KCT20 series pneumatic bump test system
KCT20 series pneumatic bump test system, has replaced the traditional mechanical cam type bump table, is applied to electronic components or devices and other electric and electronic products that are subjected to repetitive shock in use or transportation.
Functions and features:
◆ Full air pressure driving bump, clean and environmentally friendly, good repeatability and high reliability;
◆ The bump frequency can be controlled by adjusting the air pressure, the bump frequency is continuously adjustable, the system is more stable and reliable, the bump frequency is high, and the software operation is convenient;
◆ The test time and bump frequency times can be set arbitrarily, and the test system will automatically stop after the test is completed, which is convenient for users to operate;
◆ The controller has door protection, flywheel protection and zero signal protection, to ensure system safety;
◆ The drop height is adjustable. Use computer control measurement system. When the pulse width is fixed, you only need to input overload value, the drop height will be automatically adjusted by the computer, and the adaptive adjustment of the bump process can be realized, to ensure the repeatability of the bump overload.
Technical parameter:
Model
KCT20-50
KCT20-100
KCT20-200
KCT20-500
KCT20-1000
KCT20-1500
KCT20-2000
Load (kg)
50kg
100kg
200kg
500kg
1000kg
1500kg
2000kg
Table size (mm)
500*
500
600*
600
800*
800
1000*
1000
1200*
1000
1200*
1200
1500*
1500
Shock waveform
Half sine wave
Peak acceleration (m/s2)
30~
1500
30~
1000
30~
1000
30~
1000
30~800
30~600
30~500
Pulse duration (ms)
30~2
30~2
30~3
30~6
30~6
30~6
30~6
Max.
frequency times (times/min)
120
120
100
80
80
60
60
Bump distance automatic adjustment (mm)
150 mm
150 mm
180 mm
180 mm
200 mm
200 mm
200 mm
Overall dimension
(mm)
1000*
1000*
1000
1100*
1100*
1000
1200*
1200*
1100
1300*
1300*
1200
1500*
1500*
1300
1500*
1500*
1300
1500*
1500*
1300
Weight (kg)
1000
1200
1500
2000
2500
3000
3500
Power supply requirements for Table
AC 220V±10%, 50Hz, 2kVA
Power supply requirements for Air compressor
AC 220V±10%, 50Hz, 3kVA or
AC 380V±10%, three-phase, 50Hz, 5kVA
Air source conditions
Air source output pressure is not more than 1.0Mpa.
If there is no air source in the lab, air compressor needs to be
configured;
If there is air source in the lab, and there is a high requirement on
the bump frequency times, it needs to configure a corresponding
air storage tank.
Environment
Temperature: 0~40℃, humidity: ≤90% (25℃), non condense
Notes: Two kinds of configurations are for all models, ground foundation needed and ground foundation free, users can choose according to the requirements.