Membership
Help
Shanghai Towin Lighting and Electronics Co.,Ltd.
Shanghai Towin Lighting and Electronics Co.,Ltd.
Description
The MPUWDS series UV sterilizer of TOWIN is a split type Medium Pressure UV water disinfection system. It contains the Reactor, cleaning system and an electric box. With MPUV, its effective wavelength range covers 200nm~400nm.With less UV lamps, you can get the same purification effect.
Specifications
Inlet/outlet | 1"~12" |
Water treatment quantity | 1~720T/h |
Power supply | AC380V±10V, 60Hz |
Reactor material | 304/316L stainless steel |
Maximum working pressure of system | 150 psi (10.3 bar) |
Casing cleaning device | Manual / Pneumatic / Electric cleaning type |
Advantages
• Comprehensive range of disinfection.
Ultraviolet disinfection technology has been widely applied for efficiently destroying pathogenic microorganisms, bacteria and virus.
• No secondary pollution.
Since no chemical is added, ultraviolet disinfection system will not cause secondary pollution for water and environment.
• Low operational costs, simple operation and maintenance and economical prices.
• Occupied small space.
Occupied small space and easy assembly enable UV equipment to be installed at the place near water and power source. The ultraviolet equipment starts working after connecting the inlet and outlet of the Ultraviolet equipment and powering up.
Use conditions
Water temperature: 0 ° C ~ 50 ° C;
Ambient temperature: 5 ° C ~ 70 ° C;
Relative humidity: less than 93% (at 25 °C)
Voltage: AC380V±10V, 60Hz
Working pressure: 150 psi (10.3 bar), it is forbidden over loading working pressure
Sterilization of drinking water: 1cm UV transmittance (T254): 95%~99%; when the original water quality is lower than the national drinking water standard (chromaticity higher than 15 degrees, turbidity higher than 5 degrees, iron content is higher than 0.3 mg / liter), it should be used pre-treatment method to meet the conditions of use of the equipment.
Aquaculture water sterilization: fresh water and seawater filtered by sand filtration or other treatment.
Sewage: According to the sterilization requirements, the water quality of the disinfection equipment is 1cm (T254): ≥40%; the other requirements is meeting the secondary standard of the National Integrated Wastewater Discharge Standard GB8978-1996.
If the water quality, needs to be disinfected, cannot meet the above requirements. It should be properly pretreated, such as flocculation, sedimentation, filtration, etc.Methods to remove various impurities in the water.
Application
|
|
|
Aquaculture | Aquaculture | Cooling water |
|
|
|
Bottled water | Micro-algae | Pool water |