Membership
Help
ACE METER TECHNOLOGY CO.,LIMITED
ACE METER TECHNOLOGY CO.,LIMITED
RS485 Electromagnetic Flow Meter
The RS485 Electromagnetic Flow Meter is smart flow meter with inbuilt RS485 modular. The system can communicate with the flow meter by RS485 protocol.The RS485 protocol can feed back the data by the code received from the protocol like the current flow rate, accumulated flow amount.The RS485 Electromagnetic Flow Meter can be used in various control system and work with wireless signal modular like GSM,LORAWAN,WIFI modular.Now the RS485 electromagnetic flow meter has become a good selection for many IOT projects.


| Measure Medium | Water,Sewage,Acid,Alkali,Slurry,Milk | |||
| Nominal diameter | 15-500mm | |||
| Degree of accuracy | ±0.5%R | |||
| Medium conductivity | ≥5uS/cm,Actual conductivity≥30uS/cm | |||
| Nominal pressure | 1.0MPa | 1.6MPa | 2.5MPa | 4.0MPa |
| DN15-DN500 | DN15-DN500 | DN15-DN500 | DN15-DN50 | |
| Highest medium temperature | Compact type | +80℃ | ||
| Remote type | CR chloroprene rubber liner (CR) | +80℃ | ||
| Polytetrafluoroethylene lining(F4) | +120℃ | |||
| Politef lining(F46) | +120℃ | |||
| Teflon(PFA) | +180℃ | |||
| Fluorosilicone rubber(FVMQ) | +250℃ | |||
| Output signal | 4-20mA;Pulse/Frequency 2kHz(Default),5KHz(Max) | |||
| Supply voltage | 110/220VAC(100-240VAC),50Hz/60Hz;24VDC ±10% | |||
| Communication | RS-485,Support standard Modbus-RTU protocol;GPRS | |||
| Electrode material | Stainless steel 316L,Hastelloy C,Hastelloy B,titanium, tantalum, platinum | |||
| Level of protection | Remote type | IP68,IP65 | ||
| Compact type | IP65 | |||
RS485 Electromagnetic Flow Meter Product advantage
High Precision
Super large capacitance,
anti high voltage 450V,
PHILPS military level CPU,
Independent AD chip,
EMC standard anti-jamming.
Basic function
High frequency square wave excitation, excitation frequency: 1 ≤ 2 power frequency (suitable for slurry measurement) (selection);
The air traffic control measurement function without additional electrode, continuous measurement, fixed value alarm;
The measuring range of velocity is 0.1-15 m / s, and the resolution of velocity is 0.5 mm / s.
There are three accumulators in the interior, which can be recorded separately: positive total, reverse total and total difference.




RS485 Electromagnetic Flow Meter