Product Specifications of PT112/PT123/PT133 Melt Extruder Pressure Transducer
Product model: PT112 (straight rod type), PT123 (hose type), PT133 (temperature and pressure double measurement type)
2.1 Standard melt extruder pressure transducer at high temperatures: PT112/PT123/PT133
Definition: melt extruder pressure transducer with a 3.33 mV/V output signal.
2.2 Standard melt extruder pressure transmitters at high temperatures: PT112B, PT123B, and PT133B
Definition: The output signal is 0-10 Vdc, 0-5 Vdc, and (4-20) mA.

1. Stainless steel welding
2. Easy to install
3. Zero and span adjustable
4. Various amplified signals are optional
5. Internal 80% shunt calibration
6. Good stability and anti-jamming capability
7. Excellent stability and repetition
It is suitable for pressure measurement and control of high-temperature fluid media in rubber and plastic, chemical fiber, steam, Textile, Paper, Blowing machine, petrochemical, and other industries.
The Standard Melt Extruder Pressure Transducer (Transmitter) is an instrument to measure melt pressure in high-temperature areas (referred to as a sensor and transmitter) with a digital-analog circuit design. Please follow the instructions below for storage and operation can ensure the maximum service life of the product. The products comply with the national JJG860-2015 “Pressure sensor (static) verification Regulations” and JJG882-2019 “Pressure transmitter Verification Regulations”.
Technical Parameters
| Performance Parameter | High-Temperature Melt Extruder Pressure Transducer PT112, PT123, PT133 | High-Temperature Melt Extruder Pressure Transmitter PT112B, PT123B, PT133B |
| Output Signal | 3.33 mV/V | (4-20) mA Two-wire system | 3-wire (0-10) Vdc, 3-wire (0-5) Vdc |
| Supply Voltage | (6-12) Vdc (10 Vdc recommended) | (10-36) Vdc | (12-36) Vdc |
| Load resistance (Ω) | | <(Supply voltage-10)/0.02 | >10k |
| Calibration signal: 80% F.S. |
| Basic Error (%) | ±0.5% (level 0.5), ±0.25% (level 0.25) (expressed as a percentage of the full-scale output value) |
| Max. Operating Temp | 0~260℃ (max 400℃) |
| Electric connector | 1/2 NPT explosion-proof gland cable |
| Process connector | 1/2″-20UNF, M14 x 1.5, M18 x 1.5, M22 x 1.5, G3/4 (Customer design) |
| Repeatability shall not be greater than the absolute value of the basic error, and the return difference shall not be greater than the absolute value of the basic error. |
Transportation And Storage
1- The product is normally packaged individually, and when stored, please carefully repackage the packaging it originally came with. 3.2 At the front thread of the rigid rod, the induction diaphragm is protected by a protective cap, which should be tightened at any time during storage and only opened when using the installation. It is strictly prohibited to press the diaphragm with sharp materials.
2- Long-term storage needs to meet the following conditions:
① Ambient temperature: -20~85℃, relative humidity: 0%~99% R.H.
② Not exposed to rain or affected by water seepage/leakage.
③ Vibration and shock are kept to a minimum.
Product Installation Hole
Before installing the product, make sure that the mounting holes are machined to the correct size and that the holes are free of burrs.

Correct Installation Mode

Use our professional mounting bracket to fix the product, the fixing position should avoid vibration and installation in a strong magnetic environment, and should not be exposed to rain or water seepage/leakage, the temperature should not exceed 85℃.