| Model | HT4830S80-145 | HT4840S80-145 | HT4850S80-145 | HT4825U80-145 | HT4830U80-145 | HT4835U80-145 |
| Mains mode | ||||||
| Rated input voltage | 220/230Vac | 110/120Vac | ||||
| Input voltage range | (170Vac~280Vac) ±2% | (90Vac~140Vac) ±2% | ||||
| Frequency | 50Hz/ 60Hz (automatic detection) | |||||
| Frequency range | 47±0.3Hz ~ 55±0.3Hz (50Hz); | |||||
| Overload/short circuit protection | Circuit breaker | |||||
| Efficiency | >95% | |||||
| Conversion time | 10ms (typical) | |||||
| (bypass and inverter) | ||||||
| AC backflow protection | Yes | |||||
| Maximum bypass overload current | 40A | |||||
| Inverter mode | ||||||
| Output voltage waveform | Pure sine wave | |||||
| Rated output power (VA) | 3000(2600/2700 | 4000(3480/360 | 5000(4350/4500 | 2500(2000/2180 | 3000(2500/2600 | 3500(2900/3000 |
| Rated output power (W) | 3000(2600/2700 | 4000(3480/360 | 5000(4350/4500 | 2500(2000/2180 | 3000(2500/2600 | 3500(2900/3000 |
| Power factor | 1 | |||||
| Rated output voltage (Vac) | 230Vac(200/208/220/240Vac Settable) | 120Vac(100/105/110Vac Settable) | ||||
| Output voltage error | ±5% | |||||
| Output frequency range (Hz) | 50Hz ± 0.3Hz | |||||
| Efficiency | >92% | >91% | ||||
| Overload protection | (102% | (102% | ||||
| Peak power | 6000VA | 8000VA | 10000VA | 4000VA | 4500VA | 5000VA |
| Loaded motor capacity | 2HP | 3HP | 4HP | 1HP | 2HP | 2HP |
| Output short circuit protection | Circuit breaker | |||||
| Bypass circuit breaker specification | 63A | |||||
| Rated battery input voltage | 48V (minimum starting voltage 44V) | |||||
| Battery voltage range | 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery...LCD screen can be set) | |||||
| Eco mode | Load ≤ 50W | |||||
| AC charging | ||||||
| Battery type | Lead acid or lithium battery | |||||
| Maximum charge current | 0-60A | 0-40A | ||||
| Charge | ± 5Adc | |||||
| Charge voltage range | 40 - 58Vdc | 40 - 60Vdc | ||||
| Short circuit protection | Circuit breaker | |||||
| Circuit breaker specification | (AC IN) 63A/(BAT) 125A | |||||
| Overcharge protection | Alarm and turn off charging in 1 minute. | |||||
| PC charge | ||||||
| Maximum PV open circuit voltage | 145Vdc | |||||
| PV operating voltage range | 60-145Vdc | |||||
| MPPT voltage range | 60-115Vdc | |||||
| Battery voltage range | 40-60Vdc | |||||
| Maximum output power | 4200W | |||||
| PV charge current range (settable) | 0-80A | |||||
| Charge short circuit protection | BAT circuit breaker and fuse | |||||
| Wiring protection | Reverse polarity protection | |||||
| Hybrid charging Max charger current specifications (AC charger+PV charger) | ||||||
| Max charger current(can be set) | 0-140A | 0-120A | ||||
| Certified specification | ||||||
| Specification certification | CE(EN62109) | |||||
| EMC certification level | EN61000, C2 | |||||
| Operating temperature range | -15°C to 55°C | |||||
| Storage temperature range | -25°C ~ 60°C | |||||
| RH range | 5% to 95% (conformal coating protection) | |||||
| Noise | ≤60dB | |||||
| Heat dissipation | Forced air cooling, adjustable air speed | |||||
| Communicat ion interface | USB/RS485 (WiFi/GPRS)/Dry Node Control | |||||
| Dimensions (L*W*D) | 482*425*133mm | |||||
| Weight (kg) | 13.3 | |||||