A) | |||||||||||
|
| Range | Measuring Range | ||||||||||
|
| (0 ~ X KPa or 0 ~ X MPa | |||||||||||
|
|
| Code | Band width of transducer | |||||||||
|
|
| H1 | 0 ~ 1KHz ~ 3KHz | |||||||||
|
|
| H2 | 0 ~ 20KHz | |||||||||
|
|
| H3 | 0 ~ 200KHz | |||||||||
|
|
|
|
| Code | Overall accuracy (linear + repeatability + lagging) | |||||||
|
|
|
|
| 1 | ± 0.4% FS | |||||||
|
|
|
|
| 2 | ± 0.25% FS | |||||||
|
|
|
|
| 3 | ± 0.15% FS | |||||||
|
|
|
|
|
|
| Code | Signal Output | |||||
|
|
|
|
|
|
| A1 | 4 ~ 20mA | |||||
|
|
|
|
|
|
| V1 | 1 ~ 5V DC | |||||
|
|
|
|
|
|
| V2 | 0 ~ 5V DC | |||||
|
|
|
|
|
|
|
|
| Code | Additional functions | |||
|
|
|
|
|
|
|
|
| F1 | M20 x 1.5 external thread | |||
|
|
|
|
|
|
|
|
| F2 | G 1 / 4 external thread | |||
|
|
|
|
|
|
|
|
| F0 | Special | |||
|
|
|
|
|
|
|
|
| W1 | Cable type (IP67, 2m) | |||
|
|
|
|
|
|
|
|
| W2 | Socket type (IP65, DIN 43650) | |||
|
|
|
|
|
|
|
|
| P | Flushed membrane | |||
|
|
|
|
|
|
|
|
| E | Intrinsically safe explosion - proof type Ex ia II CT5 | |||
|
|
|
|
|
|
|
|
| T1 | Free field (specially used for blasting) | |||
|
|
|
|
|
|
|
|
| T2 | High - temperature resistant type: Up to 250 ℃ for balancing operating | |||
|
|
|
|
|
|
|
|
|
|
|
| ||
HM90 ( 0 ~ 500KPa) | — H1 | — 1 | — V2 | — F1 | — W1 -E -T2 High - frequency Dynamic Pres. Transducer | ||||||||
Tips of Selection