Welcome Customer !

Membership

XwbooInstrumentationEnvironmental Test ChamberXenon Lamp Weather Resistance Test Chamber, Xenon Lamp Aging Test ChamberOutdoor PID Tester
  • $item.Title
  • $item.Title

Outdoor PID Tester

Zealwe Technology Co,. Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Xenon Lamp Weather Resistance Test Chamber, Xenon Lamp Aging Test Chamber
Place of Origin
ShangHai, ShangHai
Outdoor PID Tester

Test the PID of solar modules under actual outdoor conditions, and the power supply part meets the PID test requirement specified in the IEC62804 standard.


l The grounding of the module's frame end not only simulates the actual situation, but also prevents the potential danger caused by the high pressure of the frame during the test process.

l For each module, the high voltage wire is connected to the positive or negative electrode of the module. The negative wire is connected to the frame.

l Can set test time, and stop automatically.

l The screen shows the test situation, and record the test data;

l The system records temperature, humidity, irradiance, wind speed, wind direction and etc.

l Multiple currents are displayed at the same time, while alarm parameters are set individually, with single-circuit on/off control.

l Multi-channel voltage settings are programmed separately and the voltage can be set as required.

l Each component is connected to a resistor to allow the module to operate at its maximum operating point. The resistors are placed separately and the resistors are attached to the metal housing floor using heat sinks. This makes the resistor effectively dissipates heat. Resistor housing adopts IP65 grade, which has sufficient insulation effect.

Project

Parameters

Voltage range

-1500V~0V/ 0~+1500V

Source effect

≤0.2%

Time drift

≤0.3%/h

Temperature drift

≤0.5‰/℃

Ripple

≤0.5%

Alarm setting range

1~1000 uA /-1000 uA~1

Testing time

Can be set

Insulation resistance

1000MΩ

Irradiance range

0~2000W/㎡

Irradiance accuracy

±5%

temperature range

-50~200℃

Temperature accuracy

±1℃

Temperature repeatability

±0.5℃

Wind speed range

0~70m/s

Starting wind speed

≤0.25m/s

Wind direction range

0~360°

Wind direction resolution

15°

Humidity range

20~99%RH

Humidity accuracy

±5%RH

  The company's products are mainly used in cell and module aging test, solar power plants site test, solar power plant power generation improvement, etc.. Photovoltaic product aging test products meet international standards such as IEC61215, IEC61730, IEC61701, IEC62804, IEC61853, IEC62979, UL1703; Zealwe has extensive experience in the construction of aging labs for photovoltaic products. We can undertake turnkey projects for aging laboratories, complete laboratory centralized monitoring, and assist clients in getting CNAS certification.The company's PID testing products are at the leading level in the world, occupying 96% of the industry market. testing platform is the leader within the world. PID recovery and prevention equipment is widely used with global solar power stations and could match all of the inverter used in the market. String power optimization (S-MPPT) products can effectively solve the voltage mismatch problem of solar power plants and have been widely used in the global market.