Membership
Help
ACE METER TECHNOLOGY CO.,LIMITED
ACE METER TECHNOLOGY CO.,LIMITED
Kiln Fuel Gas Turbine Flow Meter
The gas flow rate of kiln is affected by furnace temperature. Generally speaking, the flow fluctuation range is small, so the gas turbine flowmeter is very suitable for selection. Gas turbine flowmeter has a long history of development and abundant experimental data,Due to its mature technology, high accuracy, good repeatability and small pressure loss, it was selected as the legal measuring instrument in developed countries and widely used in business measurement occasions.


| Main Application | Natural Gas,LPG,Compressed Air,Nitrogen |
| Nominal Diameter | DN25-DN300 |
| Span | 2.5-6500m³/h |
| Rated Pressure | 1.6MPa~4.0MPa |
| Accuracy Level | ±1.5%R 1.0% Selectable |
| Repeatablility | ±0.1% |
| Range Ration | 1:10, |
| Material | Body/Rotor Support:SS304(SS316L optional) |
| Impeller:Double Phase Steel | |
| Shaft:Stainless Steel | |
| Bearing:Stainless Steel Ball Bearing | |
| Process Connection | Flange/Thread NPT/Wafer |
| Working Condition | Medium Temperature:-20℃~+80℃ |
| (Max Customize to150℃) | |
| Ambient Temperature:-20℃~+60℃ | |
| Rated Humidity:5%~90% | |
| Ambient Pressure:86KPa~106KPa | |
| Power | 24VDC |
| 3V 10AH lithium battery. | |
| Consumption | 24VDC power:<1W |
| Battery:≤1W,lifetime>3yrs | |
| Signal Output | Pulse,4-20mA,Switch Signal. |
| DIgital Communication | RS485,MODBUS,HART,PROFIBUS-DP |
| Signal wire joint | Hausman joint/Inner screw M20*1.5 or customized |
| Explosion Proof Grade | ExdIIBT6/ExiaIICT4 |
| Degree of Protection | IP65 or Higher |
The technical measures to prevent the gas turbine wheel from jamming
Pipeline configuration
1) The installed straight pipe section is in accordance with the manufacturer's requirements, and bypass pipe is recommended for gas turbine flowmeter
2) During the pressure regulating process, the pressure shall be adjusted slowly to protect the flowmeter;
3) When the flow is overloaded, it is recommended to use the flowmeter a restrictor (restriction orifice or restriction nozzle) is installed downstream.
2. filter
In field application, it is recommended to install filter between flowmeter and upstream valve.
3.On / off valve operation
Open / close the valve in strict accordance with the manufacturer's requirements. When opening the valve, slowly open the upstream valve first, and then slowly open the downstream valve after the pressure at both ends of the flowmeter is balanced; when closing the valve, slowly close the downstream valve first, and then slowly close the upstream valve.
4 add lubricating oil
After installation and before putting into use, add enough lubricating oil according to the instructions (oil pump indicator), and shorten the oil filling cycle when the gas quality is dirty.




Kiln Fuel Gas Turbine Flow Meter