Membership
Help
Wenzhou Xihe Electric Co.,LTD.
Wenzhou Xihe Electric Co.,LTD.
The Xtender XTH is a true energy manager, unique and compact, that has 5 main functions. It can be an off-grid inverter, battery charger, current injector, transfer system and provide support to an AC source. With these functions, the available energy can be managed and used in an intelligent and efficient manner.
• Pure sine wave output;
• Outstanding efficiency and overload,low loss
• 5 LEDs show operating states
• Parallel and three-phase setting, up to 9 units (72kVA).
• Ultra-short transfer time (from 0 to 15ms max.).
• Adapt any tough electricity situation;
• Combine industrial and home usage,convenient installation.
• System compatible devices
1.Remote control and display Fangpusun RCC-02
2.Remote control and display Fangpusun RCC-03
3.Fangpusun X-Connect system
4.Battery temperature sensor Fangpusun BTS-01
5.Integrated cooling unit ECF-01
6.Communications cable
7.Fangpusun BSP-500/1200
Model | XTH 3000-12 | XTH 5000-24 | XTH 6000-48 | XTH 8000-48 |
Characterisation of the operating performance | ||||
Nominal battery voltage | 12V | 24V | 48V | 48V |
Input voltage range | 9.5-17VDC | 19-34VDC | 38-68VDC | 38-68VDC |
Continuous Power | 2500VA | 4500VA | 5000VA | 7000VA |
Power 30 min. | 3000VA | 5000VA | 6000VA | 8000VA |
Power 5 Sec. | 7.5KVA | 12KVA | 15KVA | 21KVA |
Max.efficiency | 93% | 94% | 96% | 96% |
Own consumption stand by | 1.4W | 1.8W | 2.2W | 2.4W |
Own consumption stand by | 14W | 18W | 22W | 30W |
Acoustic level without ventilation | 40 dB | |||
Acoustic level with ventilation | 45 dB | |||
Maximum load | Up to short-circuit | |||
Maximum asymmetric load | Up to Pcont. | |||
Load detection (stand-by) | 2 to 25 W | |||
Cos φ | 0.1-1 | |||
Output voltage | Pure sine wave 230Vac (±2%) / 120Vac (1) | |||
Output frequency | 45Hz-60Hz(1) ± 0.05% (crystal controlled) | |||
Harmonic distortion | <2% | |||
Overload and short-circuit protection | Automatic disconnection with 3 time restart attempt | |||
Overheat protection | Warning before shut-off - with automatic restart | |||
Battery charger | ||||
Charge Characteristic | 6 steps : Bulk-Absorption-Floating-Equalization-reduced floating-periodic absorption Number of steps,thresholds,end current and times completely adjustable with the RCC-02/03 | |||
Temperature compensation | With BTS-01 or BSP 500/1200 | |||
Maximum charging current | 160A | 140A | 100A | 120A |
Input voltage range | 150 to 265Vac / 50 to 140Vac (1) | |||
Input frequency | 45 to 65Hz | |||
Input current max . (transfer relay) / Output current max . | 50Aac / 56Aac | |||
Transfer time | < 15ms | |||
Protection index | IP 20 | |||
Operating temperature range | -20 to 55ºC | |||
Ventilation | Forced from 55ºC | |||
Warranty | 2 Years | |||