Welcome Customer !

Membership

XwbooWarehouse LogisticsCard ReaderUHF RFID ReaderSingle flange differential pressure transmitter
  • $item.Title
  • $item.Title

Single flange differential pressure transmitter

iangsu Zhongwei Measurement and Control Co., Ltd.

Model
Nature of the Manufacturer
Other
Product Category
UHF RFID Reader
Place of Origin
,

iangsu Zhongwei Measurement and Control Co., Ltd.

Contact

Phone

18852328848

Fax

0517-86918679
Single flange differential pressure transmitter
Description:

1, the structure:

Single flange level transmitter by differential pressure transmitter, capillary and belt of flange seal diaphragm.Seal diaphragm role is to prevent the pipe in the medium directly into the differential pressure transmitter, it is between the transmitter and by filling of liquid (usually use silicone oil) capillary connected, when diaphragm pressure to produce tiny deformation, deformation or frequency through capillary liquid is passed to the transmitter, the transmitter converts the output signal after processing.

2, appearance inspection:

A, flange check: check the flange connected to the equipment section of the seal are in good condition;Flange and capillary, capillary and itself if there is a connection part of the transmitter and capillary liquid leakage;Flange diaphragm deformation, damage, corrosion, scaling and other adverse conditions.

B, the transmitter inspection: check whether there is any damage, corrosion and other failure on transmitter shell, handle in time when problems found.

3, acceptance:

A, open the cover in the transmitter, check the sealing ring is damaged, if the damage to change in time;Check the circuit boards and other components are in good condition.

B, check the wiring of transmitter are in good condition.

C, disconnect the power supply, wire, insulation resistance checks, with a 500 v megohmmeter check transmitter terminals and shell, the insulation resistance between the resistance value should be greater than 20 m above.

4, single flange level transmitter to debug the check

In order to ensure that a measuring precision of the single flange level transmitter transmitter, cannot open capillary, so check to check with flange transmitter;Before installation, can use pneumatic analog signals and calibrate the HART com.

B, zero and span adjustment steps: zero and range of output, so that it is within the scope of permissible error.Continuous pressure, with the range of 0%, 25%, 50%, 75%, 150% of the pressure calibration, when pressure is stable after the record on the standard ammeter displays the current value and do return error checking.If calibration error exceeds permissible error range, should readjust the check.Adjusting method when operated by HART, see HART instructions accordingly.

4, installation:

A, far eastone flange installation:

High and low pressure on both sides of the flange should be installed correctly, can't put wrong;To reduce the influence of environment temperature difference, can be high and low voltage side of capillary bundle together, and fixed to prevent the wind and the influence of vibration and so on (super long section of the capillary volume in fixed together).Be careful not to damage the surface of the liquid membrane.Don't distort, extrusion capillary, don't put too much pressure to it.

B, the installation of transmitter ontology: use the installation bracket, the transmitter ontology is installed on the pipe diameter of 50 mm.Can be installed in horizontal pipe and the vertical piping installation.

5, note:

A, the four bolts fastening measuring capacitance room, connecting the capillary and let room part of the set screw must not loose, liquid sealed to prevent leaks, instrument damage.

B, wiring should avoid large capacity transformer, motor or power with power interference sources;Wiring should disconnect the power supply interface of dustproof plug;Thread department should undertake waterproof processing (waterproof processing is used when no hardening of silicone sealant series);To prevent interference, and other signal cable should avoid power cable through the same cable protection tube;For explosion-proof type instrument, in order to ensure the explosion-proof performance, must be in accordance with the relevant provisions of the wiring.

Eight, maintenance:

The following is our maintenance of flange transmitter is introduced.

1, occur during the winter freeze, when installed in the outdoor anti-freezing measures needed for transmitter, without pressure, fluid due to the icing volume expansion in the mouth, lead to the damage of sensors.

2, connection, cable through the waterproof connector (attachment) or round tube and screw down the sealing nut, such as in case of rain through the cable leakage into the transmitter inside the shell.

3, when measuring the pressure of the gas, apply pressure to open at the top of the process piping, flange level transmitter and also will be installed in the upper part of the process pipe so that the deposition of liquid pipelines of rapid injection to the process.

4, single flange level transmitter measuring steam or other high temperature medium, the need to connect with the buffer tube (coil) such as condenser, should not make the transmitter operating temperature more than limit.

5, pay attention to the pressure pipe of a sensor to install where small temperature fluctuations.

6, when measuring the liquid pressure, flange level transmitter installation location should avoid the impact of the fluid (water hammer), in order to avoid the sensor damage of overpressure.

7, when measuring the liquid pressure, pressure pipe side should be open in the process, in order to avoid precipitation product residue.

Eight, to prevent flange transmitter and corrosive or overheating medium contact, prevent the dross in intraductal deposition.

