Membership
Help
Shanghai Towin Lighting and Electronics Co.,Ltd.
Shanghai Towin Lighting and Electronics Co.,Ltd.
Description
What is MP UV Disinfection System?
MP UV disinfection system uses medium pressure lamps with a polychromatic output from 180-400nm wavelength, specifically enhanced to have broad band germicidal properties.
LP UV Lamp |
MP UV Lamp |
The difference between MP and LP UV Sterilizer
1.Wavelength Features Difference
LP UV Lamp:Bactericidal wavelength unvarying; centralized around 254nm.Microorganisms themselves possess regenerating mechanisms, some that are killed under UV rays may still resuscitate,resulting in a failure for effluent microorganisms to meet standards.
MP UV Lamp:Broad-spectrum sterilization; medium pressure lamp can emit light with a wavelength of 365nm.
Experiments have proved that light with a wavelength of 365nm can drastically suppress photoreactivation, and reach a more complete sterilization. Toshiba’s research on this topic won the “Best Paper Award” at the at the Lux Pacifica, Pacific Basin Lighting Congress.


2.Energy Density Difference
The energy density of medium pressure lamps per unit centimeter is fifty times that of low pressure lamps, guaranteeing a powerful bactericidal effect while tremendously lowering the equipment’s area.
Many customers used low pressure UV devices, which yielded satisfying effects after immediate use, but were perplexed when the bacteria level exceeded standards after a few days. After replacing it with our medium pressure UV device, they were well-satisfied.


Technical Parameter
Model | Inlet/Outlet | Reactor Size | Water Flow | Total Power |
TW-MPUWS210-4 | DN100 | Φ159*915 | 70 | 2KW*1 |
TW-MPUWS220-6 | DN150 | Φ219*915 | 130 | 2KW*2 |
TW-MPUWS230-8 | DN200 | Φ323*915 | 200 | 2KW*3 |
TW-MPUWS240-8 | DN200 | Φ323*915 | 260 | 2KW*4 |
TW-MPUWS310-6 | DN150 | Φ219*915 | 120 | 3kw*1 |
TW-MPUWS320-8 | DN200 | Φ323*915 | 250 | 3kw*2 |
TW-MPUWS330-10 | DN250 | Φ323*915 | 380 | 3kw*3 |
TW-MPUWS340-12 | DN300 | Φ377*915 | 500 | 3kw*4 |
TW-MPUWS610-8 | DN200 | Φ273*915 | 230 | 6kw*1 |
TW-MPUWS620-12 | DN300 | Φ323*915 | 500 | 6kw*2 |
TW-MPUWS630-14 | DN350 | Φ426*915 | 750 | 6kw*3 |
TW-MPUWS640-16 | DN350 | Φ426*915 | 1000 | 6kw*4 |
Specifications
Inlet/outlet | 1"~12" |
Water treatment quantity | 1~720T/h |
Power supply | AC380V±10V, 60Hz |
Reactor material | 304/316L stainless steel |
Maximum working pressure of system | 150 psi (10.3 bar) |
Casing cleaning device | Manual / Pneumatic / Electric cleaning type |
Features / Benefits
• Lamp: Use imported TOSHIBA high-strength medium voltage lamp
• UV Intensity Sensor: Real-time monitoring of UV lamps: including light intensity, lamp life.
• Quartz tube cleaning system: automatic cleaning system quickly
• Automatic Control System: PLC-based operation and control system (optional)
• Reliability: Ballasts with long life and stable performance
• Safety: Equipment has faults and high temperature alarms, it will automatic shutdown in emergency situations
• Easy to install: Power cabinet and reactor are connecting with standard cable
Use conditions
Water temperature: 0 ° C ~ 50 ° C;
Ambient temperature: 5 ° C ~ 70 ° C;
Relative humidity: less than 93% (at 25 °C)
Voltage: AC380V±10V, 60Hz
Working pressure: 150 psi (10.3 bar), it is forbidden over loading working pressure
Sterilization of drinking water: 1cm UV transmittance (T254): 95%~99%; when the original water quality is lower than the national drinking water standard (chromaticity higher than 15 degrees, turbidity higher than 5 degrees, iron content is higher than 0.3 mg / liter), it should be used pre-treatment method to meet the conditions of use of the equipment.
Aquaculture water sterilization: fresh water and seawater filtered by sand filtration or other treatment.
Sewage: According to the sterilization requirements, the water quality of the disinfection equipment is 1cm (T254): ≥40%; the other requirements is meeting the secondary standard of the National Integrated Wastewater Discharge Standard GB8978-1996.
If the water quality, needs to be disinfected, cannot meet the above requirements. It should be properly pretreated, such as flocculation, sedimentation, filtration, etc.Methods to remove various impurities in the water.
Application
Methods to remove various impurities in the water.
Sewage disinfection: municipal sewage, hospital sewage, industrial sewage, oilfield water injection, etc.;
Disinfection of water supply: tap water, surface water (well water, river water, lake water, etc.);
Pure water disinfection: water for food, beverage, electronics, medicine, injection, cosmetics and other industries;
Disinfection of culture water: culture, shellfish purification, poultry, livestock breeding, irrigation water for pollution-free agricultural bases, etc.;
Circulating water disinfection: swimming pool water, landscape water, industrial circulating cooling water, etc.;
Others: water reuse water disinfection, water body algae removal, secondary engineering water disinfection, residential water, villa water, etc.
|
|
|
Aquaculture | Aquaculture | Cooling water |
|
|
|
Bottled water | Micro-algae | Pool water |