Thermal Fuse For Fan

JAYE HEATER TECHNOLOGY

Model
Nature of the Manufacturer
Manufacturer
Product Category
Temperature Sensor
Place of Origin
GuangDong, HuiZhou
Thermal Fuse For Fan

Thermal fuse for fan is installed on the outer wall of the winding of the motor. When the fan works, the motor will have a temp rise. It can only be installed on the outer wall of the motor winding, that is, close to the motor winding, to feel the actual temp of the motor, and play the role of protection. The application of its efficient and convenient features in electric heaters is more and more favored by R&D engineers and people inside and outside the industry!

 fuse drawing

Features:

It will fuse when the temp reaches its nominal value, thereby protecting the equipment from fire due to excessive temp.

A positive thermistor has a higher resistance value as the temp rises, but it will not blow. (A self-recovery fuse is one of them). However, ordinary thermistors cannot replace thermal fuses because they do not pass current. allow.

 Operation of Thermal Fuse

Installation Precautions of Thermal fuse for fan:

1. When the lead wire is used for bending, it should be bent from the part more than 3 mm away from the root; when bending, the root and lead wire should not be damaged, and the lead wire should not be forcibly pulled, pressed or twisted to prevent damage to the lead wire and the housing body.

2. When the thermal fuse is fixed by screws, riveting or terminal, it should be able to prevent mechanical creep from causing poor product contact.

3. The connecting parts should be able to work reliably within the working range of electrical products without displacement due to vibration or impact.

4. During the lead welding operation, the heating humidity should be limited to a small amount, and high temp should not be applied to the thermal fuse; the thermal fuse and lead should not be forced to be pulled, pressed or twisted; after the welding is completed, it should be immediately cooled for more than 30 seconds.In the event of false welding or missing welding, you need to perform welding again after the temp of the body drops, and do not contact for work.

5. The thermal fuse can only be used under the specified rated voltage, current and specified temp. Pay special attention to the temp that the thermal fuse can withstand continuously.

Remarks: The nominal current, lead length and temp can be designed according to customer requirements.

size list -1Size List-2


Hot Tags: thermal fuse for fan, China, manufacturers, suppliers, factory, wholesale, custom, price, electric, high quality

Application of Thermal Fuse


Packing & Delivery

Quality-Thermostat

  Jaye Heater Technology has been in the heating elements industry since 2009, After more than ten years of hard working and development, We have been growing up to 5 production plants, the production workshop has grown up to more than 28000 square meters, we has developed to more than 450 employees totally. more than 25 product engineers, and we have more than 280 production equipment and more than 90 professional testing equipment and instruments. Our product quality and production capacity have been in the forefront of the industry. Now we are one of the most trust worthy and professional OEM and a high-tech enterprise specializing in the research, development, manufacture, sales and service of domestic and industrial electric heating components and element, thermocouple and thermostats and spare parts in China.