On-line COD automatic analyzer

Shanghai Nuoyu Testing Technology Co., Ltd.

Model
Nature of the Manufacturer
Other
Product Category
Screw Conveyor
Place of Origin
,
On-line COD automatic analyzer

CODG-3000 on-line COD automatic analyzer can work automatically and continuously according to the on-site settings for a long time, which is widely used in industrial pollution sources, industrial process wastewater, industrial sewage treatment plant wastewater, municipal sewage treatment plant wastewater and other occasions. According to the complexity of field test conditions, the corresponding pretreatment system can be selected to ensure the reliability of the test process and the accuracy of the test results, and fully meet the field requirements of different occasions.

    Chemical oxygen consumption (COD) refers to the mass concentration of oxygen corresponding to oxidant consumed when organic and inorganic reducing substances in water samples are oxidized by strong oxidant under certain conditions. COD is also an important index to reflect the pollution degree of water body by organic and inorganic reducing substances. CODG-3000 online COD automatic analyzer can work automatically and continuously according to the field settings, and is widely used in industrial pollution sources, industrial process wastewater, industrial sewage treatment plant wastewater, municipal sewage treatment plant wastewater and other occasions. According to the complexity of field test conditions, the corresponding pretreatment system can be selected to ensure the reliability of the test process and the accuracy of the test results, and fully meet the field requirements of different occasions.


 Chemical oxygen consumption (COD) refers to the mass concentration of oxygen corresponding to oxidant consumed when organic and inorganic reducing substances in water samples are oxidized by strong oxidant under certain conditions. COD is also an important index to reflect the pollution degree of water body by organic and inorganic reducing substances


7.png










Features of the instrument: The unique design makes this product have lower failure rate, lower maintenance, lower reagent consumption and higher cost performance than similar products. 1-select valve assembly: select reagent sampling sequence, with flexible channels, varied functions, minimum dead volume, easy maintenance and long service life. 2-Micro-metering component: Accurate metering of reagents is realized by visual photoelectric system, which overcomes the quantitative error caused by wear of peristaltic pump tube; At the same time, the accurate quantification of trace reagents was realized, and each dose was only 1 ml, which greatly reduced the amount of reagents used. 3-Sample injection component: peristaltic pump sucks under negative pressure, and there is always an air buffer zone between reagent and pump pipe, which avoids the corrosion of pump pipe; Meanwhile, the reagent mixing is simpler and more flexible. 4-Sealed digestion component: high temperature and high pressure digestion system accelerates the reaction process and overcomes the corrosion of equipment caused by volatilization of corrosive gas in open system. 5-Reagent tube: Imported modified PTFE transparent hose with a diameter greater than 1.5mm is adopted, which reduces the probability of clogging of water samples.


Technical parameters:

Methodological basis

National Standard GB11914-89 "Water Quality-Determination of Chemical Oxygen Consumption-Potassium Dichromate"



1e7cb8b23e2a8c5aa41bccceb919ebf.png

measuring range

0-1500 mg/L

temperature compensation

0~60℃

precision

±10%

resolution ratio

0.01mg/L

repetitiveness

±5%

Measurement period

It can be set in 5 ~ 120 min

Power Supply 

220V±10% 50±1 Hz


Calibration period

Adjustable at any time at any interval from 1 to 99 days

Maintenance cycle

Generally, once a month, each time about 30 minutes

output

RS-232 or 4-20mA or RS485

Enclosure size

Height 1500× width 550× depth 450(mm)

environmental requirement

In the room with adjustable temperature, the recommended temperature is+5 ~ 28℃; Humidity ≤90% (no condensation). For indoor use, air conditioning must be turned on. Suggested size of station building is 15m²

other

Abnormal alarm and power failure will not lose data



Shanghai Nuoyu Testing Technology Co., Ltd. specializes in the whole supply chain of R&D, design, production, sales and service of analytical instruments. It is committed to providing reliable analytical instruments for environmental quality monitoring, pollution source monitoring, municipal environmental protection, industrial field control and other fields. Products and reliable test data.Nuoyu gathers user needs, builds a full range of product lines, overall solutions, localized technical services and systematic application training, covering all fields of analysis. It has a core technology system with completely independent property rights, a leading R&D concept, a scientific manufacturing process and an international supply chain network.Based on its own innovation power, integrating industry ecological capabilities, absorbing domestic and foreign technologies, forming a unique product performance, service content and data quality superimposed advantage, carrying forward the professionalism, guiding users to create new application scenarios, leading instrumentation intelligence and green Future trends will bring more incremental value to the market and serve a sustainable world.