PSH (D) series Low frequency inductive load Inverter with as follow power:
PSH-(D)3000-12 3000va single phase full bridge inverter with inductive load
PSH-(D)5000-24 5000va single phase full bridge inverter with inductive load
PSH-(D)6000-48 3000va single phase full bridge inverter with inductive load
PSH-(D)8000-48 3000va single phase full bridge inverter with inductive load
The Xtender series Pure sine wave is the best way to run the inductive loads in your RV. Thanks to its pure sine wave form, the magnetic pole switch is gentle and gradually varied, it will cause no damage to the motor rotor, brush and bearings.
For full bridge inverter with inductive load , compared with the half bridge inverter, the full bridge inverter needs higher technology to solve the problems of magnetic bias and magnetic saturation (our inverters have solved them), and the cost is higher
The main functions of our PSH ( D ) series Xtender Inverter as follows:
1,Inverter
The Xtender Inverter is equipped with a high-performance inverter, which supplier a perfect and very precise sine wave. Any unit designed for the 230V/50HZ electrical grid ( or 120V/60HZ ) may connect to it without any problem,Up to the rated power out of your Xtender. The Inverter is protected against overloads and short-circuits.
Thanks to the largely over-dimensioned performance level,loads of up to three times greater than the Xtender’s rated output can be faultylessly supplied for short ( 3 sec. ) periods of use,thus allowing motors to be started up without problem.
2,Automatic load detection ( Load search )
It can save the battery energy better.
3,Transfer relay
The Xtender Inverter can be connected to an alternative power source such as a Generator or public network.
When the transfer relay is activated,the voltage present at the input of the Xtender is available at the output for the customers connected. At the same time the battery charger goes into operation.
4,Detect of AC input Loss ( UPS )
In this mode,perturbation or lack of voltage of less than one millisecond can be detected ,switching the unit in inverter mode immediately. This mode guarantes a zero or maximumof 15ms transfer time.
5,Limiting the AC input current “ Input limit”
6,Battery charger
The Battery charger for the Xtender Inverter is completely automatic and designed to guarantee on optimum charge for the majority of lead-acid or Gel batteries.
There are also many protection with the remote control on /off such as overload, overvoltage, overheating and battery reverse polarity and so on.
The Technical data:
| Model | PSH ( D ) 3000-12 | PSH ( D )5000-24 | PSH ( D )6000-48 | PSH ( D )8000-48 | |
| Characterisation of the operating performance | |||||
| Nominal battery voltage | 12V | 24V | 48V | 48V | |
| Input voltage range | 9.5-17VDC | 19-34VDC | 38-68VDC | 38-68VDC | |
| Continuous power | 2500VA | 4500VA | 5000VA | 7000VA | |
| Power 30 min. | 3000VA | 5000VA | 6000VA | 8000VA | |
| Power 5 sec. | 7.5KVA | 12KVA | 15KVA | 21KVA | |
| Max.efficiency | 93% | 94% | 96% | 96% | |
| Own consumption stand by | 1.4W | 1.8W | 2.2W | 2.4W | |
| Own consumption ON | 14W | 18W | 22W | 30W | |
| Acoustic level without ventilation | 40 dB | ||||
| Acoustic level with ventilation | 45 dB | ||||
| Maximum load | Up to short-circuit | ||||
| Maximum asymmetric load | Up to Pcont. | ||||
| Load detection (stand-by) | 2 to 25 W | ||||
| Cos p | 0.1-1 | ||||
| Output voltage | Pure sine wave 230Vac (±2%)/120Vac(1) | ||||
| Output frequency | 45Hz-60Hz(1)±0.05%(crystal controlled) | ||||
| Harmonic distortion | <2% | ||||
| Overload and short-circuit protection | Automatic disconnection with 3 time restart attempt | ||||
| Overheat protection | Warning before shut-off- with automatic restart | ||||
| Battery charger | |||||
| Charge Characteristic | 6 steps: Bulk-Absorption-Floating-Equalization-reduced fl oating-periodic absorptionNumber of steps, thresholds, end current and times completely adjustable with the RCC-02/-03 | ||||
| Temperature compensation | With BTS-01 or BSP 500/1200 | ||||
| Power Factor Correction(PFC) according | EN 61000-3-2 | ||||
| Maximum charging current | 160A | 100A | 140A | 120A | |
| Input voltage range | 150 to 265Vac/50 to 140Vac(1) | ||||
| Input frequency | 45 to 65Hz | ||||
| Input current max. (transfer relay)/Output current max. | 50Aac/56Aac | 50Aac/80Aac | |||
| Transfer time | <15ms | ||||
| Multifunction contacts | 2 independent contacts(potential free 3 points,18Aac/5Adc) | ||||
| Dimension hxwxl [mm] | 230x300x500 | ||||
| Protection index | IP20 | ||||
| Operating temperature range | -20 to 55°℃ | ||||
| Relative humidity in operation | 95% without condensation | ||||
| Ventilation | Forced from 55°℃ | ||||
| Warranty | 2 years | ||||
| Weight | 34Kg | 40Kg | 42Kg | 46Kg | |