Welcome Customer !

Membership

XwbooInstrumentationTesting MachineOther Testing MachinesSecondary Injection Relay Test Kit
  • $item.Title
  • $item.Title

Secondary Injection Relay Test Kit

Wuhan Goldhome Hipot Electrical Co., Ltd.

Model
Nature of the Manufacturer
Manufacturer
Product Category
Other Testing Machines
Place of Origin
HuBei, WuHan
AC current output: 6 channels, each 30A / 450VA, six-phase parallel 180AAC voltage output: 6 channels, each 120V / 80VA, line voltage 240VOutput accuracy: 0.2% (within the main measuring range)DC current output: 6 channels, each ±10A/200VADC voltage output: 6 channels, each ±160V/70VAOutput accuracy: 0.2% (within the main measuring range)Phase: 0~360°Phase accuracy: 0.2°Output frequency: 0~1000Hz
Function and application


Six phase Secondary Injection Relay Test Kit can verify various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, and It can simulate a variety of complex transient, permanent, and conversion faults for the entire set of tests.


The main technical parameters


AC current output: 6 channels, each 30A / 450VA, six-phase parallel 180A

AC voltage output: 6 channels, each 120V / 80VA, line voltage 240V

Output accuracy: 0.2% (within the main measuring range)

DC current output: 6 channels, each ±10A/200VA

DC voltage output: 6 channels, each ±160V/70VA

Output accuracy: 0.2% (within the main measuring range)

Phase: 0~360°

Phase accuracy: 0.2°

Output frequency: 0~1000Hz

Frequency accuracy: 0.001Hz

Superimposed harmonics: 0~20 times

Open input: 8 channels

Output: 4 pairs

Independent DC: DC110/220V, rated current 1.5A


Detail technical parameter


AC current output

Each phase output (RMS) when six phase current output 0~30A output precision 0.1 grade

Each phase output(RMS) when three phase current output 0~60A

Six phase parallel current output (RMS) 0~180A

Long-term allowable working value of phase current (RMS) 10A

Max output power of phase current 450VA

Max output power when six phase parallel current output 1000VA

Allowed working time when six phase parallel current max output 10s

Frequency range(fundamental wave) 0~1000Hz

Harmonic order 0~20

DC current output

Current output 0~±10A / phase output precision 0.2 grade

The maximum load volatage output 20V

AC voltage output

Phase voltage output(RMS) 0~120V output precision 0.1 grade

Line voltage output (RMS) 0~240V

Output power of phase voltage/ line voltage 80VA / 100VA

Frequency range(fundamental wave) 0~1000Hz

Harmonic order 0~20

DC voltage output

Output amplitude of phase voltage 0~±160V output precision 0.2 grade

Output amplitude of line voltage 0~±320V

Output power of phase voltage/ line voltage 70VA / 140VA

Input & output

8 channels input

Free contact 1~20mA,24V

Electric potential contacts "0":0 ~ +6V; "1":+11 V ~ +250 V

4 channels output DC:220 V/0.2 A;AC:220 V/0.5 A

Time measurment range

0.1ms ~ 9999s, measurement accuracy <0.1ms

application -secondary  injection test  set


Technical characteristics


1.Flexible combination of voltage and current output.

Output up to six-phase voltage and six-phase current,can be combined to achieve conventional four-phase voltage three-phase current type, or six-phase voltage type, or six-phase current type, even 12-phase type output modes, compatible with traditional Various test methods.

2.Convenient and quick operation.

The device panel is equipped with a trackball mouse, optimized keyboard and large-screen TFT LCD display. Built-in all English Windows platform operating software.

3.Dual operation mode.

In addition to stand-alone operation, the Secondary Injection Relay Test Kit can also be connected to a laptop or desktop for operation. The functions of the two modes are completely the same.

4.New high-fidelity linear power amplifier.

The output terminal has always insisted on using high-fidelity, high-reliability modular linear power amplifiers instead of switching power amplifiers, with excellent performance. It will not produce High-mid frequency interference to disturb the test, and it ensures that the smoothing accuracy of waveform in the whole course from large current to tiny current is excellent.

4.High-performance host.

The output part is controlled by DSP, with fast operation speed, strong real-time digital signal processing ability, wide bandwidth and high resolution D/A conversion control. The output waveform has the features of high precision, small distortion and good linearity. With using a large number of advanced technology and precision components and materials and the structure of professional design, the Secondary Injection Relay Test Kit has the features of small volume, light weight, full function, easy to carry, boot can work, flow test is very convenient.

