Welcome Customer !

Membership

XwbooInstrumentationEnvironmental Test ChamberXenon Lamp Weather Resistance Test Chamber, Xenon Lamp Aging Test ChamberOutdoor test system
  • $item.Title
  • $item.Title

Outdoor test system

Zealwe Technology Co,. Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Xenon Lamp Weather Resistance Test Chamber, Xenon Lamp Aging Test Chamber
Place of Origin
ShangHai, ShangHai
Outdoor test system

Meet the Stability test requirements specified in 4.19(MQT19) clauses of IEC 61215:2016 standards. The system is designed for 10 pcs modules. Meet the Outdoor exposure test requirements specified in 4.8(MQT08) clauses of IEC 61215:2016 standards. The system is designed for 46 pcs modules. Meet the NMOT test requirements specified in 4.5(MQT05) clauses of IEC 61215:2016 standards & NOCT item in IEC61215:2005 standard. The system is designed for 10 pcs+4pcs modules. Meet the Measurement of temperature coefficients specified in 4.4(MQT4) clauses of IEC 61215:2016 standards. Meet the Measurement of Hot-spot endurance test specified in 4.9(MQT9) clauses of IEC 61215:2016 standards and 39 clause of UL1703 standards. Meet the Temperature test specified in 19 clause of UL1703 standards. The system is designed for 10 pcs modules. The below sketch is reference for Stabilization, Outdoor exposure, NMOT/NOCT).

l Monitoring environmental parameters such as irradiance, ambient temperature, wind speed, wind direction, rain.

l Monitoring the module datasheet, such as, module temperature, current, voltage, power.

l One SI cell are settled to inspect the irradiation of the module plane.

l Data logger & display are installed in the cabinet near the panel string. Parameter could be checked at local place.

l Position of environmental sensors are installed as per IEC61730 standard.

l The spare parts or specially designed kit could be used for fixing at least below module:

a. 60 cell module with 1m(w)x 1.6m(H/L)

b. 72 cell module with 1m(W) x 2m (H)

c. First solar series 6 1.23m(W) x 2.1m(H) x 0.05m(thick)

l Modules temperature are detected by 4 wire PT100. One module is connect with 4pcs PT100.

l Optimizer & string inverter are used to Track the max power point (MPPT) of the test module.

l The parameter of data logger could be read by the IPC.

l All the data could be memorized in the hard disc of IPC as CSV or EXCEL format.



Spare parts

Quantity

Description

Parameters

Support rack(for Measurement of temperature co-efficient, outdoor exposure, light soaking, Stability, Hot spot)

1

Inclination

23±5℃

Material

Aluminum or Galvanized steel

Dimension

69000*2200*3000mm(L*W*H)

Support rack for NMOT/NOCT, temperature test)

1

Inclination

30~50°

Material

Aluminum or Galvanized steel

Dimension

19000*3500*3000(L*W*H)

Module temperature sensor

130

Type

4 wire(Class B)

Temperature range

0~250℃

Accuracy

±2℃

Repeatability

±0.5℃

Pyranometer

1

ISO standard

Secondary Standard

Spectral range

285~2800nm

Irradiation range

0~4000W/m2

Irradiance accuracy

±5%

Responsible time

<5S

Standard SI cell with temperature compensation

4

Type

Mono crystalline silicon solar cell

Cell size

50*33mm

Dimension

155*80*40mm

Temperature range

-40~90℃

Type

4 wire

Accuracy

±1℃

Accuracy of irradiation compared with Pyranometer

±5%

Environmental Temperature sensor

1

Temperature range

-40~60℃

Temperature accuracy

±1℃

Temperature repeatability

±0.5℃

Wind speed & wind direction sensor

1

Wind speed range

0~70m/s

Wind speed resolution

0.1m/s

Wind speed accuracy

0.1m/s(<30m/s) or ±3%

Start wind speed

<0.2m/s

Wind direction range

0~360°

Wind direction resolution

1°

Wind direction accuracy

±2°

Rain sensor

1

Range

≤4mm/min

Resolution

0.2mm

Accuracy

±4%

Data logger

1

Acquisition frequency

0.001~1 HZ

Temperature input

RTD(PT100) 4 wire

Signal input

0-10V or 4-20mA

Signal output

0-10V or digital

IV tracker

1

IV tracking accuracy

≥99.5%

Voltage range

≤150V

Voltage accuracy

1%

Current range

≤15A

Current accuracy

1%

Measurement reproducibility

<0.15%

Optimizer(for crystalline module)

66

Rated Input DC Power

500W

Max input voltage

80V

Max input current

13A

MPPT tracking accuracy(EN)

≥98.8%

MPPT voltage range

8 - 80V

Max output Voltage

60V

Max output current

15A

Inverter(for crystalline module)

16

Max voltage

550V

Max current

15A

Rated power

6000W

Output voltage range

180-280VAC

Inverter(for thin film module)

12

Max voltage

450V

Max current

10A

Rated power

1300W

MPPT voltage range

70V-450V

MPPT tracking accuracy(EN)

≥96.5%

Output voltage range

180-280VAC




  The company's products are mainly used in cell and module aging test, solar power plants site test, solar power plant power generation improvement, etc.. Photovoltaic product aging test products meet international standards such as IEC61215, IEC61730, IEC61701, IEC62804, IEC61853, IEC62979, UL1703; Zealwe has extensive experience in the construction of aging labs for photovoltaic products. We can undertake turnkey projects for aging laboratories, complete laboratory centralized monitoring, and assist clients in getting CNAS certification.The company's PID testing products are at the leading level in the world, occupying 96% of the industry market. testing platform is the leader within the world. PID recovery and prevention equipment is widely used with global solar power stations and could match all of the inverter used in the market. String power optimization (S-MPPT) products can effectively solve the voltage mismatch problem of solar power plants and have been widely used in the global market.