Membership
Help
Hangzhou ToupTek Photonics Co., Ltd.
Hangzhou ToupTek Photonics Co., Ltd.
Mechanical parameters | ||||
Dimensions (mm) | 95×68.5×36 | |||
Weight (g) | 210 | |||
Detector specification | ||||
Detector | Sony ILX554 2048 Linear CCD Array | |||
Wavelength Response Range (nm) | 330-1000 | |||
Active Pixels | 2048 | |||
Pixel size (µm) | 14×56 | |||
Saturation Exposure(lx·s) | 0.004 | |||
Saturation Output Voltage | 1V | |||
A/D Resolution | 16 bit | |||
Dark Signal Voltage(mV) | 3 | |||
Sensitivity Non-uniformity | 5% | |||
Sensitivity (V/lx·s) | 200 | |||
Optical Bench | ||||
Optical System | f/4, asymmetrical crossed Czerny-Turner | |||
Focal length (mm) | 45 (Input); 70 (Output) | |||
Entrance Aperture (µm) | 5, 10, 15, 20, 50 .etc width slits or fiber (customizable) | |||
Grating | Various kinds of scoring grating or holographic grating with different grating constants and flare wavelengths (customizable) | |||
Cylindrical Lens | optional | |||
Optical Filter | Band pass or long pass filters to eliminate secondary spectrum | |||
Fiber and Fiber Connection | NA 0.22, SMA905 (customizable) | |||
Spectroscopic | ||||
Wavelength Range | Depends on optical grating | |||
Optical Resolution (nm) | 0.2-10 FWHM (Depends on grating constant, width of slit and detector model) | |||
SNR | 300:1 (Full signal) | |||
Wavelength Tolerance (nm) | About ±0.2 | |||
Dark noise (RMS counts) | 50 | |||
Integration Time | 2ms-4s | |||
Dynamic Range | 333 | |||
Stray light | <0.05% at 550nm | |||
Electronics | ||||
Power Consumption | 300 mA×5 V DC | |||
Data Transfer Speed | Full spectrum into memory every 2.4 ms at USB 2.0 | |||
Computer | ||||
Operating System | Windows /XP/Vista/7 (32 and 64) | |||
Interface | USB 2.0 (480Mbps), compatible with USB 1.1 | |||
Pre-defined System Components | ||||
Name | Customizable Parts | Remark | ||
Slit | Width (µm) | 10, 20, 50, 100 .etc | ||
Grating | Lines Per Unit (L/mm) | 300, 600, 1200, 1800 | ||
Wavelength Range(nm) | 200-1100 (User defied, about 650 range with 600 lines/mm grating) | |||
Fiber | Core Diameter (µm) | 9, 50, 200, 400, 600 .etc | ||
Wavelength Range(nm) | 200-1100 | |||
Outer Protection Layer | Normal or enhanced jacketing | |||
Interface type | SMA 905 (standard) or FC, ST .etc | |||
Detector | Model | Sony ILX554 | ||
Cylindrical Lens | Optional | Enhance system’s light gathering ability | ||
Optional Components | ||||
Name | Remark | |||
Light Source | Used for wide range spectral measurements or wavelength calibration: for example halogen tungsten, xenon or argon light sources | |||
Integration Sphere | Used to acquire uniform light | |||
Reflection Measurement Accessory | Components used for reflection spectrum measurements: for example standard reflection board or specialized clamp | |||
Transmission Measurement Accessory | Components used for transmission spectrum measurement: for example sample holder and various kinds of cuvettes | |||
Packing List | ||||
Name | Amount | |||
ToupTek Microspectrometer | MSPM00554 | |||
Fiber with SMA 905 Interface | 1 | |||
Mini USB Data Transfer Wire | 1 | |||
CD of Software and SDK | 1 | |||