5.Powerful software functions.

The six phase Secondary Injection Relay Test Kit can completeall all kinds of high automatic validation work which is large and complex. It can easily test and scan various protection settings, perform fault playback, real-time store test data, display vector graphics, and print reports online. The 6-phase current can facilitate the three-phase differential protection test.

6.With independent dedicated DC power output.

There is a 110V and 220V dedicated adjustable DC power output.

7.Rich contacts .

10 contact inputs and 4 empty contact outputs.

The input contacts are compatible with the empty contacts and 0-250V potential contacts, which can be intelligently and automatically identified.

8.Perfect self-protection function.

The design of the heat dissipation structure is reasonable, the hardware protection measures are reliable and complete,it has the power soft start function and the software of the fault self-diagnosis and the output latch function.


Index of Secondary Injection Relay Test Kit


This index is intended to guide the test personnel: Which modules of the "relay protection" series software can be used to complete the test of relay protection devices in different kinds.

Relay test:

Relay protection typeTest itemsSuggested test modules

Signal relay

Corresponding test items

DC test
AC DC test

Time relay

Intermediate relay

Reclosing relay

Other DC voltage and current relays

Current relay

Corresponding test items

AC test

Over(under)voltage relay

Sequence component relay

Synchronization check (or phase comparison) relay

Inverse time current relay

Differential relay

DC magnetic properties

Differential relay, differential harmonic, AC and DC test, harmonic test

Harmonic braking characteristics


Proportional braking characteristics

Differential relay, AC test

Power (direction) relay

Corresponding test items

Power direction and impedance, AC test

Impedance relay



Synchronous relay

Corresponding test items

Simultaneous test, AC test

Frequency relay

Corresponding test items

Frequency and high-low cycle

For the test items of microcomputer protection and the selection of corresponding test modules, please contact us for details!

1(001)

Introduction on Common Functions in Menu Bar of the Secondary Injection Relay Test Kit

Name or symbols of menu items in every testing module are the same, and its definition and function are almost identiacal. We take the ‘AC Test module as example for introduction, which can be applied for all functional modules.

— Opening file:The shortcut key is Ctrl+O, which is used for calling out testing parameters saved in appointed file and showing the parameters on software interface. If clicking this function, the testing parameters of current module will be saved as the following default path :E:/ Relaytestar/Paraame of current module/.

● Saving parameters:The shortcut key is Ctrl+S, which is used for saving the testing parameters on software interface and call out them again by using ‘Opening parameter’ later. Data will be saved in the default file of the current module.

● Reporting Test:Shortcut key is Ctrl+R, which is used for calling out the test report saved in appointed file. The contents of test report will be displayed in the test report window and revising or printing the test report can be completed in this window. After every test, a dialog box will be ejected by the system to save the test report. The report will be saved as the following defaulted path: E:/ Relaytestar/Test Reportame of current module/

● Exit:Shortcut key is Ctrl+X,which is used for exiting current testing module。

● Start Test:It has identical function as the run key,which is used for starting the test.

● Stop Test:It has identical function as the ESC key, which is used for ending the test normally or compelled terminating program running.

● Short Circuit Calculation:After clicking it, a ‘short circuit calculation’ dialog box will be opened, which is used for short circuit calculation and automatically fill the interface with the calculated results when fault occurs just like the right chart shows. Note that zero sequence compensating factors must be set correctly when the fault type is grounding fault.




Service and Support


Factory Release Test

Products are operated in correct way strictly according to production process .

About qualified product, inspector will issue factory test report and certification of quality .

Sub-quality products are prohibitted to leave factory .

Hand-over Technical Documents

Wuhan Goldhome Hipot Electrical Co.,ltd will afford Operation Manual, Packing List, Cerficiation of quality while in prdoucts acceptance.

Technical Guidance

After delivering device customers,Wuhan Goldhome Hipot Electrical Co.,ltd can provide systematic technical training, to ensure operator know the operation produce maintenance and trouble-shooting , and able to make test on site .


After-sale Service


First Time Use guidance

For the first time use, technical staff will guide customer how to make testing at site.


One-years Warranty

The warranty period of all equipment is one year, lifetime maintenance.

During warranty period, free maintenance or replacement are provided timely for any quality problem . Finally we will afford customer a satisfactory solution, whether repair , replace or return it back .


Trouble-shooting

fault that users can solve by themselves, we guarantee to give timely telephone guidance and bear the necessary cost .

