Welcome Customer !

Membership

XwbooInstrumentationTesting MachineTransformer Testing MachinePower Quality Analyzer
  • $item.Title
  • $item.Title

Power Quality Analyzer

Wuhan Goldhome Hipot Electrical Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Transformer Testing Machine
Place of Origin
HuBei, WuHan
Measurement range: 45 ~ 55Hz, center frequency 50Hz, measurement conditions: signal basic component is not less than 80%F.S.Measurement error ≤ 0.01Hz;Input voltage range: 10V ~ 450V (special range can be customized)Input current range: 10A (other range according to user requirements)
I.Summary


The ideal power system to provide users with a sine wave voltage should be a constant frequency, and with the development of power electronic technology, DC power transmission, high power single-phase rectifier technology in the industrial sector and the electric equipment widely used, such as high-power silicon controlled devices, switching power supply, inverter and so on, these typical nonlinear load harmonic current from the power grid will be injected into the suction or, causing the distortion of grid voltage, the grid wave pollution, power quality deterioration, the additional losses increase, transmission capacity decreased, as can affect the power quality of the important factors.

In power grid, the three-phase load imbalance, power system resonance grounding will produce negative sequence, high-power rectifier and nonlinear equipment will produce harmonics. Negative sequence and harmonic wave seriously affect the quality of power supply, they first affect the safe operation of power equipment. Harmonics may cause resonance, resonance and high voltage across the capacitor, because the harmonic impedance of the capacitor is very small, so easy to overload and capacitor breakdown; harmonic current flowing into the transformer, the core loss increases; the harmonic current flowing into the motor, not only the core loss increases, and the rotor vibration, seriously affects the processing quality; the higher harmonics malfunction of protection devices, the system loss is increased; the power system harmonic voltage resonance overvoltage caused by the line, will breakdown equipment insulation. Negative sequence and harmonic wave not only have thermal effect, generate local heating, but also cause vibration of generator set, accompanied by noise, which seriously threaten the safe and stable operation of the unit.

II.Technical parameter



Frequency measurement

Measurement range: 45 ~ 55Hz, center frequency 50Hz, measurement conditions: signal basic component is not less than 80%F.S.

Measurement error ≤ 0.01Hz;

Input voltage range: 10V ~ 450V (special range can be customized)

Input current range: 10A (other range according to user requirements)

Fundamental voltage and current amplitude: the fundamental voltage allowed error less than 0.2%; Fundamental current allowed error less than 0.2%

Error of measuring phase difference between fundamental voltage and current: less than or equal to 0.5 degrees

Three-phase voltage unbalance: less than 0.2%

Three phase current unbalance: 0.5%;

Voltage deviation error is less than 0.2%

Power, power factor is less than 0.5%

flicker: 5%;

Voltage fluctuation: 5%.

Device interface (extended function): GPS hard timing, IRIG-B code time or second pulse timing signal.

Working hours: the internal battery 10 hours continuously


Concept editing broadcast

Power Quality (PowerQuality), strictly speaking, the main indicators for measuring power quality are voltage, frequency and waveform. In a general sense, it refers to high-quality power supply, including voltage quality, current quality, power supply quality, and electricity quality. Power quality problems can be defined as: voltage, current, or frequency deviations that cause electrical equipment to malfunction or fail to work properly, including frequency deviations, voltage deviations, voltage fluctuations and flicker, three-phase imbalance, instantaneous or transient transients Voltage, waveform distortion (harmonics), voltage sags, interruptions, swells, and power supply continuity, etc.

An ideal power system should supply power to users at a constant frequency (50 Hz) and a sine waveform, and at a prescribed voltage level (nominal voltage). In a three-phase AC power system, the voltage and current of each phase should be equal in amplitude, with a phase difference of 120. The symmetry state. Because the parameters of the system components (generators, transformers, circuits, etc.) are not ideally linear or symmetrical, the nature of the load varies and varies randomly, coupled with imperfect control methods, operation, external interference, and various faults. This ideal state does not exist in reality, and various problems in the operation of the power grid, electrical equipment and electricity consumption have arisen from this, and the concept of power quality (PowerQuality) has also been produced.

