Welcome Customer !

Membership

XwbooInstrumentationTesting MachineTransformer Testing MachinePower Frequency Series Resonant Test System
  • $item.Title
  • $item.Title

Power Frequency Series Resonant Test System

Wuhan Goldhome Hipot Electrical Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Transformer Testing Machine
Place of Origin
HuBei, WuHan
Main components180kVA/5kV/6.5kV/0.4kV Exciting transformer 1 set300kVA/0.4kV/0.4kV Isolated transformer 1 set180kW/0.38kV Electric Console 1 set600kVA/50kV(8~80H) HV adjustable reactors 1 set600kVA/50kV(10H) Fixed reactors 1set50 kV Voltage divider 1 set Sphere gap 1 set
I.Product overview


The generator AC withstand voltage test requires the use of power frequency withstand voltage, and

the international definition of the power frequency voltage frequency is 45Hz-65Hz; but in many

test occasions, it is required to perform the AC withstand voltage test of 50Hz±1Hz on the

generator[1], and The electric capacity of the generator stator winding to ground is relatively

large. Most domestic test units use resonant transformers to test it. However, the resonant

transformer itself is very heavy and often weighs a ton, making field tests very troublesome.

In response to this, in the Power Frequency Series Resonant Test System, the device adopts an

adjustable reactor to adjust the inductance of the reactor to reach the resonance state, or

adjusts the operating frequency of the system to reach the resonance state, and the above two

methods can also be used to reach the resonance state. When the frequency is required for the

test, adjust the frequency of the excitation source to the required frequency, and then adjust the

inductive reactance of the reactor according to the capacitance of the tested product to make the

system resonate and generate high voltage. During the boost process, how The resonance point is

too high. The resonance point can be accurately found by fine-tuning the frequency to ensure a

high Q value, thereby minimizing the capacitance and the volume and weight of the test equipment.



II、 Main components for 1200kVA/50kV Power Frequency Series Resonant Test System


180kVA/5kV/6.5kV/0.4kV Exciting transformer 1 set

300kVA/0.4kV/0.4kV Isolated transformer 1 set

180kW/0.38kV Electric Console 1 set

600kVA/50kV(8~80H) HV adjustable reactors 1 set

600kVA/50kV(10H) Fixed reactors 1set

50 kV Voltage divider 1 set

Sphere gap 1 set

Schematic diagram about equipment wiring

details


III、Wiring and operation instructions


1.Connect the three-phase four-wire power supply A, C and N with the corresponding terminal on the lower side of the console (if the phase sequence is inconsistent with equipment, the console cannot work and start normally, so phase sequence of the power supply needs to be replaced).

2.Connect console to the voltage regulator, wiring from console to exciting transformer, match the terminal one to one, and specialized aviation plug one to one.

3.Set the overcurrent relay

Protect the overcurrent (LV ammeter meter)

according to the overcurrent protection sign on the panel of console .

Generally converted to LV capacity according to 1/Q capacity of tested equipment , calculate the LV current and voltage under the test voltage, and set the overcurrent protection according to 1.5 times of LV current. Then through simulation test to ensure the overcurrent protection action to cut off the current( 120MW turbine, Q value is about 8 – 10) .If the current of tested object is 8A, voltage is 25Kv, the capacity of device should be 200KV, take Q value as 10, and the LV capacity is 3Kva, LV is 400V, LV current is 250A, and the overcurrent protection setting value is 250A

4.Setting over voltage protection

Electronic overvoltage protection setting: 1.1 times of withstand voltage value, automatically locked voltage boost once over voltage protection act.

5.Connect measurement meter : HV side of tested object connect with voltage divider (HV meter) to measure the HV voltage .

6.Connect with tested object to make AC withstand voltage test

7.Check if all test equipment in good condition before withstand voltage test

8.Security arrangement is complete enough for testing .

9.No-load adjustment test to ensure test device is good condition

10.Boost test: Connect with analog load or tested object, step up/step down button , boost 10% -20%, and then adjust the adjustable reactor .Inductance button When the HV measurement meter indicates maximum value, it means find out resonance point (The voltage reach maxmum value at resonant point),then boost or step-down voltage step by step to test voltage, and the voltage will step-down automaticaly when timing is up .

