Control interface: | analog interface |
| Anode voltage: | 80 KV |
| Tube Current: | 0.6 mA |
| Work period: | 99%, no need to preheat |
| Cooling method: | sealed oil cooling, industrial fan cooling |
| Protection function: | over voltage, over current, over temperature protection |
Radiation safety indicators
Leakage radiation:<0.5µGy/h((5cm away from the shell))
Security: safe for film, chips, and electronic products
Single inspection dosage :< 1.0µGy
Radiation protection: 0.5mmPb double-layer environmental protection lead curtain protection is
adopted for the entrance and exit of the passage, and the main body is protected by 2 ~ 6mm lead
plates to ensure that the peripheral radiation of the equipment meets the national safety standards
Installation data:
| Noise level | < 58dB(A) |
| Weight | 220kg |
| Power wastage | 0.5KW(MAX) |
| System Power | AC220V±10%,60Hz±5Hz |
Height of belt | 650 mm |
Tunnel size | 1500 mm(L) * 770mm(W)* 1100mm(H) |
| Package size | 1570 mm(L) * 840mm(W)* 1270mm(H) |
Product Feature:
Modular
The internal circuit structure of the equipment adopts a modular design idea, and through a
reasonable layout design, the anti-interference ability of the equipment is improved to ensure
stable operation of the equipment and convenient maintenance;
Digitization
The hardware system adopts the latest ASIC all-digital design, IN-depth deep acquisition
technology, and optimizes the circuit design relative to the analog acquisition scheme. It has the
characteristics of high integration, strong anti-interference ability, and clear imaging effects;
Intelligent
The software system integrates practical functions such as RTOS real-time image processing
system, TIP dangerous goods insertion, dangerous goods auxiliary alarm, remote control
management, and quick image backup;
Automation
The system integrates one-key switch machine, infrared energy-saving sensor, emergency alarm
prompt, fault self-check and other functions