In a general sense, power quality refers to high-quality power supply. But so far, there are still different understandings of the technical meaning of power quality. This is because people look at problems from different perspectives. For example, power companies may simply regard power quality as voltage (deviation) and frequency (deviation). And use statistics to show that 9% of the power system power meets the quality requirements; power users may generally regard power quality as whether the load is normally supplied with power; while equipment manufacturers believe that qualified power quality refers to The power supply characteristics fully meet the needs of the normal design working conditions of electrical equipment, but in fact, the requirements for power supply characteristics of different manufacturers and different equipment may be very different. On the other hand, the understanding of power quality is also restricted by the development level of the power system, especially the performance and structure of the power load. [1]

Power quality index editing broadcast

Power quality indicators are specific descriptions of all aspects of power quality, and different indicators have different definitions. With reference to International Electrotechnical Commission standards, the basic phenomena that cause interference are classified as follows from the perspective of electromagnetic phenomena and interactions and influences.

a. Voltage interruption (interruption, outage): within a certain period of time, one or more phases completely lose voltage (less than 0.8 "standard unit value" is called power failure. According to the duration of time, it is divided into instantaneous power failure (0.5 cycle~3S) temporary power failure (3S~60S) and continuous power failure (greater than 60S).

b. Frequency deviation (frequency deviation): All countries have made clear regulations on this.

c. Voltage drop (sag) (voltage drop, dip): the duration is 0.5 cycles to 1 min, the amplitude is 0.1 to 0.9 (standard unit value), and the system frequency is still the nominal value.

d. Voltage rise (voltage swell, swell): The voltage (or current) duration is 0.5 cycles to 1 min, and the amplitude is 1.1 to 1.8 (standard unit value), and the system frequency is still the nominal value.

e. Instantaneous pulse (impulse): A voltage (or current) change that occurs in a very short time between two consecutive steady states. The instantaneous pulse can be a unidirectional pulse of any polarity, or the first peak of a damped oscillatory wave of any polarity.

f. Voltage fluctuation (fluctuation) and flicker (flicker): Voltage fluctuation is a regular change in the voltage within the envelope, or a series of random changes in voltage whose amplitude usually does not exceed the voltage range of 0.9 to 1.1. Flicker refers to the visual impact of voltage fluctuations on the lighting.

Comparison chart before and after power quality monitoring improvement

Comparison chart before and after power quality monitoring improvement

g. Voltage notch (notch): A voltage notch is a periodic voltage disturbance with a duration of less than 0.5 cycles. The voltage notch is mainly caused by the current switching from one phase to the other when the power electronic device undergoes an instantaneous short circuit between the related two phases. The frequency of voltage notch is very high, and it is difficult to detect it with conventional harmonic analysis equipment. This is the reason why this voltage disturbance has never been officially listed until recently.

h. Harmonics (harmonics): sinusoidal voltages or currents containing integer multiples of the fundamental frequency are called harmonics. Harmonics are caused by the non-linear characteristics of the power system and power load equipment.

i. Inter-harmonics: sinusoidal voltages or currents containing non-integer multiples of the fundamental frequency are called inter-harmonics. Fractional harmonics smaller than the fundamental frequency also belong to this category. Interharmonics can cause visual flicker in the lighting device.

j. Overvoltage (overvoltage): The voltage (or current) duration is greater than 1 min, the amplitude is 1.1 ~ 1.2 (standard unit value), and the system frequency is still the nominal value.

k. Undervoltage (undervoltage): The voltage (or current) duration is greater than 1min, the amplitude is 0.8~0.9 (standard unit value), and the system frequency is still the nominal value.

The power quality problems can be summarized as follows: ①Voltage fluctuation (fluctuation) and flicker (flicker); ②Harmonics (harmonics); ③Voltage three-phase unbalance (unbalance); ④Voltage drop (dip) and power supply Outage.


