Globally approved for use in hazardous environments, metal tube rotameter (variable area flow meter) we offer a range of metal tube rotameters that include corrosion-resistant options for metering aggressive fluids and multiple connection options to make it easier to interface our meter into existing industrial systems. Engineered for long-lasting performance.


| Measure Medium | Water,Oil,Compressed Air,Nitrogen |
| Flow range | Water 2.5 l/h to 200 m3/h |
| Air 0.07 to 4500m3/h (201.013bar) | |
| Flow span | 10:01 |
| Accuracy | Standard accuracy: 1.5% High accuracy: 1.0% |
| Standard accuracy (PTFE-Liner): 2.5% High accuracy (PTFE-Liner): 1.5% | |
| Connections | Flange connection |
| Standard: DIN2501DN15-DN200 ) | |
| Special: DIN2512DN15-DN200 | |
| ANSI1/2-8 | |
| The GB JIS users needs | |
| Threaded fittings DIN11851SC40-SC80[1-1/2-3] | |
| According to demands of users | |
| Steam Jacket Connections | Internal threads 1/2 |
| NPT | |
| Flange connection DN15 PN40 DIN2501 | |
| According to demands of users | |
| Max.Allow. pressure | 250bar |
| Temperature range | Fluid temperature |
| -40 to+200Standard type | |
| -20 to+125PTFE-Liner type | |
| -40 to+400High temperature type | |
| Ambient temperature | |
| -40 to+70 | |
| Materials | SS304,SS304L,SS316,SS316L |
| PTFE-Liner | |
| Hastelloy C | |
| Ti | |
| According to demands of users | |
| Protection class | IP67 |
| Supply power | 12-28V DCtwo-wire systembattery power |
| Ex-Design | ExdIIBT6 |
Treatment of float and pointer failure of Metal Tube Variable Area Flow Meter
Causes and treatment methods of float and pointer fault of Metal Tube Variable Area Flow Meter: fault phenomenon: stuck due to particle foreign matter between float and guide shaft or bending of guide shaft; fault treatment method: disassembly and cleaning, removal of foreign matter or fixed layer, straightening of guide shaft and bending of guide shaft are mostly caused by quick opening and closing of solenoid valve, which causes float of Metal Tube Variable Area Flow Meter to rise sharply and rush Strike caused.
Fault phenomenon: stuck due to swelling or thermal expansion of engineering plastic float and conical pipe lining;
Fault treatment method: change corrosion-resistant material parts. Try not to use plastic for medium with higher temperature, instead use corrosion-resistant metal parts
Fault phenomenon: the connecting rod or pointer of the iron powder or particle indicator part around the magnet of the float assembly with magnetic coupling is stuck;
Fault treatment method: dismantle and remove, and use the bypass pipe to fully clean the pipeline at the initial stage of operation. In front of the Metal Tube Variable Area Flow Meter, the filter is equipped with a moving connecting rod which is manually coupled with a magnet, and there is a stuck part for adjustment. Check whether there is any foreign matter between the rotating shaft and the bearing that hinders the movement, remove or replace the parts