Membership
Help
Wenzhou Modern Group Co., Ltd
Wenzhou Modern Group Co., Ltd
As the Internet of Things (IoT) and Intelligent Manufacturing (IM) develops, an increasing number of non-linear loads such as variable frequency drives (VFDs), servo VFDs, and high-frequency power devices are applied. This inevitably poses a negative impact on the power grid, such as transient shock, high-frequency harmonic current, reactive current and 3-phase voltage unbalance.
Power Quality Issues | Harm to Devices | Benefits after Management |
Excessive reactive current | Reduced efficiency in power generation and transmission and a fine imposed by the Power Sector to related enterprises; Sharp decline in the utilization of input transformers and unnecessary increase in device costs and basic electricity payments | Ensure that system power factors meet national standards, thereby avoiding fines arising from a low power factor; Decrease in-house device power consumption, improve transformer utilization, and reduce electricity payments. |
Excessive harmonic current | Voltage distortion generated on the power grid and inability to use related devices on the grid; Shorter device service life, e.g., unexpected heating, accelerated aging and reduced service life of a capacitor, and more seriously, capacitor bulging, breakdown or explosion | Improve power use safety and system reliability; Extend device service life and reduce device maintenance costs; Minimize the disturbance of harmonic current on precision instruments. |
3-phase voltage unbalance | Improper running of devices on the unbalanced line, and more seriously, device failure | Enhance power supply quality of enterprise equipment, improve reliability in device operation, and reduce economic loss; Suppress neutral current and prevent overcurrent from damaging other lines. |
Voltage sag | Unexpected shutdown of on-going manufacturing devices, product quality decline or production line hold-ups; Machinery damage and electrical device burnout, and more seriously, personal accidents; Sensitive-device data loss and huge economic loss | Ensure a continuous production line, and avoid possible productivity drop due to device shutdown; Optimize device power use quality, and ensure product quality; Extend service life of manufacturing equipment. |



Our modular power quality products include: Static Var Generators (SVGs), Advanced SVGs (ASVGs) and Active Power Filters (APFs). They have features such as high power density, enhanced reliability, optimized performance, high utilization and unique designs. For use in different application scenarios, there are three way to install them: drawer style, wall-mounted style and upright style.
Drawer style |
Wall-mounted |
Upright |
2-Units wall mounted
2-Units drawer style |
Integrated modular cabinet |
Our modular power quality regulators:
Industry-first dust-proof module at the control layer: The control section is separated from the power section. The control layer applies a fully closed dust-proof design, with no vent holes at two sides, front and back, thus obtaining an excellent sealing; while at the air cooling layer, critical power units are cooled by the power layer, thus achieving a superior device cooling performance. In addition, the control layer reaches a protection class of IP6X and has withstood the third-party lab testing. This isolates the control section from being polluted by the outer world. Besides, we employ an industry-grade hardware design, which further improves security and reliability.

At the dust-proof certification test |
After the dust-proof certification test |
Use of a separate control scheme for each IGBT, which is much more reliable because: each IGBT is equipped with a set of drives and a hall element, and in the case that the IGBT on one side fails, the device still could offer 50% of the rated output capacity.

Providing a soft-start relay and resistor between a filter capacitor and the power grid, to ensure that when a device fails, the filter capacitor breaks away from the grid, without posing any secondary impact on the grid.

Quicker response: Use of a Second-Order Generalized Integration (SOGI) algorithm achieves a global response time of less than 2ms, making it possible to accurately tract how harmonic content and reactive content change in the power grid and prevent over-compensation and under-compensation.
![]() | ![]() |
In the response test of a sudden load rise, the oscillometer record shows that the global response time on the display is 1.36ms.
In the response test of a sudden load drop, the oscillometer record shows that the global response time on the display is 1.96ms.
Advanced harmonic suppression technology: Quickly suppresses the harmonic state in less than 1s after a device detects that harmonic current is inevitable in the power grid, making sure that the device will not be turned off entirely so that it can go on performing compensation for the system. | ![]() |
Low ripple output: An interleaving-based low-ripple control technology achieves a smooth waveform even for a 60th harmonic output. | ![]() |
Our modular power quality regulators are connected in parallel on the power grid. By using an external CT to detect in real-time the load current on the grid, with the help of DSP/FPGA/CPLD chips, and in cooperation with the latest harmonic/reactive-component extraction technology, our regulators quickly obtain the harmonic or reactive content in the load current upon analysis, then generate PWM pulses based on the value that has been set, drive the bi-directional converter made up of three-level IGBT modules, and generate a compensation current that meets the grid requirement. Finally, they realize dynamic, precise compensation for harmonic or reactive current and improve the quality in power supplying.

Inductive reactive-current compensation |
Capacitive reactive-current compensation |

