Membership
Help
Wuhan Goldhome Hipot Electrical Co., Ltd.
Wuhan Goldhome Hipot Electrical Co., Ltd.
| I. Overview |
This booster is a dedicated supporting instrument for the volt-ampere characteristic tester (hereinafter referred to as the "volt-ampere host"). The maximum voltage reaches 2500V, and the maximum current is 3A. Used for high inflection point (inflection point voltage greater than 1000V) current transformer or voltage transformer volt-ampere characteristic test and AC withstand voltage test with withstand voltage greater than 1000V.
II.The characteristics of the instrument |
1. Large output capacity: the rated output capacity of the instrument is 5kVA.
2. High boost voltage: the highest boost voltage is 2500V, and the maximum current is 3A.
3. High resolution: voltage resolution is 0.1V, current resolution is 1mA.
3. Simple wiring: each function uses independent terminal, wiring to order, easy to learn and use.
4. Flexible configuration: It can be used in conjunction with the VA host according to requirements, and the VA host can also be used independently.
| III.Technical parameters |
Host power input voltage | AC380V | AC220V |
External booster | 0~2500V、0~3A | 0~2000V、0~3A |
Resolution | 0.1V、1mA | |
Precision | ≤0.5% | |
quality | 25kg | |
volume | 360(L)*340(W)*335(H)mm3 | |
| IV、Instructions |
4.1 Scope of use
This booster can only be used in conjunction with ct pt test set, and has the following two functions:
1. Used for high inflection point (inflection point voltage greater than 1000V) current transformer or voltage transformer volt-ampere characteristics test;
2. Used for AC withstand voltage test with AC withstand voltage greater than 1000V.
Note: It is strictly forbidden to use a booster for other tests.
4.2 Current transformer operation
1). Volt-ampere characteristic booster parameter setting: in the current transformer volt-ampere characteristic test interface. Measurement method selection: booster, the maximum output voltage and maximum output current are set according to the tested product.
2). AC withstand voltage booster parameter setting: in the current transformer AC withstand voltage test interface. Measurement method selection: booster, test voltage is set according to test requirements. Setting principle: When the AC withstand voltage test voltage is greater than 1000V, the measurement method selects a booster. At this time, the default voltage of the instrument is 1500V.
Wiring of AC withstand voltage booster: The wiring method of the booster is shown in Figure 5. The test method is the same as that of the single volt-ampere host.
4.3 Voltage transformer operation
1). Volt-ampere characteristic booster parameter setting: in the voltage transformer's volt-ampere characteristic test interface. Measurement method selection: booster, the maximum output voltage and maximum output current are set according to the tested product.
2). AC withstand voltage booster parameter setting: in the AC withstand voltage test interface of the voltage transformer. Measurement method selection: booster, test voltage is set according to test requirements. Setting principle: When the AC withstand voltage test voltage is greater than 1000V, the measurement method selects a booster. At this time, the default voltage of the instrument is 1500V.
Wiring of AC withstand voltage booster: The wiring method of the booster is shown in Figure 9. The test method is the same as that of the single volt-am