Nine, selection of code:

ZW3051LT

(work pressure 2.5 MPa) wei measurement and control of the ()


code

Scale range KPa

3

0-1.3 ~ 7.5

4

0-4-40

5

0 to 40 ~ 200

6

0-0.16-700


code

The output

E

4-20mA

S

Intelligent type (HART protocol)


code

Nominal diameter size (mm)

Insert tube length (mm)

High side diaphragm material

A0

(3), 80

flat

316LSST

A2

(3), 80

50

316LSST

A4

(3), 80

100

316LSST

A6

(3), 80

150

316LSST

B0

(4) 100

flat

316LSST

B2

(4) 100

50

316LSST

B4

(4) 100

100

316LSST

B6

(4) 100

150

316LSST

C0

(3), 80

flat

Hartz C - 276

C2

(3), 80

50

Hartz C - 276

C4

(3), 80

100

Hartz C - 276

C6

(3), 80

150

Hartz C - 276

D0

(4) 100

flat

Hartz C - 276

D2

(4) 100

50

Hartz C - 276

D4

(4) 100

100

Hartz C - 276

D6

(4) 100

150

Hartz C - 276

E0

(3), 80

flat

tantalum

F0

(4) 100

flat

tantalum


code

Installation of flange

A

3〞150lb

B

4〞150lb

C

3〞300lb

D

4〞300lb


code

Junction structure materials

Flange and joint

Vent/drain valve

Isolation diaphragm

Pump the liquid

22

316 stainless steel

316 stainless steel

316 stainless steel

Silicone oil

23

316 stainless steel

316 stainless steel

Hartz alloy C

24

316 stainless steel

316 stainless steel

monel

25

316 stainless steel

316 stainless steel

tantalum

33

Hartz alloy C

Hartz alloy C

Hartz alloy C

35

Hartz alloy C

Hartz alloy C

tantalum


code

options

M1

0-99% linear indicator

M2

LED display table

M3

LCD display table

B1

Bend tubes of stents

B2

Plate bending bracket

B3

Pipe bracket with flat

D1

The upper side discharge valve in the pressure chamber

D2

Lateral release valve at the bottom of the pressure chamber

Don't note

1/2 NPT taper pipe nipple

C2

Jump nipple M20 x 1.5, with the back of the welding Ф 14
System pressure tube ball cone head

d

Flameproof d Ⅱ BT4

i

The Ann type ia Ⅱ CT6


iangsu Zhongwei Measurement and Control Co., Ltd. is located in Huaian City, the hometown of Premier Zhou, a great man of one generation. It has beautiful scenery, pleasant climate and abundant products. Main Products: Main Products: Intelligent Vortex Street Flowmeter, Intelligent Electromagnetic Flowmeter, Liquid Turbine Flowmeter, Elliptical Gear Flowmeter, Universal Electronic Flowmeter, Magnetoelectricity Flowmeter, Swirl Flowmeter, Metal Tube Float Meter, Wilba Flowmeter, Delta Bar Flowmeter, Orifice Flowmeter, Balanced Flowmeter, Air Measuring Device, Heat Meter, Ultrasound Flow Meter Meters, magneto-sensitive electronic double-color liquid level gauge, boiler drum level gauge, mica double-color water level gauge, radar level gauge, ultrasonic level gauge, magnetic turning plate level gauge, level (level) switch, pressure differential pressure transmitter, thermometer, thermoresistor, thermocouple, display, recorder, calibration equipment, wire and cable, control valve, etc. Professional R&D and sales of industrial automation products, providing integrated technical services of industrial automation system, is a comprehensive industrial automation product R&D and technology enterprise in China, which is built and developed at the beginning of the industry scale.The company's quality assurance system is complete. The company has a number of high-tech professionals engaged in the design, development, installation and commissioning of automation control research for a long time, which provides a satisfactory set of systems for various industries. It gathers strong professional team, accumulates abundant technology and management experience, covers the national marketing network and branches, and can provide users with technical services quickly and conveniently. In the era of Internet commerce, the company has set up the E-Commerce Department, relying on professional network technology and e-commerce trade means, to implement the integration of traditional economy and resources as well as rapid market expansion in a wide range. Since its establishment, the company has established a long-term and stable business and trade partnership with manufacturers in various regions by virtue of its good reputation and high-quality service.In line with the business philosophy of "satisfying customer's needs and creating value for customers", we have provided a large number of complete sets of services for users in oil field, power, chemical industry, metallurgy, paper-making, cement and other industries for many years to improve more seamless services for our customers. You can purchase online, learn business knowledge independently, serve your customers better, and create more value for you for five consecutive years. Our products are sold overseas, and we have distribution agents in many regions to further increase domestic marketing and expand the brand of Zhongwei. From 2011, we will recruit agents and distribute in the whole country. We can also provide OEM services for you. The quality service is consistent with that of Jiangsu Zhongwei. We promise you the best quality, the best service and the best price!The company adheres to the development policy of "science and technology, innovation, quality and service", continues to adhere to the purpose of "building an industrial aircraft carrier and contributing to the national economy". In the future development, it will continue to devote itself to brand building and constantly cultivate new economic growth points. Jiangsu Zhongwei will actively participate in market competition with high-quality products, preferential prices and excellent services, and wholeheartedly participate in friends from all walks of life. Friends, old and new customers cooperate in good faith, work hand in hand with Zhongwei measurement and control, create a better tomorrow.