Welcome Customer !

Membership

XwbooElectronic ComponentsSensorOther SensorsMD0630T01A Compact AC DC Fault Detection Residual Current Sensor Pin Type RCM for EV Charging Sta...
  • $item.Title
  • $item.Title

MD0630T01A Compact AC DC Fault Detection Residual Current Sensor Pin Type RCM for EV Charging Sta...

Ivy Metering Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Other Sensors
Place of Origin
ShangHai, ShangHai
MD0630T01A Compact AC DC Fault Detection Residual Current Sensor Pin Type RCM for EV Charging Station

Product Overview

During the past months, quite some famous European EV charger manufacturers have contacted us to buy MD series of residual current sensors that are core components for mode 2/mode 3 EV chargers designed as type-B RCD/RCMU. IVY team have supported in most of them going through the process of integrating our residual current detecting technology into their EV chargers successfully. The basic request of these professional European customers is to find alternative suppliers that can deliver high-quality AC/DC fault current sensors (also named residual current sensors, residual current device, residual current monitoring unit or leakage current sensors) to mitigate their supply chain risk. 


MD0630T01A is a high sensititivity AC DC leakage current sensor which has the characteristics of accurate measurement, small size and integration. The leakage sensor can be set separately for AC and DC leakage. An alarm signal is generated when the set current is reached. The leakage sensor has a digital output function, which can directly read the current value of DC and AC. This residual current sensor will detect DC and AC residual currents in 50Hz/60Hz AC installations according to IEC62955. It's primarily intended for use in Electric Vehicle charging stations to disconnect the supply to the Electric Vehicle under a DC residual fault current condition. It will protect against DC (6mA) and AC (30mA) residual currents, and will signal to the Smart EVSE if a fault occurs.


MD0630T01A residual current monitoring device monitors and immediately stops electrical risks that can occur during EV charging. The RCD monitor is cost effective as it has no built-in circuit breaker. When the leakage current is detected, an alarm signal will be sent out automatically. MD series Type B RCM/RCD is an ideal protection device against different leakage currents in applications of PV inverters, medical equipment, industrial automation, UPS devices, EV charging facilities, DC screen, fire distribution cabinet, IOT field etc. It is the technology that brings us closest to protection for all known residual fault currents. In addition, our delivery time is also guaranteed.




image.png


Product Features

1. Complies with the DC and AC protection requirements of IEC62752 or IEC62955

2. Small Size; Integration Design; Vertical(Pin, Pin&Cable Type)/Horizontal(Cable Type) Mounting Optional

3. Integrated self-monitoring and test functions; 3000A surge withstand capability

4. AC DC Leakage Data Readable; Alarm Value Programmable; 3 Way Alarm Outputs; Digital Output

5. URAT Comm, with Modbus Protocol; Standard: EN 61000-6-3:2007+A1, EN IEC 61000-6-1:2019

6. Professional Certification: TUV(IEC62955/IEC62752/IEC61851-1/IEC62196); UL2231-1/UL2231-2; IS17017; CE-EMC 

7. Type B RCD/RCMU for EV Charger Protection; Electrical Safety at Low Cost (Compared to Type B RCCB)

8. Robust Mechanical and Electrical Design for Harsh Environmental Conditions


MD0630T01A Compact AC DC Fault Current Detection Sensor Pin Type RCM for EV Charging Station


Product Parameters

Wide voltage input: 12V±20%

Measuring current range: DC current 2-15mA; AC current 3-100mA (default threshold: DC 6mA, AC 30mA)

Accuracy : at 25℃, DC±0,2mA, AC±0.3mA

Can read current value and set alarm current value

Three outputs: DC alarm, AC alarm, AC/DC alarm

Working environment temperature: -25℃~+80℃

Plastic case, small SIP package


EV Charger Application

MD series residual current sensors (RCD/RCM) is an ideal protection device, for the detection and protection of different leakage currents/residual currents/fault currents. The RCD could quickly output alarm signal when people get an electric shock or leakage current exceeds stipulated value, protecting personal and electrical equipment safety.


MD0630T01A EVSE Solutions Residual Current Monitoring Device Type B RCD Sensor for Car Charger


  IVY METERING is the manufacturer and provider in the field of electricity switching & metering. Our main products include switching series (relay&switch), measuring components(CT&shunt), measuring assembly(RCD&sensor), EV charging components(residual current monitor/EV relay/M-bus current sensor/PCB current transformer/power module/DC meter), metering devices(energy meter&IOT device).With the factory in Zhejiang province and sales center in Shanghai city, our products are recognized by the reputable lab/certificates such as SGS, NMI,KEMA,ANSI and exported to more than 68 countries with quality assurance.Based on innovation, integrity, cooperation, win-win, we aim to build organization with employee well-being, lead world in harmonious metrology. What's more we sincerely hope to focus on energy management and light up better life.