If meet any fault not impossible to be solved by end-user, we will afford the best solution within 24 hours . Produce will be repaired within 10 days and delivery back to customer .

  Wuhan Goldhome Hi pot Electrical Co.,ltd(short for Goldhome Hi pot) was established in 2008, its predecessor was state-owned third industry enterprises, one of the earliest enterprises specially in develop, design and manufacture high voltage testing equipment in China.In 2016, merged with Wuhan Sang Electric Co., Ltd. , we realize advantageous compartmentalize and resources reorganization.Now it has become a high-tech enterprise integrating R&D, production, marketing installation and commissioning.1.our-historyOur FactoryGoldhome Hi pot is located in Huading Mould Industrial Park, Economic and Technical Development Zone, Wuhan City, Hubei Province, China, working area more than 4000 square meters.As a high-tech enterprise, we are supported by natural advantages from various research universities in Wuhan city. Goldhome Hi pot works closely with professors from State Grid Power Science Research Institute, Electrical Engineering Colleges of Wuhan University and other scientific research institutions, constantly improving technology and updating products . Now Goldhome Hi pot has more than 20 patented technologies, and many software Copyrights!2.our factory-1product and product applicationOur ProductOur advantage products included AC Resonant Test System, PD Free Test System, AC/DC Hi pot Tester, Primary Current Injection, VLF Hi pot Tester, transformer tester,impulse generator,Transformer oil tester,HV Switch gear Tester ,Insulation Tester,ground Resistance Tester,cable fault locator,relay test set,CT PT analyse,arr ester tester and sf6 gas analyzer,etc.Product ApplicationAll the performance indexes of above testing equipment can reach the leading level in China, widely used in power supply bureau, power plant, power construction, railway, petroleum, chemical industry, metallurgy, coal and other industries.In recent years,our factory continues to expand overseas markets, some competitive products are already exported to American and European countries, Africa, Middle East, etc , and well praised by customers.product applicationOur CertificateAll product process is strictly in accordance with international standards and power industry regulations. And the products are through the national, provincial power authorities testing, as well as CE certification! At present,0ur company has received ISO9001:2015 quality management system certification, ISO14001:2018 occupational health and safety management system certification, and ISO14001:2015 environmental management system certification,and also had got SGS certification.We has more than 20 patented technologies,such as The utility model patent of a frequency conversion series resonance test device,The utility model patent of Lightning impulse voltage testing equipment,The utility model patent of DC high voltage generator,The utility model patent of microcomputer relay protection tester,The utility model patent of High voltage switching characteristic tester., etc.4.certificateoverseas market & our serviceOverseas MarketOur products are sold to Europe, Asia, Africa, North and South America and Oceania, Middle East, etc.and are well received by customers.We had won the bids for the purchase of high-voltage no-partial discharge test equipment from the Polish state-owned insulator production plant, the Myanmar National Grid cable fault tester purchase project, and the high-voltage test equipment purchase project of a Russian power installation and test engineering company.We also sell to end customers, and a single device can also be sold. For example, there are power maintenance and installation companies in Indonesia, South Africa, Denmark, and South Korea, and universities and research institutions purchase and use our test equipment.At the same time, our sales targets also include agencies. At present, we already have cooperated with agents in Singapore, Israel, Mauritius , etc.We insist on providing customers with first-class products and first-class services with reliable product quality and perfect service team.5market-1Our service1.Strict factory testAll products will be assembled and test strictly accord with our product process standard. All qualified products will be issued factory release reports and certificate labels.Defect products or non-qualified products won’t be allowed to make deliver.2.Providing technical materialsDuring the product acceptance, we provide the related manual sheets, packing list,qualified certificate labels, factory test reports and other technical documents.3. Support technical guidanceWe also provide the training for the operators. Complete training includes the skilled operations of our equipment, maintenance and troubleshooting . it also ranges the commissioning and test of our products at site!After-sale service1.First-use responsibility systemAfter the product is delivered, the technician can guide the operation at site if the client requires, and be responsible for the first use of each part2.One year warrantyAll products warranty is 1year, life-time maintenance .During the warranty period, if any defects or damaged because of product’s quality, maintenance or replacement can be provided with free charge in order to let our client’s satisfied !3.TroubleshootingIf the troubleshooting is not difficult, and client can handle with it by themselves, we can offer the call-on line guide within 1 hour!If the troubleshooting is difficult to handle with for client, we can promise that the best solution can be provided within 24 hours!
Similar Product Recommend