11.Verify overcurrent protection : Connect with simulated load, monitor and step-up voltage on console, and monitor currrent at the same time , (LV current meter)

When current reach protection setting value , protection will act , trip and cut off power supply.

12.Verify overvoltage protection : Connect with simulated load, monitor and display on console(or monitor from HV mter of voltage divider),

When voltage reach protection setting value, overvoltage protection act, Alarm light is on, cut off the power supply and back to zero automatically .

13.Connect with tested object, adjust the resonance . For resonance in parallel , adjust it until the value on current meter reach minimum .

For resonance in parallel, available to adjust resonance at any time when under 80% test voltage.

Begin to adjust resonance while rated input voltage of exciting transfromer is 10%-20% (LV voltage meter)

Until the the maximun output voltage is the resonane, and not allowed to adjust air gap, to avoid over voltage (Recommend resonance in paralle for test electric generator)

14.Boost to withstand voltage value( due to the voltage increase at Q times, a point - boosting is necessary). If there is no abnormal phenomenon in 1 minute , voltage regulator will step-down to zero automatically .During the test, the relevant personnel should strengthen the monitoring of tested equipment. In case of abnormal phenomenon, or overcurrent protection action, should decrease voltage and cut off the power supply quickly .

15.Switch-off: reduce air gap to zero, close all switches, test complete

16.For same unit, , test in sepearate phase, once the resonance point is adjusted, no need to adjust the air gap when make withstand voltage test for other phase, can directly boost to the test voltage

17.After finish test, can only discconect the wiring after tested object is completely discharged.

18.Tested object

Ac withstand voltage test 18kV/300MW hydrogenerator, the capacitance is 1.6uF when single-phase to ground , and the maximum test voltagenot exceed 39kV.


IV、Reactor configuration for different generator test by using 1200kVA/50kV Power Frequency Series Resonant Test



Relationship List in Test


Reactors

Rated capacity

Rated voltage

Rated current

Capacitance range of tested object( calcuateld data)

Related Inductance

1pc adjustable reactor

600kVA

50kV

12A

0.126~1.26μF

8~80H

1pc adjustable reactor connect wtih 1pc fixed reactor connect in parallel

600kVA+600kVA

50kV

24A

1.15~2.3μF

4.4~8.8H


Product service process

We strictly implement the concept of "customer-centric, integrity in business world" to provide customers with high-quality pre-sales, in-sales and after-sales services!

1. Dear customers, no matter what you need, as long as you contact us, we will do the rest!

2. Our customer service staff will provide you with professional product consultation and technical answers.

3. Understand your demands, establish product service records, and negotiate with you to determine after-sales service methods

4. If necessary, we will arrange professional technical engineers to provide you with video, telephone contact, and on-site debugging services in the way agreed with you!

5. The engineer will explain to you the working principle and test operation steps of the product in detail.

6. The engineer will guide you on-site,video to complete the entire test process, and give professional answers to your technical questions.

7. The engineer will also conduct a comprehensive inspection for the product you purchased, and solve it if there is a fault.

8. After the service is completed, please provide valuable comments or suggestions on our service, and the service information will be synchronized to the after-sales service center.

9. The after-sales service center will actively follow up the service progress and regularly follow up the return visits.


After-sales Service Commitment

1.We guarantee that professional engineers and technicians will answer qustions by telephone, or other channel within 1 hour, deal with equipment failure in time within 24 hours.

2.Upon receipt of the client's request for after-sales service,we promises to provide solutions within 48 hours.

3.We will provide relevant technical training and technical information according to client's requirements.

4.The product can be repaired free of charge for one year and maintained for life.

Notice

1.we are the china manufacturer,your best choice!

2.We have many kinds of product-line,You can visit our web to mix some goods in one order.more selection,more discount.

3.If you have any other products need to buy that won’t show in our website,you can tell us,anything we done not well,please free feel to tell us!

5.We are very appreciated if you can give me a positive feedback when you get the goods,should you have any problem,please don’t forget to contact with us without hesitation.


