Membership
Help
ACE METER TECHNOLOGY CO.,LIMITED
ACE METER TECHNOLOGY CO.,LIMITED
Natural Gas Orifice Flowmeter
The application of orifice flowmeter in the measurement of natural gas in oil field has realized the advantages of low price, long service life, simple structure, good adaptability, etc., and can directly determine the relationship between differential pressure signal and flow, omit the calibration link, and further improve the measurement accuracy.


| Nominal diameter | DN15-1800mm |
| Accuracy | ±0.5%R/1.0% |
| Medium | Gas, steam and various kinds of liquid |
| Temperature | ≤540℃ |
| Pressure | 0.6mpa~40mpa |
| Range ratio | 15:1 |
| Connection | Flange |
| Body material | stainless steel |
| Power supply | 24VDC(must be equipped with differential pressure transmitter) |
| Output | 4~20mA;HART |
| Explosion proof | ExiaIICT4 |
| Protection | IP65 or IP68 |
| Environment | Environment:-20~60℃ |
Analysis on the installation of orifice flowmeter
The installation of orifice flowmeter in oilfield engineering needs to be carried out in strict accordance with relevant standards. For straight pipe section, orifice plate, transmitter and relevant accessories, there are different performance requirements during installation. The details can be summarized as follows.
1) From the point of view of straight pipe section, under the support of current technical conditions, the installation of straight pipe section in orifice flow meter needs to be determined by the structural form and diameter ratio of front-end choke. When the above parameters are known, the installation length standard of straight pipe section corresponding to orifice flow meter can be directly found and determined according to the national standard. It is also necessary to pay special attention to: if rectifier is installed in the upstream area of orifice plate, the length of straight pipe section corresponding to the installation of orifice plate flow meter can be appropriately shortened in combination with the actual situation.
At present, most of the upstream orifice plates used in petroleum enterprises are equipped with flow regulators, so combined with practical experience, under the background of installing rectifiers at the inner diameter position (13D) of the upstream orifice valve, it is necessary to ensure that the front straight pipe section meets the value requirements of 30d. According to this installation method, it can meet the installation work of orifice flow meter under the condition of any upstream choke. Corresponding to the front straight pipe section, in the installation of the rear straight pipe section, only the consideration of the diameter ratio parameter needs to be determined comprehensively.
From the perspective of other relevant accessories, first of all, for the gasket, in principle, it is required to strictly control the thickness of the material in combination with the requirements of oil field natural gas metering, and the standard should be less than 0.5mm. At the same time, in the installation of gasket, it is required not to protrude the pipe wall, so as to prevent the measurement of orifice flow meter from great error and influence; secondly, for valves, in the installation of valve components related to flow regulation, it is required to take the minimum length of pipe section after throttling element as the installation standard; finally, for throttling devices, it is required to thoroughly install the pipes in the installation area before installation Cleaning and purging..




Natural Gas Orifice Flowmeter