Welcome Customer !

Membership

XwbooInstrumentationEnvironmental Test ChamberXenon Lamp Weather Resistance Test Chamber, Xenon Lamp Aging Test ChamberOutdoor Power Generation Comparison System
  • $item.Title
  • $item.Title

Outdoor Power Generation Comparison System

Zealwe Technology Co,. Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Xenon Lamp Weather Resistance Test Chamber, Xenon Lamp Aging Test Chamber
Place of Origin
ShangHai, ShangHai
Outdoor Power Generation Comparison System

The MPPT DC electronic load is connected at ends of the module to precisely compare the DC power generated by the module.


l Modular design, with flexible configuration

l Avoid interference from power grid factors and have high accuracy

l Access solar modules to track the maximum power point (MPPT)

l Low start-up voltage allows accurate tracking of MPPT in the full power range

l Control the on and off states of the system by time or voltage

l Record parameters such as voltage, current, power, and power generation of the modules .

l It can count minute electricity, hour electricity, daily electricity generation, monthly electricity generation, and annual electricity generation for easy inquiry.

l According to the power generation situation, and automatic sorting, then more intuitively to see the power generation capacity of various modules .

l Record parameters such as atmospheric temperature, atmospheric humidity, irradiance, and irradiation, and query in minutes, days, months, weeks, and years.

l Data can be exported and equipped with communication protocols for remote monitoring.

Project

Parameters

Irradiance range

0~2000W/㎡

Irradiance accuracy

±5%

temperature range

-50~200℃

Temperature accuracy

±1℃

Temperature repeatability

±0.5℃

Wind speed range

0~70m/s

Starting wind speed

≤0.25m/s

Wind direction range

0~360°

Wind direction resolution

15°

Acquisition card acquisition frequency

1 second/time to 1000 seconds/time

Electronic load power

0~400W

Electronic load current

0~30A

Electronic load current accuracy

0.1%FS

Voltage range

120V

Voltage accuracy

0.25%FS

Starting voltage

1V

MPPT tracking accuracy

≥99.6%


  The company's products are mainly used in cell and module aging test, solar power plants site test, solar power plant power generation improvement, etc.. Photovoltaic product aging test products meet international standards such as IEC61215, IEC61730, IEC61701, IEC62804, IEC61853, IEC62979, UL1703; Zealwe has extensive experience in the construction of aging labs for photovoltaic products. We can undertake turnkey projects for aging laboratories, complete laboratory centralized monitoring, and assist clients in getting CNAS certification.The company's PID testing products are at the leading level in the world, occupying 96% of the industry market. testing platform is the leader within the world. PID recovery and prevention equipment is widely used with global solar power stations and could match all of the inverter used in the market. String power optimization (S-MPPT) products can effectively solve the voltage mismatch problem of solar power plants and have been widely used in the global market.