  Wuhan Goldhome Hi pot Electrical Co.,ltd(short for Goldhome Hi pot) was established in 2008, its predecessor was state-owned third industry enterprises, one of the earliest enterprises specially in develop, design and manufacture high voltage testing equipment in China.In 2016, merged with Wuhan Sang Electric Co., Ltd. , we realize advantageous compartmentalize and resources reorganization.Now it has become a high-tech enterprise integrating R&D, production, marketing installation and commissioning.1.our-historyOur FactoryGoldhome Hi pot is located in Huading Mould Industrial Park, Economic and Technical Development Zone, Wuhan City, Hubei Province, China, working area more than 4000 square meters.As a high-tech enterprise, we are supported by natural advantages from various research universities in Wuhan city. Goldhome Hi pot works closely with professors from State Grid Power Science Research Institute, Electrical Engineering Colleges of Wuhan University and other scientific research institutions, constantly improving technology and updating products . Now Goldhome Hi pot has more than 20 patented technologies, and many software Copyrights!2.our factory-1product and product applicationOur ProductOur advantage products included AC Resonant Test System, PD Free Test System, AC/DC Hi pot Tester, Primary Current Injection, VLF Hi pot Tester, transformer tester,impulse generator,Transformer oil tester,HV Switch gear Tester ,Insulation Tester,ground Resistance Tester,cable fault locator,relay test set,CT PT analyse,arr ester tester and sf6 gas analyzer,etc.Product ApplicationAll the performance indexes of above testing equipment can reach the leading level in China, widely used in power supply bureau, power plant, power construction, railway, petroleum, chemical industry, metallurgy, coal and other industries.In recent years,our factory continues to expand overseas markets, some competitive products are already exported to American and European countries, Africa, Middle East, etc , and well praised by customers.product applicationOur CertificateAll product process is strictly in accordance with international standards and power industry regulations. And the products are through the national, provincial power authorities testing, as well as CE certification! At present,0ur company has received ISO9001:2015 quality management system certification, ISO14001:2018 occupational health and safety management system certification, and ISO14001:2015 environmental management system certification,and also had got SGS certification.We has more than 20 patented technologies,such as The utility model patent of a frequency conversion series resonance test device,The utility model patent of Lightning impulse voltage testing equipment,The utility model patent of DC high voltage generator,The utility model patent of microcomputer relay protection tester,The utility model patent of High voltage switching characteristic tester., etc.4.certificateoverseas market & our serviceOverseas MarketOur products are sold to Europe, Asia, Africa, North and South America and Oceania, Middle East, etc.and are well received by customers.We had won the bids for the purchase of high-voltage no-partial discharge test equipment from the Polish state-owned insulator production plant, the Myanmar National Grid cable fault tester purchase project, and the high-voltage test equipment purchase project of a Russian power installation and test engineering company.We also sell to end customers, and a single device can also be sold. For example, there are power maintenance and installation companies in Indonesia, South Africa, Denmark, and South Korea, and universities and research institutions purchase and use our test equipment.At the same time, our sales targets also include agencies. At present, we already have cooperated with agents in Singapore, Israel, Mauritius , etc.We insist on providing customers with first-class products and first-class services with reliable product quality and perfect service team.5market-1Our service1.Strict factory testAll products will be assembled and test strictly accord with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.2.Providing technical materialsDuring the product acceptance, we provide the related manual sheets, packing list,qualified certificate labels, factory test reports and other technical documents.3. Support technical guidanceWe also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!After-sale service1.First-use responsibility systemAfter the product is delivered, the technician can guide the operation at site if the client requires, and be responsible for the first use of each part2.One year warrantyAll products warranty is 1year, life-time maintenance .During the warranty period, if any defects or damaged because of product’s quality, maintenance or replacement can be provided with free charge in order to let our client’s satisfied !3.TroubleshootingIf the troubleshooting is not difficult, and client can handle with it by themselves, we can offer the call-on line guide within 1 hour!If the troubleshooting is difficult to handle with for client, we can promise that the best solution can be provided within 24 hours!
Similar Product Recommend