Membership
Help
ACE METER TECHNOLOGY CO.,LIMITED
ACE METER TECHNOLOGY CO.,LIMITED
Mechanical Variable Area Flow Meter
The Durable Quality Mechanical Variable Area Flow Meter works base on the differential pressure principle,the float inside will go up and down to give the area to maintain the differential pressure between the position before and after the float.The float go up and down and drive the indicator to show the flow rate.The durable quality mechanical variable area flow meter is totally mechanical type which is easy to install and maintenance,the flow meter do not need external power supply to work which will not be affected by the factor of power.


| Measure Medium | Water,Oil,Compressed Air,Nitrogen |
| Flow range | Water 2.5 l/h to 200 m3/h |
| Air 0.07 to 4500m3/h (201.013bar) | |
| Flow span | 10:01 |
| Accuracy | Standard accuracy: 1.5% High accuracy: 1.0% |
| Standard accuracy (PTFE-Liner): 2.5% High accuracy (PTFE-Liner): 1.5% | |
| Connections | Flange connection |
| Standard: DIN2501DN15-DN200 ) | |
| Special: DIN2512DN15-DN200 | |
| ANSI1/2-8 | |
| The GB JIS users needs | |
| Threaded fittings DIN11851SC40-SC80[1-1/2-3] | |
| According to demands of users | |
| Steam Jacket Connections | Internal threads 1/2 |
| NPT | |
| Flange connection DN15 PN40 DIN2501 | |
| According to demands of users | |
| Max.Allow. pressure | 250bar |
| Temperature range | Fluid temperature |
| -40 to+200Standard type | |
| -20 to+125PTFE-Liner type | |
| -40 to+400High temperature type | |
| Ambient temperature | |
| -40 to+70 | |
| Materials | SS304,SS304L,SS316,SS316L |
| PTFE-Liner | |
| Hastelloy C | |
| Ti | |
| According to demands of users | |
| Protection class | IP67 |
| Supply power | 12-28V DCtwo-wire systembattery power |
| Ex-Design | ExdIIBT6 |
Precautions for installation of Mechanical Variable Area Flow Meter
In order to make the metal tube rotameter work normally and achieve a certain measurement accuracy, the following points should be paid attention to when installing the flow meter:
1. The metal tube rotameter must be installed vertically on the vibration free pipeline. The fluid flows through the flowmeter from bottom to top, and the perpendicularity is better than 2 °, and the horizontal angle is better than 2 ° when installed horizontally;
2. In order to facilitate the maintenance and replacement of flowmeter and cleaning of measuring pipeline, the metal tube rotameter installed on the process pipeline shall be equipped with bypass pipeline and bypass valve;
3. The metal tube rotameter shall have a straight pipe section of more than 5 times the pipe diameter at the inlet and a straight pipe section of 250mm at the outlet;
4. When it is used for gas measurement, the pipeline pressure shall not be less than 5 times of the pressure loss of the flowmeter, so as to make the float work stably;