Description:
FLN36-12D, FLRN36-12D sulfur hexafluoride load switch, load switch-fuse combination, and loadable cable head load switch are designed and developed by our company by absorbing foreign advanced technology and combining with the operating requirements of our country.
The product has three positions of arc extinguishing chamber, which is reliable in interlocking , high insulation strength at breakage, large climbing distance design, and the outlet end is protected by voltage sharing protective cover.
The switch has a special dynamic seal and fixed seal design, reliable seal, and is equipped with pressure gauge in obvious position. It is a new generation of high voltage switchgear equipped with urban power grid for operation monitoring to ensure operation safety.
This product is suitable for three-phase AC 10KV, 50HZ power systems, industrial and mining enterprises, high-rise buildings, residential areas, pre-installed substation places, used to open and close the load current, fault current, control and protection lines and distribution transformers.

Use environmental conditions
Ambient temperature: -15ºC~+40ºC;
Altitude: no more than 1000m;
Relative humidity: the average value of daily relative humidity shall not exceed 95%, the average value of monthly relative
humidity shall not exceed 90%, the average value of daily water vapor pressure shall not exceed 2.2kPa, and the average value of monthly water vapor pressure shall not exceed More than 1.8 kPa;
The amplitude of electromagnetic interference induced in the secondary system shall not exceed 1.6kV.

| The name of the | units | data | ||
| FLN36-12D | FLRN36-12D | |||
| The rated voltage | 12 | 12 | ||
| Rated frequency | 50 / 60 | 50 / 60 | ||
| Rated current | A | 630 | 1250 | |
| Load switch rated short - term tolerance current/rated short - circuit duration | kA/S | 20/3 | - | |
| Ground switch rated short-time tolerance current/rated short-circuit duration | kA/S | 20/2 | - | |
| Rated peak tolerance current and rated short-circuit closing current | kA | 50 | 125 ( expect ) | |
| rated breaking current | Active load breaking current | A | 630 | - |
| Closed-loop breaking current | A | 630 | - | |
| 5% rated active load breaking current | A | 31.5 | - | |
| Turn off the cable charging current | A | 10 | - | |
| Turn off the no-load transformer capacity | KVA | 1250 | 1250 | |
| Turn off the transfer current | A | - | 1700 | |
| Expected short circuit breaking current | kA | - | 50 | |
| Rated insulation level | 1minl frequency withstand voltage phase, to ground/off | KV | 42/48 | 42/48 |
| Lightning shock withstand voltage phase, to ground/off | KV | 75/85 | 75/85 | |
| Mechanical life | 500 | 500 | ||
| SF6 rated air pressure (gauge pressure at 20°C)" | MPa | 0.04-0.05 | 0.04-0.05 | |
The technical parameters of the form are for reference only.