Transformer Capacity (kVA) | APF Capacity (3-Phase 3-Wire) | APF Capacity (3-Phase 4-Wire) |
1000 | 200A | 300A |
1250 | 300A | 400A |
1600 | 400A | 500A |
Remarks | 1. For use in harsh environment, we recommend industry-specific cabinet-style products; 2. For use in scenarios where harmonic current and reactive current are excessively large, configure our products based on actual calculation or in-site test data. | |
Model | APF 20A | APF 35A | APF 50A | APF 100A | APF 125A | APF 150A |
System Parameters | ||||||
Grid voltage | 400V (-40%‒+20%) | |||||
Grid frequency | 50 Hz/60Hz (±10%) | |||||
Pieces to be integrated | No limit | |||||
Global efficiency | Up to 98% | |||||
Wiring mode | 3-phase 3-wire/3-phase 4-wire | |||||
Heat loss | <2% | |||||
CT | 150/5‒10000/5 | |||||
Connection mode | Back connection/Top connection | |||||
Air in/out | Front to back/Top to bottom | |||||
Performance Indicators | ||||||
Response time | <2ms | |||||
Harmonic compensation order | 2‒51 | |||||
Cooling mode | Intelligent air cooling | |||||
Noise indicator | <58dB | |||||
Fixing mode | Drawer style, wall-mounted style and upright style | |||||
Dimensions (W*D*H mm) | Drawer style: 442*485*90 Wall-mounted:442*90*485 | Drawer style: 500*590*150 Wall-mounted:505*175*640 Upright: 170*525*590 | Drawer style: 500*590*170 Wall-mounted: 505*195*640 Upright: 170*525*590 | |||
Net weight | 20kg | 35kg | 45kg | |||
Environment Parameters | ||||||
Altitude | ≤2000m, 2000m‒4000m de-rating | |||||
Operating temperature | -10℃‒+50℃ (>40℃, use upon de-rating) | |||||
Relative humidity | 5%‒95%, non-condensing | |||||
Transformer Capacity (kVA) | CosФ | ||||
| <0.5 | 0.5‒0.6 | 0.6‒0.7 | 0.7‒0.8 | 0.8‒0.9 |
1000 | 550kvar | 550kvar | 450kvar | 350kvar | 200kvar |
1250 | 600kvar | 600kvar | 550kvar | 450kvar | 235kvar |
1600 | 800kvar | 800kvar | 700kvar | 550kvar | 300kvar |
Remarks | 1. For use in harsh environment, we recommend industry-specific cabinet-style products; 2. For use in scenarios where harmonic current and reactive current are excessively large, configure our products based on actual calculation or in-site test data. | ||||
Model | ASVG15kvar | ASVG25kvar | ASVG35kvar | ASVG50kvar | ASVG70kvar | ASVG100kvar |
System Parameters | ||||||
Grid voltage | 400V (-40%‒+20%) | |||||
Grid frequency | 50Hz/60Hz (±10%) | |||||
Pieces to be integrated | No limit | |||||
Efficiency | Up to 98% | |||||
Wiring mode | 3-phase 3-wire/3-phase 4-wire | |||||
Heat loss | <2% | |||||
CT | 150/5‒10000/5 | |||||
Connection mode | Connect from the back/top | |||||
Air in/out | Front to back/Top to bottom | |||||
Performance Indicators | ||||||
Global response time | <2ms | |||||
Harmonic compensation order | 2‒23 | |||||
Power factor | Adjustable from -1‒1 | |||||
Cooling mode | Intelligent air cooling | |||||
Noise | <58dB | |||||
Fixing mode | Drawer style, wall-mounted style and upright style | |||||
Dimensions (W*D*H mm) | Drawer style: 442*485*90 Wall-mounted: 442*90*485 | Drawer style: 500*590*150 Wall-mounted: 505*175*640 Upright: 170*525*590 | Drawer style: 500*590*170 Wall-mounted: 505*195*640 Upright: 170*525*590 | |||
Net weight | 20kg | 35kg | 45kg | |||
Environment Parameters | ||||||
Altitude | ≤2000m; 2000m‒4000m de-rating | |||||
Operating temperature | -10℃‒+50℃ (>40℃, use upon de-rating) | |||||
Relative humidity | 5%‒95%, non-condensing | |||||
*Allocating rated power for compensation: You can select a proportion of the global rated power based on your settings to compensate for harmonic current and reactive current.
99% indicates that all of the global rated power is used for harmonics compensation.
Model | SVG 15kvar | SVG 25kvar | SVG 35kvar | SVG 50kvar | SVG 70kvar | SVG100kvar |
System Parameters | ||||||
Grid voltage | 400V (-40%‒+20%) | |||||
Grid frequency | 50Hz/60Hz (±10%) | |||||
Pieces to be integrated | No limit | |||||
Efficiency | Up to 98% | |||||
Wiring mode | 3-phase 3-wire/3-phase 4-wire | |||||
Heat loss | <2% | |||||
CT | 150/5‒10000/5 | |||||
Connection mode | Connect from the back/top | |||||
Air in/out | Front to back/Top to bottom | |||||
Performance Indicators | ||||||
Global response time | <2ms | |||||
Power factor | Adjustable from -1‒1 | |||||
Cooling mode | Intelligent air cooling | |||||
Noise | <58dB | |||||
Fixing mode | Drawer style, wall-mounted style and upright style | |||||
Dimension (W*D*H mm) | Drawer style: 442*485*90 Wall-mounted: 442*90*485 | Drawer style: 500*590*150 Wall-mounted: 505*175*640 Upright: 170*525*590 | Drawer style: 500*590*170 Wall-mounted: 505*195*640 Upright: 170*525*590 | |||
Net weight | 20kg | 35kg | 45kg | |||
Environment Parameters | ||||||
Altitude | ≤2000m, 2000m‒4000m de-rating | |||||
Operating temperature | -10℃‒+50℃ (>40℃, use upon de-rating) | |||||
Relative humidity | 5%‒95%, non-condensing | |||||
Front view |
Front view |
Left view |
Top view |
Front view |
Front view |
Left view |
Top view |
Front view |
Left view |
Back view |
Top view | ![]() | |
Front view |
Left view |
Back view |
Top view | ![]() | |
Front view |
Left view |
Back view |
Top view | ![]() | |
Front view |
Left view |
Back view |
Top view | ![]() | |
Front view |
Left view |
Top view |
Front view |
Left view |
Top view |
Front view |
Left view |
Top view |
Front view |
Left view |
Top view |
Front view |
Side view |
Back view |
Front view |
Side view |
Back view |
Module installation view |
Top view |