The utility model is composed of a sealing shell, a grid groove, a sampling device and a dustpan. The product structure is reasonable, easy to use, with multi-point division performance and strong representativeness, which can greatly improve the efficiency and quality of sample preparation. It is suitable for sampling coal, ore or other heterogeneous granular materials.
The open riffle divider is used for the reduction of coal samples. It is the equipment in the laboratory sample room of coal production and use departments. It has simple structure, convenient maintenance, reliable use, and conforms to national standards. There are two kinds of materials: plated plate and stainless steel. In addition, there are national standard and non-standard. Non-standard is divided into large, medium and small dichotomy. The slot width of the dichotomy is 2.5-3 times the maximum particle size of coal.

Reasonable structure, easy to use, with multi-point segregation performance.
Improve the sample dividing efficiency and quality.
The width of the groove is 2.5-3 times of the maximum particle size of the coal mine sample.
Slopes of grooves and other slopes are not less than 60 degree.
Compliance with environmental protection requirements.

The riffle divider is used to divide the coal sample, and it is not necessary to mix before the separation. When feeding, the dustpan should tilt to one side and swing back and forth along the length direction of the divider to make the coal sample pass through the divider more evenly. The coal sample on one side is selected randomly after the division.
1. The width of the grid slot of the divider should be more than 3 times the nominal large particle size of the coal sample to be reduced, and should be of equal width and parallel;
2. Before use, clean all the grids until there is no blockage;
3. The sample must be fed into the riffle divider in a columnar reciprocating swing, and the amplitude of the swing should not exceed the two ends of the divider; no accumulation of objects on the grid of the divider is allowed;
4. Take any sample from one side after the grading, if it is grading several times, keep the samples on both sides alternately;
5. Divide the sample with higher moisture content, do not enter too much sample, and vibrate the two divider at the same time to prevent the wet sample from blocking the grid.

Model | Groove Quantity | Groove Width(mm) | Granularity(mm) |
YX-RD13 | 16 | 39 | ≤13 |
YX-RD06 | 18 | 18 | ≤6 |
YX-RD03 | 24 | 9 | ≤3 |