Inline Type Ultrasonic Flow Meter
The Inline Type Ultrasonic Flow Meter is the pipeline type flow meter, the sensor part is mounted on the pipeline.the ultrasonic wave transducer is integrated in the pipeline sensor.the body of the inline type ultrasonic flow transducer can be selected by carbon steel and stainless steel. The connection can be flange and thread.the stable and the accuracy of the inline type ultrasonic flow transducer is better comparing the other two types of transducers but it is not easy on the installation as the other kinds of transducers.


| Host | Principle | Transit- time ultrasonic flowmeter | |
| Accuracy | ±1% | ||
| Display | 2X20 character LCD with backlight, support the language of Chinese, English and Italy | ||
| Signal Output | 1 way 4~20mA output, electric resistance 0~ 1K, accuracy 0. 1%(optional) | ||
| 1 way OCT pulse output(Pulse width 6~1000ms, default is 200ms) | |||
| 1 way Relay output | |||
| Signal Input | 3 way 4~20mA input, accuracy 0. 1%, acquisition signal such as temperature, press and liquid level | ||
| Connect the temperature transducer Pt100, can finish the heat/energy measurement | |||
| Data Interface | Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS | ||
| Special Cable | Twisted-pair cable, generally, the length under 50 meters ; Select the RS485, transmission distance can over 1000m | ||
| Pipe Installation Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed | |
| Pipe | DN32~6000mm | ||
| Diameter | |||
| Straight Pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump | ||
| Measuring Medium | Medium | water,sea water ,alcohol,Acid and alkali,waste water,beer,all kinds of oil Single liquid can transmit sound wave. | |
| Temperature | -30~160℃ | ||
| Turbidity | No more than 10000ppm and less bubble | ||
| Flowrate | 0~±7m/s,Forward and backward measurement | ||
| Work environment | Protection grade | Host:IP67;flow sensor:IP68 | |
| temperature | Host:-20~60℃;flow sensor:-30~ 160℃ | ||
| Humidity | Host: 85%RH; Flow sensor:can measure under water, water depth^2m (tansducer sealed glue) | ||
| Power Supply | DC8~36V or AC85~264V | ||
| Power Consumption | 1.5W | ||
| Dimension | 132*150*85mm(host) | ||
Product Feature
The Inline Type Ultrasonic Flow Meter is the pipeline type flow meter, the sensor part is mounted on the pipeline.the ultrasonic wave transducer is integrated in the pipeline sensor.the body of the inline type ultrasonic flow transducer can be selected by carbon steel and stainless steel.
The cumulative number of days may be recorded for the first 64 days and for the first 32 months of the month (2 years), and the number of days of the year shall be increased. The accumulated data can be read through the Modbus protocol.
16 up power outage time Flowmeter records. All the data can be read out through MODBUS protocol.
Timing printing, data output function, automatic display of the next print output time, 22 programmable timing printing content. The timing printing function can realize the automatic timing output or automatic recording of the data.
The pulse width of OCT1 cumulative pulse output can be set between 6 milliseconds and 1 second. The factory default value is 200 milliseconds.