  Wuhan Goldhome Hi pot Electrical Co.,ltd(short for Goldhome Hi pot) was established in 2008, its predecessor was state-owned third industry enterprises, one of the earliest enterprises specially in develop, design and manufacture high voltage testing equipment in China.In 2016, merged with Wuhan Sang Electric Co., Ltd. , we realize advantageous compartmentalize and resources reorganization.Now it has become a high-tech enterprise integrating R&D, production, marketing installation and commissioning.1.our-historyOur FactoryGoldhome Hi pot is located in Huading Mould Industrial Park, Economic and Technical Development Zone, Wuhan City, Hubei Province, China, working area more than 4000 square meters.As a high-tech enterprise, we are supported by natural advantages from various research universities in Wuhan city. Goldhome Hi pot works closely with professors from State Grid Power Science Research Institute, Electrical Engineering Colleges of Wuhan University and other scientific research institutions, constantly improving technology and updating products . Now Goldhome Hi pot has more than 20 patented technologies, and many software Copyrights!2.our factory-1product and product applicationOur ProductOur advantage products included AC Resonant Test System, PD Free Test System, AC/DC Hi pot Tester, Primary Current Injection, VLF Hi pot Tester, transformer tester,impulse generator,Transformer oil tester,HV Switch gear Tester ,Insulation Tester,ground Resistance Tester,cable fault locator,relay test set,CT PT analyse,arr ester tester and sf6 gas analyzer,etc.Product ApplicationAll the performance indexes of above testing equipment can reach the leading level in China, widely used in power supply bureau, power plant, power construction, railway, petroleum, chemical industry, metallurgy, coal and other industries.In recent years,our factory continues to expand overseas markets, some competitive products are already exported to American and European countries, Africa, Middle East, etc , and well praised by customers.product applicationOur CertificateAll product process is strictly in accordance with international standards and power industry regulations. And the products are through the national, provincial power authorities testing, as well as CE certification! At present,0ur company has received ISO9001:2015 quality management system certification, ISO14001:2018 occupational health and safety management system certification, and ISO14001:2015 environmental management system certification,and also had got SGS certification.We has more than 20 patented technologies,such as The utility model patent of a frequency conversion series resonance test device,The utility model patent of Lightning impulse voltage testing equipment,The utility model patent of DC high voltage generator,The utility model patent of microcomputer relay protection tester,The utility model patent of High voltage switching characteristic tester., etc.4.certificateoverseas market & our serviceOverseas MarketOur products are sold to Europe, Asia, Africa, North and South America and Oceania, Middle East, etc.and are well received by customers.We had won the bids for the purchase of high-voltage no-partial discharge test equipment from the Polish state-owned insulator production plant, the Myanmar National Grid cable fault tester purchase project, and the high-voltage test equipment purchase project of a Russian power installation and test engineering company.We also sell to end customers, and a single device can also be sold. For example, there are power maintenance and installation companies in Indonesia, South Africa, Denmark, and South Korea, and universities and research institutions purchase and use our test equipment.At the same time, our sales targets also include agencies. At present, we already have cooperated with agents in Singapore, Israel, Mauritius , etc.We insist on providing customers with first-class products and first-class services with reliable product quality and perfect service team.5market-1Our service1.Strict factory testAll products will be assembled and test strictly accord with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.2.Providing technical materialsDuring the product acceptance, we provide the related manual sheets, packing list,qualified certificate labels, factory test reports and other technical documents.3. Support technical guidanceWe also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!After-sale service1.First-use responsibility systemAfter the product is delivered, the technician can guide the operation at site if the client requires, and be responsible for the first use of each part2.One year warrantyAll products warranty is 1year, life-time maintenance .During the warranty period, if any defects or damaged because of product’s quality, maintenance or replacement can be provided with free charge in order to let our client’s satisfied !3.TroubleshootingIf the troubleshooting is not difficult, and client can handle with it by themselves, we can offer the call-on line guide within 1 hour!If the troubleshooting is difficult to handle with for client, we can promise that the best solution can be provided within 24 hours!