Welcome Customer !

Membership

XwbooWarehouse LogisticsCard ReaderUHF RFID ReaderNS-T5.net Elevator Access Control Panel
  • $item.Title
  • $item.Title

NS-T5.net Elevator Access Control Panel

NORDSON CO., LTD.

Model
Nature of the Manufacturer
Manufacturer
Product Category
UHF RFID Reader
Place of Origin
GuangDong, ShenZhen

NORDSON CO., LTD.

Contact

Phone

Fax

86-755-86377711
Example 1: Elevator Access Control ManagementWe usually have ten or more floors in one lift, support 4pcs Wiegand RFID reader. The system can distinguish the users privilege, then take them to the right floor.If the user has multi-floor privilege, when swiping the card, he can choose the floor he want to go this time, and he can not push other floor buttons.If the users are the security and administrator, they can go to any floor they want according to the privilege settings. Example 2: Cabinet Access ControlIt can......
  • T-Series Elevator Control Board are one reader for more door controller units, including NS-T5.net Elevator Controller and NS-T16 Expansion Controller Board. NS-T5.net can easily achieve 4pcs RFID reader for more door control with higher security level.As for elevator control,users are only authorized to pass specific floor.By using RFID card, QR Code, biological recognition or password to pass door and floor, so it's very apply to hotel's elevator, which can prevent unauthorized access. NS-T16 Expansion Controller Board must work with NS-T5.net Controller Board, at most with four NS-T16 Expansion Controller Board, control 69 door. Nordson T-series one reader for more door controller unit not only apply to elevator in hotel, office building, apartment but also for many door area like electric storage locker and delivery locker.


    Example 1: Lift Access Control Management
    We usually have ten or more floors in one lift,support 4pcs wiegand RFID reader. The system can distinguish the user's privilege, then take them to the right floor.
    If the user has multi-floor privilege, when swiping the card, he can choose the floor he want to go this time, and he can not push other floor buttons.
    If the users are the security and administrator, they can go to any floor they want according to the privilege settings.
    Example 2: Cabinet Access Control
    It can combine with the Adroitor software to manage this.
    When you swiping card, the appoint cabinet will open.
    The administrator can use PC to open all doors at one time to do some check and manage work.
    The cleaner can open all the door to do cleaning work after office-time.






  • 1.One for more door security control unit, support 4pcs wiegand RFID reader, at most control 69 floor or cabinet locker door.
    2.Support multiple Verification Mode to pass specific floor or open cabinet locker door that is authorized.
    3.ARM processors from the United States, input/output protection, components from well-known IC manufacturers.
    4.Standard TCP/IP communication, multi-level lightning protection and surge protection
    5.User Capacity:20000, Data Record: 70000(Power OFF without loss)
    6.Wiegand Reader Port:4ea (26/34bit Wiegand)or other Biometric equipment.
    7. Powerful Software
    When access controller series work with software, it can achieve more complex security function. Such as, access data search, employee shift, attendance statistics.
    ● Access Control and video device linkage
    ● Attendance
    ● On-line access control
    ● Real-time Remote monitoring
    8.Perfect access control management
    The controller has powerful access control function and can provide perfect management of single door access control.
    Realize multi-card opening, password opening, card and password opening and different opening modes in different time periods.
    ● First Card
    ● Multi-card Open
    ● Anti-passback
    ● Remote Control
    ● Threaten Code
    ● Normal Open Automatically
    9.Apply Software: KeylessSafesmart Software Easy Mode/Expert Mode.


  • ModelNS-T5.netNS-T16
    Type5 Floors Elevator Access Control Panel16 Door Expansion Controller unit
    PCB board sizeL171mm * W141mm * H20mmL198mm * W144mm * H20mm
    Power supply10~15VDC10~15VDC
    Reader Port4ea Wiegand26/34 compatible with Motorola, HID, EM, Mifare one/
    CommunicationTCP/IP/Extension RS485RS485
    Maximum number of connectionsStandard is 5 Door16 Door,Max:4pcs Expansion
    Output Port5 FORM-C Relay Output,1 button,1 Door Sensor/
    User Capacity20,000 cards/
    offline storage70,000 records/
    Operating temperature-10°C-50°C
    Run Humidity10-90% RH, non-condensing
    SoftwareKeylessSafesmart Software Easy Mode/Expert Mode.
    ApplicationExample 1: Lift Access Control Management
    Example 2: Cabinet Access Control



  • NS-T5.net Elevator or Multi Door Access Control Panel Wiring Diagram


    2537.73KB
    2022-04-13
     
     
  Dear customers:Thank you for buying Nordson Access Control products, to protect your legal rights and interests, Nordson Electronic Co.,Limited(hereinafter referred to as: Nordson Electronic)make the following warranty and service commitments:? The product(s) are returned to Company within the warranty period? Provided that on NORDSON’s inspection of returned products that the defect is not aresult of accident, misuse, neglect, alteration, water damage, lightning damage, voltage surge damage or other improper use.1.Shipping: The hardware product must be couriered to and from the NORDSON office and the shipping cost must be pre paid and is not the responsibility of NORDSON.2.For the non-human factors of product quality issues, NORDSON offer three-year warranty services for electromagnetic lock; 3-year warranty for access control panel, electric bolt and electric strike; 1 year warranty for exit button, bracket, and power supply. The customers should take charge of the material and the maintain fees if the product damaged under other conditions.3.Remarks:? NORDSON electronic liability is limited to repair, replacement of defective products or product components.? Freight and maintenance costs are at the user’s cost in the maintenance period.? Maintenance lead time is 7 days after receiving maintenance request.