  1. Force, Accelerometer, Displacement, Pressure, Angular Rate, Voltage, Current Sensors Calibration System.
  2. According to JJF, GB/T, ISO, SAE, etc. Regulation;
  3. Static Calibration;
  4. Calibration Range by Required;
  5. Calibration Fixture Supplied;
  6. Calibration Parameters by Required.
  SCS-XXX serials calibration system mainly focus on vehicle safety test field, including dummy loadcell, seatbelt loadcell, pedestrian protection legform loadcell, dummy and vehicle body accelerometers, kinds of displacement (as IR-TRACC), Gyro, door pressure sensor, airbag pressure sensor, airbag squib current sensors, and EV/HEV high voltage and current sensor. These calibration systems are suitable to the sensors of general industry.

Specification (Force Calibration System SCS-FO):
NameUnitValue
RangeKN≤45
Loading Method/Step/Continues
Cal. IndexSensitivity, offset, Non-Linearity, Hysteresis, Crosstalk, Shunt.
ExcitationV2.5/3.3/5/10
Seatbelt Loadcell Cal.ISO 17242Support
Sensor Test ChainAmp≤10VSupport
 
Specification (Accelerometer Calibration System SCS-AC):
NameUnitValue
Amp. Cal. Rangeg10~1000
Freq. Cal. RangeHz10~10000
RegulationISO16063GB/T20485
Cal. IndexSensitivity, Deviation, Offset
Excitation for PRV5/10
Excitation for IEPEmA4
PE AccelerometerpC inputSupport
Sensor with Test ChainAmp≤10VSupport
 
Specification (Displacement Calibration System SCS-DS):
NameUnitValue
Cal. Rangemm<2000
Cal. ObjectsH3/ES2/WS/THRO/Q Serial Dummy Rib Displacement, Knee Pot. and Other String Pot.
Cal. IndexSensitivity, Non-Linearity
 
Specification (Pressure Calibration System SCS-PR):
NameUnitValue
Cal. RangekPa≤600
Loading MethodStaticJJF1640-2017
Cal. IndexSensitivity. Offset. Non-Lin. Hys.
ExcitationV5/10
 
Specification (Angular Rate Calibration System SCS-AV):
NameUnitValue
Cal. Rangedeg/sec≤18000
Loading MethodStaticJJF1535-2015
Cal. IndexSensitivity. Offset. Non-Lin. Hys.
ExcitationV5/10
 
Specification (Voltage Calibration System SCS-VO):
NameUnitValue
Cal. RangeV≤1000
Loading MethodStaticDAQ by Step
Cal. IndexSensitivity. Offset. Non-Lin. Hys.
ExcitationV5/10
3-Ch Voltage SensorOptional for EV/HEV V1,V2,Vb
 
Specification (Current Calibration System SCS-CU):
NameUnitValue
Cal. RangeA≤2500
Cal. IndexSensitivity. Offset. Non-Lin. Hys.
Excitation/Power SupplyV5/10/±15/24
 
Note: Ampere-turn Method applied Above 100A.