Membership
Help
COTRUST TECHNOLOGIES CO., LTD.
COTRUST TECHNOLOGIES CO., LTD.
Order Data
| Order Data | Order No. |
| Six-channel weighing transducer,16Bit,6 sensor signal input, 6VDC excitation power output, isolation 16 bit accuracy | CTH2 231-7WF32 |
Performance Parameters
Order no. | CTH2 231-7WF32 |
Channel number | 6 |
Sampling frequency | 50Hz |
Internal resolution | 65535(16bits) |
Weight value data format | 2 byte |
Applicable CPU type | CTH200,CTMC series |
Power from the CPU bus | |
+5V current consumption | <80mA |
24 V Power supply | |
Rated voltage | DC 24 V |
Voltage range | DC 20.4~28.8V |
Maximum current consumption | 100mA |
Typical power consumption | 2.4W |
LED diagnose | |
LED Indicator | +24VDC: On = 24VDC power supply normal, Off = no 24VDC power supply SF: Flicker = Sensor disconnection, Off = No Error |
Configurable filter | |
The limiting frequency of the low pass filter | 0.05Hz、0.1Hz、0.2Hz、0.5Hz 、1Hz、2Hz、5Hz |
Average filter | 0~150 |
Isolation characteristics | |
Site to logic | 500VAC |
Site to 24VDC | 500VAC |
24V to logic | 500VAC |
Common mode rejection | >120dB@120VAC |
Interference suppression | |
Noise suppression | 85dB@50Hz/60Hz |
Connection of weight sensor | |
Connection | Only 4-wire full bridge strain gauge is supported |
Length of lead to sensor | Maximum 50 m |
Error | |
Full-scale error limit (at 20℃±10℃) | ≤0.1% |
Sensitivity temperature coefficient | ≤±20ppm/K v. E |
Zero temperature coefficient | ≤±0.1uV/K |
Basic error | 0.05%FS |
Linear error | ≤0.01%FS |
Measuring range | 0~1mV/V;0~2mV/V;0~4mV/V |
Weighing sensor power supply Voltage Current(max) | Typical DC 6V 150mA |
Allowable resistance value of weighing sensor Explosion-free connection Explosion-proof connection | >40Ω,<4010Ω >87Ω,<4010Ω |
Common mode suppression CMRR@50/60Hz | Typical 80dB |
Insulation | 500V DC |
The information of the 7WF module is identified as 8AI/2AQ. For example, if the module is attached to the first slot of the CPU, the corresponding address information is as follows
AIW0 | AIW2 | AIW4 | AIW6 | AIW8 |
The first way data | The second-way data | The third-way data | The fourth-way data | The fifth-way data |
AIW10 | AIW12 | AIW14 | AQW0 | AQW2 |
The sixth-way data | Reserved, not available | Reserved, not available | Configuration data 1 | Configuration data 2 |
SM231-7WF is the size of large module. The installation size is shown in the figure.

Wiring diagram of the weighing module SM231-7WF