Volcano strives to bring our customers the latest technology and competitive pricing and best service for distribution automatic.
The ZW32 series automatic circuit reclosers can use on overhead distribution lines as well as distribution substation applications for all voltage classes 11kV up to 38kV at 50/60HZ power system. and its rated current can reach 1250A.
The ZW32 series automatic circuit reclosers integrates the functions of control, protection, measurement, communication, fault detection, on-line monitoring of closing or opening.

Main technical data
| No. | Item | Unit | Data for ZW32-12KV | Data for ZW32-15KV | |||||
| 1 | Rated Voltage | KV | 12 | 15 | |||||
| 2 | Rated insulation level (phase to ground, phase to phase) | 1 min Frequency withstand voltage | Dry | KV | 42 | 50 | |||
| Wet | 34 | 45 | |||||||
| Lighting Impulse Withstand Voltage(Peak) | KV | 75 | 110 | ||||||
| 3 | Medium Interruption: | Vacuum | |||||||
| 4 | Medium isolation: | Solid polymer | |||||||
| 5 | Mechanism of operation (closing and shot): | Magnetic | |||||||
| 6 | Assembly: | Suitable weather for substation | |||||||
| 7 | Environmental operating temperature: | FROM -40ºC-+50ºC | |||||||
| 8 | Position indicator: Green-closed; Open-red | ||||||||
| 9 | Minimum distance of contouring of the insulation | MM | 400 | 600 | |||||
| 10 | Rated Frequency | Hz | 50/60 | ||||||
| 11 | Rated Current | A | 630/800/1250 | ||||||
| 12 | Rated Min Start-up Current | Numerical | A | adjustable | |||||
| Permissible deviation | % | ±10 | |||||||
| 13 | Rated Fault Interrupter Capacity | KA/3s | 12.5/20 | ||||||
| 14 | Rated Fault Symmetrical Making Current | KA | 12.5/20 | ||||||
| 15 | Rated Short-Time Withstand Current | KA | 12.5/20 | ||||||
| 16 | Rated Peak Withstand Current | KA | 12.5/20 | ||||||
| 17 | Interrupting Time(Max) (Cycle) | s | No more than 4 | ||||||
| 18 | The conditions of different phase earthed fault short-circuit breaking current | KA | 17.3 | ||||||
| 19 | Rated Cable Charging Breaking current | A | 25 | ||||||
| 20 | Rated Operating Sequence | O-0.1s-CO-2s-CO-2s-CO-C | |||||||
| 21 | Rated Operation Voltage | V | AC/DC110/125/220/240 | ||||||
| 22 | Rated Short-Circuit Current Breaking Times | Time | |||||||
| 90%~99% Rated Short-Circuit Current volume | 16 | ||||||||
| 45%~55% Rated Short-Circuit Current volume | 44 | ||||||||
| 15%~20% Rated Short-Circuit Current volume | 56 | ||||||||
| 23 | Mechanical Life (Mechanical stability) | Time/Unit Operation | 15000 | ||||||
| 24 | Current Transformer | Primary Rated Current | A | 600/1000 | |||||
| Secondary Rated Current | 1 or 5 | ||||||||
| Accuracy Grade | CL | 0.2/5P20 | |||||||
| Capability | VA | 15 | |||||||
| 25 | Special Manual Closing Mechanism | optional | |||||||
| 26 | Earthing | Solidly Earthed | |||||||
PRODUCT SCHEMATIC DIAGRAM